You are on page 1of 8

Version 7.3.

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: SUCUMBIOS
Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3520 Wp

PVsyst TRIAL Shushufindi - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: SUCUMBIOS
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
Shushufindi Latitude -0.19 °S Albedo 0.20
Ecuador Longitude -76.65 °W
Altitude 242 m
Time zone UTC-5

Meteo data
Shushufindi
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 11.6 kWh/Day

System information
PV Array Battery pack
Nb. of modules 22 units Technology Lithium-ion, NCA
Pnom total 3520 Wp Nb. of units 4 units
Voltage 50 V
Capacity 1072 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 4222.90 kWh/year
Missing Energy
Excess (unused)
0.00 kWh/year
604.19 kWh/year

Project and results summary


Specific production 1200 kWh/kWp/year Perf. Ratio PR
Available solar energy 5010.34 kWh/year

Table of contents
Solar Fraction SF
67.58 %
100.00 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7
Cost of the system 8

PVsyst TRIAL

PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 2/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 11.6 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 160 Wp
PV Array Characteristics

Generic
TSM-160PEG40.07
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
Powerwall2
Lithium-ion, NCA
4 in parallel
Number of PV modules 22 units Discharging min. SOC 10.0 %
Nominal (STC) 3520 Wp Stored energy 49.0 kWh
Modules 11 Strings x 2 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 50 V
Pmpp 3159 Wp Nominal Capacity 1072 Ah (C10)
U mpp 36 V Temperature Fixed 20 °C
I mpp 89 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 3.52 kWp
Total 22 modules
Module area 36.2 m²
Cell area 21.4 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.7 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
6.7 mΩ
1.5 % at STC

0.6 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
1.8 % at STC

0.1 %

IAM loss factor


ASHRAE Param.: IAM = 1 - bo (1/cosi -1)
bo Param. 0.05

PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 3/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 11.6 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
Lámparas 10 60/lamp 7.0 4200
focos florecentes 3 40/app 8.0 960
laptos 2 45/app 5.0 450
Nevera 1 24 10
lavadora 1 2 450
television 1 80 tot 5.0 400

PVsyst TRIAL
plancha 1 200 tot 1.5 300
Consumidores en espera 24.0 4800
Total daily energy 11570

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 4/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 4222.90 kWh/year Performance Ratio PR 67.58 %
Available solar energy 5010.34 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 604.19 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 93.7 %
Missing Energy 0.00 kWh/year Static SOW 90.0 %
Battery lifetime 10.0 years

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL

PVsyst TRIAL
Balances and main results

GlobHor GlobEff E_Avail EUnused E_Miss E_User E_Load SolFrac


kWh/m² kWh/m² kWh kWh kWh kWh kWh ratio
January 159.7 135.2 391.9 10.0 0.000 358.7 358.7 1.000
February 138.5 123.8 361.8 29.0 0.000 323.9 323.9 1.000
March 155.3 146.2 423.1 54.2 0.000 358.7 358.7 1.000
April 154.6 154.4 443.9 66.5 0.000 347.1 347.1 1.000
May 161.3 168.3 487.1 115.4 0.000 358.7 358.7 1.000
June 148.8 158.7 460.2 103.1 0.000 347.1 347.1 1.000
July 147.7 155.3 453.4 74.8 0.000 358.7 358.7 1.000
August 142.5 143.9 417.3 44.7 0.000 358.7 358.7 1.000
September 150.1 144.5 421.7 61.2 0.000 347.1 347.1 1.000
October 149.9 136.8 399.3 25.7 0.000 358.7 358.7 1.000

PVsyst TRIAL
November 143.6 124.3 367.2 12.5 0.000 347.1 347.1 1.000
December 155.0 130.9 383.5 7.1 0.000 358.7 358.7 1.000
Year 1806.9 1722.2 5010.3 604.2 0.000 4222.9 4222.9 1.000

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 5/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23

PVsyst TRIAL
with v7.3.2

Loss diagram
1807 kWh/m² Global horizontal irradiation

-1.75% Global incident in coll. plane

-2.99% IAM factor on global

1722 kWh/m² * 36 m² coll. Effective irradiation on collectors

efficiency at STC = 9.73% PV conversion

6064 kWh Array nominal energy (at STC effic.)

PVsyst TRIAL
-0.23% PV loss due to irradiance level

-11.14% PV loss due to temperature

+0.72% Module quality loss

-0.70% Mismatch loss, modules and strings

-3.00% Ohmic wiring loss

-11.58% Unused energy (battery full)

4612 kWh Effective energy at the output of the array

PVsyst TRIAL
-4.41% Converter Loss during operation (efficiency)

-0.05% Converter Loss due to power threshold


0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
4406 kWh Converter losses (effic, overload)
Missing
Direct use Stored Battery Storage
energy 36.8% 63.2%
+0.01% Battery Stored Energy balance
0.00%
0.0 kWh
-3.15% Battery efficiency loss

-2.45% Charge/Disch. Current Efficiency Loss

-0.83% Battery Self-discharge Current

PVsyst TRIAL
4223 kWh Energy supplied to the user

4223 kWh Energy need of the user (Load)

PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 6/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 7/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23

PVsyst TRIAL
with v7.3.2

Cost of the system


Installation costs

Item Quantity Cost Total


units EUR EUR
Total 0.00
Depreciable asset 0.00

Operating costs

Item Total

PVsyst TRIAL
EUR/year
Total (OPEX) 0.00

System summary
Total installation cost 0.00 EUR
Operating costs 0.00 EUR/year
Excess energy (battery full) 604 kWh/year
Used solar energy 4223 kWh/year
Used energy cost 0.000 EUR/kWh

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 8/8

You might also like