Professional Documents
Culture Documents
PVsyst TRIAL
PVsyst - Simulation report
Standalone system
Project: SUCUMBIOS
Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3520 Wp
PVsyst TRIAL
PVsyst TRIAL
Autor(a)
PVsyst TRIAL
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23
PVsyst TRIAL
with v7.3.2
Project summary
Geographical Site Situation Project settings
Shushufindi Latitude -0.19 °S Albedo 0.20
Ecuador Longitude -76.65 °W
Altitude 242 m
Time zone UTC-5
Meteo data
Shushufindi
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético
System summary
PVsyst TRIAL
Standalone system Standalone system with batteries
System information
PV Array Battery pack
Nb. of modules 22 units Technology Lithium-ion, NCA
Pnom total 3520 Wp Nb. of units 4 units
Voltage 50 V
Capacity 1072 Ah
Results summary
PVsyst TRIAL
Useful energy from solar 4222.90 kWh/year
Missing Energy
Excess (unused)
0.00 kWh/year
604.19 kWh/year
Table of contents
Solar Fraction SF
67.58 %
100.00 %
2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7
Cost of the system 8
PVsyst TRIAL
PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 2/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23
PVsyst TRIAL
with v7.3.2
General parameters
Standalone system Standalone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
User's needs
Daily household consumers
Constant over the year
Average 11.6 kWh/Day
PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 160 Wp
PV Array Characteristics
Generic
TSM-160PEG40.07
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
Powerwall2
Lithium-ion, NCA
4 in parallel
Number of PV modules 22 units Discharging min. SOC 10.0 %
Nominal (STC) 3520 Wp Stored energy 49.0 kWh
Modules 11 Strings x 2 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 50 V
Pmpp 3159 Wp Nominal Capacity 1072 Ah (C10)
U mpp 36 V Temperature Fixed 20 °C
I mpp 89 A
PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.
97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35
Total PV power
Nominal (STC) 3.52 kWp
Total 22 modules
Module area 36.2 m²
Cell area 21.4 m²
Array losses
PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)
-0.7 %
DC wiring losses
Global array res.
Loss Fraction
0.6 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction
0.1 %
PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 3/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23
PVsyst TRIAL
with v7.3.2
PVsyst TRIAL
plancha 1 200 tot 1.5 300
Consumidores en espera 24.0 4800
Total daily energy 11570
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 4/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23
PVsyst TRIAL
with v7.3.2
Main results
System Production
Useful energy from solar 4222.90 kWh/year Performance Ratio PR 67.58 %
Available solar energy 5010.34 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 604.19 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 93.7 %
Missing Energy 0.00 kWh/year Static SOW 90.0 %
Battery lifetime 10.0 years
PVsyst TRIAL
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
November 143.6 124.3 367.2 12.5 0.000 347.1 347.1 1.000
December 155.0 130.9 383.5 7.1 0.000 358.7 358.7 1.000
Year 1806.9 1722.2 5010.3 604.2 0.000 4222.9 4222.9 1.000
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 5/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23
PVsyst TRIAL
with v7.3.2
Loss diagram
1807 kWh/m² Global horizontal irradiation
PVsyst TRIAL
-0.23% PV loss due to irradiance level
PVsyst TRIAL
-4.41% Converter Loss during operation (efficiency)
PVsyst TRIAL
4223 kWh Energy supplied to the user
PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 6/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23
PVsyst TRIAL
with v7.3.2
Predef. graphs
Diagrama entrada/salida diaria
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 7/8
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.3.2
VC0, Simulation date:
18/02/23 18:23
PVsyst TRIAL
with v7.3.2
Operating costs
Item Total
PVsyst TRIAL
EUR/year
Total (OPEX) 0.00
System summary
Total installation cost 0.00 EUR
Operating costs 0.00 EUR/year
Excess energy (battery full) 604 kWh/year
Used solar energy 4223 kWh/year
Used energy cost 0.000 EUR/kWh
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
18/02/23 PVsyst Evaluation mode Page 8/8