You are on page 1of 7

Version 7.2.

21

PVsyst TRIAL
PVsyst - Simulation report
Stand alone system

Project: Presentation
Variant: New simulation variant
Stand alone system with batteries
System power: 1200 Wp

PVsyst TRIAL Mol - Cambodia

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Presentation
Variant: New simulation variant

PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17

PVsyst TRIAL
with v7.2.21

Project summary
Geographical Site Situation Project settings
Mol Latitude 11.52 °N Albedo 0.20
Cambodia Longitude 104.88 °E
Altitude 4m
Time zone UTC+7

Meteo data
Mol
Meteonorm 8.0 (1996-2015), Sat=100% - Synthetic

System summary

PVsyst TRIAL
Stand alone system Stand alone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 4.1 kWh/Day

System information
PV Array Battery pack
Nb. of modules 4 units Technology Lead-acid, vented, plates
Pnom total 1200 Wp Nb. of units 16 units
Voltage 48 V
Capacity 400 Ah

Results summary

PVsyst TRIAL
Available Energy
Used Energy
1693 kWh/year
1478 kWh/year

Project and results summary


Specific production 1411 kWh/kWp/year Perf. Ratio PR

Table of contents

General parameters, PV Array Characteristics, System losses


Solar Fraction SF
69.34 %
98.30 %

2
3
Detailed User's needs 4
Main results 5
Loss diagram 6
Special graphs 7

PVsyst TRIAL

PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 2/7
Project: Presentation
Variant: New simulation variant

PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17

PVsyst TRIAL
with v7.2.21

General parameters
Stand alone system Stand alone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 4.1 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 300 Wp
PV Array Characteristics

Generic
Mono 300 Wp 60 cells
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
Open 12V / 100 Ah
Lead-acid, vented, plates
4 in parallel x 4 in series
Number of PV modules 4 units Discharging min. SOC 20.0 %
Nominal (STC) 1200 Wp Stored energy 15.4 kWh
Modules 4 Strings x 1 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 1080 Wp Nominal Capacity 400 Ah (C10)
U mpp 28 V Temperature Fixed 20 °C
I mpp 38 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
53.3 / 49.5 V
SOC = 0.20 / 0.45
46.5 / 48.3 V

Total PV power
Nominal (STC) 1.20 kWp
Total 4 modules
Module area 6.5 m²
Cell area 5.7 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.8 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
13 mΩ
1.5 % at STC

0.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
2.2 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel, AR coating, n(glass)=1.526, n(AR)=1.290

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000

PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 3/7
Project: Presentation
Variant: New simulation variant

PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17

PVsyst TRIAL
with v7.2.21

Detailed User's needs


Daily household consumers, Constant over the year, average = 4.1 kWh/day
Annual values Hourly distribution

Number Power Use Energy


W Hour/day Wh/day
Lamps (LED or fluo) 10 25W/lamp 5.0 1250
Lap top 1 50W/app 1.0 50
Domestic appliances 1 200W/app 2.0 400
Fridge / Deep-freeze 1 24 151
Cloth-washer 1 1 550
Fan 1 55W tot 9.0 495

PVsyst TRIAL
Kettle 1 1200W tot 1.0 1200
Stand-by consumers 24.0 24
Total daily energy 4120Wh/day

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 4/7
Project: Presentation
Variant: New simulation variant

PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17

PVsyst TRIAL
with v7.2.21

Main results
System Production
Available Energy 1693 kWh/year Specific production 1411 kWh/kWp/year
Used Energy 1478 kWh/year Performance Ratio PR 69.34 %
Excess (unused) 122 kWh/year Solar Fraction SF 98.30 %
Loss of Load Battery aging (State of Wear)
Time Fraction 1.9 % Cycles SOW 97.5 %
Missing Energy 26 kWh/year Static SOW 90.0 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
121.2
123.8
159.0
173.0
GlobEff
kWh/m²
130.7
129.4
159.6
164.4
E_Avail
kWh
128.0
125.8
153.6
159.4
EUnused
kWh
0.00
3.48
11.67
22.48
E_Miss
kWh
4.67
0.00
0.00
0.00
E_User
kWh
123.1
115.4
127.7
123.6
E_Load
kWh
127.7
115.4
127.7
123.6
SolFrac
ratio
0.963
1.000
1.000
1.000
May 167.8 151.8 147.1 14.33 0.00 127.7 127.7 1.000
June 168.3 148.8 145.7 13.55 0.00 123.6 123.6 1.000
July 168.8 151.4 148.3 10.43 0.00 127.7 127.7 1.000
August 159.7 148.9 145.1 8.08 0.00 127.7 127.7 1.000
September 145.1 141.7 139.0 9.33 0.00 123.6 123.6 1.000
October 158.2 163.6 160.5 23.70 0.00 127.7 127.7 1.000
November 115.7 122.0 120.6 4.54 7.80 115.8 123.6 0.937

PVsyst TRIAL
December 112.2 120.9 119.7 0.00 13.15 114.6 127.7 0.897
Year 1773.0 1733.1 1692.8 121.60 25.62 1478.3 1503.9 0.983

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 5/7
Project: Presentation
Variant: New simulation variant

PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17

PVsyst TRIAL
with v7.2.21

Loss diagram
1773 kWh/m² Global horizontal irradiation
+0.2% Global incident in coll. plane

-2.45% IAM factor on global

1733 kWh/m² * 7 m² coll. Effective irradiation on collectors

efficiency at STC = 18.45% PV conversion

2081 kWh Array nominal energy (at STC effic.)

PVsyst TRIAL
-0.72% PV loss due to irradiance level

-11.95% PV loss due to temperature

+0.75% Module quality loss

-0.10% Mismatch loss, modules and strings

-3.57% Ohmic wiring loss

-6.89% Unused energy (battery full)

1644 kWh Effective energy at the output of the array

PVsyst TRIAL
-4.39% Converter Loss during operation (efficiency)

-0.03% Converter Loss due to power threshold


0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
1571 kWh Converter losses (effic, overload)
Missing Direct use Stored Battery Storage
energy 38.7% 61.3%
-0.30% Battery Stored Energy balance
1.70% -5.21% Battery efficiency loss
25.6 kWh
-1.87% Charge/Disch. Current Efficiency Loss

-0.40% Gassing Current (electrolyte dissociation)


-0.46% Battery Self-discharge Current

PVsyst TRIAL 1478 kWh

1504 kWh
Energy supplied to the user

Energy need of the user (Load)

PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 6/7
Project: Presentation
Variant: New simulation variant

PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17

PVsyst TRIAL
with v7.2.21

Special graphs
Daily Input/Output diagram

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 7/7

You might also like