PVsyst TRIAL
PVsyst - Simulation report
Stand alone system
Project: Presentation
Variant: New simulation variant
Stand alone system with batteries
System power: 1200 Wp
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: Presentation
Variant: New simulation variant
PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17
PVsyst TRIAL
with v7.2.21
Project summary
Geographical Site Situation Project settings
Mol Latitude 11.52 °N Albedo 0.20
Cambodia Longitude 104.88 °E
Altitude 4m
Time zone UTC+7
Meteo data
Mol
Meteonorm 8.0 (1996-2015), Sat=100% - Synthetic
System summary
PVsyst TRIAL
Stand alone system Stand alone system with batteries
System information
PV Array Battery pack
Nb. of modules 4 units Technology Lead-acid, vented, plates
Pnom total 1200 Wp Nb. of units 16 units
Voltage 48 V
Capacity 400 Ah
Results summary
PVsyst TRIAL
Available Energy
Used Energy
1693 kWh/year
1478 kWh/year
Table of contents
2
3
Detailed User's needs 4
Main results 5
Loss diagram 6
Special graphs 7
PVsyst TRIAL
PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 2/7
Project: Presentation
Variant: New simulation variant
PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17
PVsyst TRIAL
with v7.2.21
General parameters
Stand alone system Stand alone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
User's needs
Daily household consumers
Constant over the year
Average 4.1 kWh/Day
PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 300 Wp
PV Array Characteristics
Generic
Mono 300 Wp 60 cells
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
Open 12V / 100 Ah
Lead-acid, vented, plates
4 in parallel x 4 in series
Number of PV modules 4 units Discharging min. SOC 20.0 %
Nominal (STC) 1200 Wp Stored energy 15.4 kWh
Modules 4 Strings x 1 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 1080 Wp Nominal Capacity 400 Ah (C10)
U mpp 28 V Temperature Fixed 20 °C
I mpp 38 A
PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.
97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.92 / 0.75
53.3 / 49.5 V
SOC = 0.20 / 0.45
46.5 / 48.3 V
Total PV power
Nominal (STC) 1.20 kWp
Total 4 modules
Module area 6.5 m²
Cell area 5.7 m²
Array losses
PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)
-0.8 %
DC wiring losses
Global array res.
Loss Fraction
0.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction
0.1 %
PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 3/7
Project: Presentation
Variant: New simulation variant
PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17
PVsyst TRIAL
with v7.2.21
PVsyst TRIAL
Kettle 1 1200W tot 1.0 1200
Stand-by consumers 24.0 24
Total daily energy 4120Wh/day
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 4/7
Project: Presentation
Variant: New simulation variant
PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17
PVsyst TRIAL
with v7.2.21
Main results
System Production
Available Energy 1693 kWh/year Specific production 1411 kWh/kWp/year
Used Energy 1478 kWh/year Performance Ratio PR 69.34 %
Excess (unused) 122 kWh/year Solar Fraction SF 98.30 %
Loss of Load Battery aging (State of Wear)
Time Fraction 1.9 % Cycles SOW 97.5 %
Missing Energy 26 kWh/year Static SOW 90.0 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
121.2
123.8
159.0
173.0
GlobEff
kWh/m²
130.7
129.4
159.6
164.4
E_Avail
kWh
128.0
125.8
153.6
159.4
EUnused
kWh
0.00
3.48
11.67
22.48
E_Miss
kWh
4.67
0.00
0.00
0.00
E_User
kWh
123.1
115.4
127.7
123.6
E_Load
kWh
127.7
115.4
127.7
123.6
SolFrac
ratio
0.963
1.000
1.000
1.000
May 167.8 151.8 147.1 14.33 0.00 127.7 127.7 1.000
June 168.3 148.8 145.7 13.55 0.00 123.6 123.6 1.000
July 168.8 151.4 148.3 10.43 0.00 127.7 127.7 1.000
August 159.7 148.9 145.1 8.08 0.00 127.7 127.7 1.000
September 145.1 141.7 139.0 9.33 0.00 123.6 123.6 1.000
October 158.2 163.6 160.5 23.70 0.00 127.7 127.7 1.000
November 115.7 122.0 120.6 4.54 7.80 115.8 123.6 0.937
PVsyst TRIAL
December 112.2 120.9 119.7 0.00 13.15 114.6 127.7 0.897
Year 1773.0 1733.1 1692.8 121.60 25.62 1478.3 1503.9 0.983
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 5/7
Project: Presentation
Variant: New simulation variant
PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17
PVsyst TRIAL
with v7.2.21
Loss diagram
1773 kWh/m² Global horizontal irradiation
+0.2% Global incident in coll. plane
PVsyst TRIAL
-0.72% PV loss due to irradiance level
PVsyst TRIAL
-4.39% Converter Loss during operation (efficiency)
1504 kWh
Energy supplied to the user
PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 6/7
Project: Presentation
Variant: New simulation variant
PVsyst V7.2.21
VC0, Simulation date:
05/12/23 16:17
PVsyst TRIAL
with v7.2.21
Special graphs
Daily Input/Output diagram
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
05/12/23 PVsyst Evaluation mode Page 7/7