You are on page 1of 7

Version 7.4.

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: Ejemplo D2
Variant: Nueva variante de simulación
Standalone system with batteries
System power: 330 Wp

PVsyst TRIAL
Estancia "La cueva del oso" - Bolivia

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Ejemplo D2
Variant: Nueva variante de simulación

PVsyst V7.4.2
VC0, Simulation date:
13/09/23 19:12

PVsyst TRIAL
with v7.4.2

Project summary
Geographical Site Situation Project settings
Estancia "La cueva del oso" Latitude -17.59 °S Albedo 0.20
Bolivia Longitude -63.40 °W
Altitude 373 m
Time zone UTC-4

Meteo data
Estancia "La cueva del oso"
Meteonorm 8.1 (2010-2017), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 16 / -20 ° Constant over the year
Average 1.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 1 unit Technology Lead-acid, sealed, Gel
Pnom total 330 Wp Nb. of units 1 unit
Voltage 12 V
Capacity 150 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 369.06 kWh/year
Missing Energy
Excess (unused)
4.70 kWh/year
175.38 kWh/year

Project and results summary


Specific production 1118 kWh/kWp/year Perf. Ratio PR
Available solar energy 566.15 kWh/year

Table of contents
Solar Fraction SF
53.62 %
98.74 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
13/09/23 PVsyst Evaluation mode Page 2/7
Project: Ejemplo D2
Variant: Nueva variante de simulación

PVsyst V7.4.2
VC0, Simulation date:
13/09/23 19:12

PVsyst TRIAL
with v7.4.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 16 / -20 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 1.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 330 Wp
PV Array Characteristics

Generic
AE 330MB-60
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
MPG 12V 150 F
Lead-acid, sealed, Gel
1 Unit
Number of PV modules 1 unit Discharging min. SOC 20.0 %
Nominal (STC) 330 Wp Stored energy 1.5 kWh
Modules 1 String x 1 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 12 V
Pmpp 299 Wp Nominal Capacity 150 Ah (C10)
U mpp 31 V Temperature Fixed 20 °C
I mpp 9.8 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.90 / 0.75
13.5 / 12.7 V
SOC = 0.20 / 0.45
11.8 / 12.3 V

Total PV power
Nominal (STC) 0.330 kWp
Total 1 modules
Module area 1.7 m²
Cell area 1.5 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.8 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
52 mΩ
1.5 % at STC

0.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction
0.7 V
2.1 % at STC

IAM loss factor


Incidence effect (IAM): Fresnel, AR coating, n(glass)=1.526, n(AR)=1.290

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000

PVsyst TRIAL
13/09/23 PVsyst Evaluation mode Page 3/7
Project: Ejemplo D2
Variant: Nueva variante de simulación

PVsyst V7.4.2
VC0, Simulation date:
13/09/23 19:12

PVsyst TRIAL
with v7.4.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 1.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
Lámparas (LED o fluo) 5 11/lamp 8.0 440
TV / PC / móvil 1 75/app 6.0 450
Celular 1 15 tot 4.0 60
Radio 1 50 tot 1.0 50
Consumidores en espera 24.0 24
Total daily energy 1024

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
13/09/23 PVsyst Evaluation mode Page 4/7
Project: Ejemplo D2
Variant: Nueva variante de simulación

PVsyst V7.4.2
VC0, Simulation date:
13/09/23 19:12

PVsyst TRIAL
with v7.4.2

Main results
System Production
Useful energy from solar 369.06 kWh/year Perf. Ratio PR 53.62 %
Available solar energy 566.15 kWh/year Solar Fraction SF 98.74 %
Excess (unused) 175.38 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 2.3 % Cycles SOW 81.2 %
Missing Energy 4.70 kWh/year Static SOW 91.7 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
204.2
176.1
189.7
160.6
GlobEff
kWh/m²
188.0
169.0
191.0
173.1
E_Avail
kWh
51.28
46.45
52.37
48.21
EUnused
kWh
18.40
16.36
19.23
15.64
E_Miss
kWh
0.581
0.335
0.435
0.000
E_User
kWh
31.16
28.34
31.31
30.72
E_Load
kWh
31.74
28.67
31.74
30.72
SolFrac
ratio
0.982
0.988
0.986
1.000
May 142.8 162.3 45.88 12.25 0.000 31.74 31.74 1.000
June 123.2 144.0 41.20 10.21 1.287 29.43 30.72 0.958
July 134.3 155.4 44.22 10.84 0.148 31.60 31.74 0.995
August 143.6 158.3 44.12 11.94 1.597 30.15 31.74 0.950
September 159.0 163.5 45.16 12.73 0.033 30.69 30.72 0.999
October 184.5 180.1 49.29 15.65 0.000 31.74 31.74 1.000
November 187.9 174.2 47.92 15.64 0.286 30.43 30.72 0.991

PVsyst TRIAL
December 199.8 180.8 50.04 16.48 0.000 31.74 31.74 1.000
Year 2005.6 2039.7 566.15 175.38 4.702 369.06 373.76 0.987

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
13/09/23 PVsyst Evaluation mode Page 5/7
Project: Ejemplo D2
Variant: Nueva variante de simulación

PVsyst V7.4.2
VC0, Simulation date:
13/09/23 19:12

PVsyst TRIAL
with v7.4.2

Loss diagram
2006 kWh/m² Global horizontal irradiation
+4.0% Global incident in coll. plane

-2.20% IAM factor on global

2040 kWh/m² * 2 m² coll. Effective irradiation on collectors

efficiency at STC = 19.90% PV conversion

673 kWh Array nominal energy (at STC effic.)

PVsyst TRIAL
-0.64% PV loss due to irradiance level

-10.27% PV loss due to temperature

+0.75% Module quality loss

0.00% Module array mismatch loss

-3.45% Ohmic wiring loss

-30.04% Unused energy (battery full)

408 kWh Effective energy at the output of the array

PVsyst TRIAL
Missing
391 kWh
-4.25%
-0.06%
0.00%
0.00%
Converter Loss during operation (efficiency)
Converter Loss due to power threshold
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
Converter losses (effic, overload)
Direct use Stored Battery Storage
energy 8.7% 91.3%
-0.06% Battery Stored Energy balance
1.26%
-4.59% Battery efficiency loss
4.7 kWh
-2.60% Charge/Disch. Current Efficiency Loss
-0.09% Gassing Current (electrolyte dissociation)
-0.17% Battery Self-discharge Current

PVsyst TRIAL 369 kWh

374 kWh
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
13/09/23 PVsyst Evaluation mode Page 6/7
Project: Ejemplo D2
Variant: Nueva variante de simulación

PVsyst V7.4.2
VC0, Simulation date:
13/09/23 19:12

PVsyst TRIAL
with v7.4.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
13/09/23 PVsyst Evaluation mode Page 7/7

You might also like