Version 7.4.

PVsyst - Simulation report


Standalone system

Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN "PID" PARQUE SDA


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 2700 Wp
Localidad Usme - Colombia
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
with v7.4.0

Project summary
Geographical Site Situation Project settings
Localidad Usme Latitude 4.51 °N Albedo 0.20
Colombia Longitude -74.10 °W
Altitude 2835 m
Time zone UTC-5

Meteo data
Localidad Usme
NASA-SSE satellite data 1983-2005 - Sintético

System summary
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 10 / 0 ° Constant over the year
Average 7.3 kWh/Day

System information
PV Array Battery pack
Nb. of modules 6 units Technology Lead-acid, sealed, Gel
Pnom total 2700 Wp Nb. of units 10 units
Voltage 24 V
Capacity 1250 Ah

Results summary
Useful energy from solar 369.62 kWh/year Specific production 137 kWh/kWp/year Perf. Ratio PR 7.78 %
Missing Energy 2305.10 kWh/year Available solar energy 464.07 kWh/year 13.82 %
Excess (unused) 0.00 kWh/year

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

P
08/07/23 Page 2/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
with v7.4.0

Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 10 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 7.3 kWh/Day

PV Array Characteristics
PV module Battery
Manufacturer Generic Manufacturer Generic
Model RSM-144-7-440-M Model Bateria Gel 12V 250 Ah
(Custom parameters definition) Technology Lead-acid, sealed, Gel
Unit Nom. Power 450 Wp Nb. of units 5 in parallel x 2 in series
Number of PV modules 6 units Discharging min. SOC 20.0 %
Nominal (STC) 2700 Wp Stored energy 24.0 kWh
Modules 6 Strings x 1 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 24 V
Pmpp 2450 Wp Nominal Capacity 1250 Ah (C10)
U mpp 37 V Temperature Average between fixed 25 °C
I mpp 66 A and External

Controller Battery Management control


Universal controller Threshold commands as SOC calculation
Technology Series Charging SOC = 0.90 / 0.75
Temp coeff. -5.0 mV/°C/Elem. approx. 4.4 / 4.1 V
Discharging SOC = 0.20 / 0.45
approx. 3.9 / 4.0 V

Total PV power
Nominal (STC) 2.70 kWp
Total 6 modules
Module area 13.0 m²

Array losses
Thermal Loss factor DC wiring losses Serie Diode Loss
Module temperature according to irradiance Global array res. 9.4 mΩ Voltage drop 0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 1.7 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module Quality Loss Module mismatch losses Strings Mismatch loss


Loss Fraction -0.8 % Loss Fraction 0.0 % at MPP Loss Fraction 0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel, AR coating, n(glass)=1.526, n(AR)=1.290

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000

P
08/07/23 Page 3/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 7.3 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
Luminarias Led 2x18W 18 36/lamp 8.0 5184
Tomas 120V 5 100/app 4.0 2000
Stand-by consumers 24.0 144
Total daily energy 7328

P
08/07/23 Page 4/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
with v7.4.0

System Production
Useful energy from solar 369.62 kWh/year Perf. Ratio PR 7.78 %
Available solar energy 464.07 kWh/year Solar Fraction SF 13.82 %
Excess (unused) 0.00 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 86.7 % Cycles SOW 94.4 %
Missing Energy 2305.10 kWh/year Static SOW 82.6 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

GlobHor GlobEff E_Avail EUnused E_Miss E_User E_Load SolFrac


kWh/m² kWh/m² kWh kWh kWh kWh kWh ratio
January 150.7 157.6 42.71 0.000 192.0 35.22 227.2 0.155
February 135.2 138.4 37.53 0.000 175.5 29.69 205.2 0.145
March 152.2 149.8 40.61 0.000 194.4 32.72 227.2 0.144
April 139.5 131.8 35.77 0.000 191.7 28.16 219.8 0.128
May 146.3 133.7 36.29 0.000 199.2 28.00 227.2 0.123
June 144.9 129.1 35.07 0.000 192.0 27.79 219.8 0.126
July 155.0 139.3 37.82 0.000 197.0 30.17 227.2 0.133
August 157.2 145.9 39.56 0.000 194.1 33.06 227.2 0.146
September 150.9 145.5 39.44 0.000 188.9 30.98 219.8 0.141
October 145.7 146.8 39.82 0.000 196.7 30.50 227.2 0.134
November 138.0 142.5 38.67 0.000 189.1 30.73 219.8 0.140
December 142.6 150.3 40.77 0.000 194.6 32.60 227.2 0.143
Year 1758.2 1710.8 464.07 0.000 2305.1 369.62 2674.7 0.138

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

P
08/07/23 Page 5/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
with v7.4.0

1758 kWh/m² Global horizontal irradiation


+0.0% Global incident in coll. plane

-2.71% IAM factor on global

1711 kWh/m² * 13 m² coll. Effective irradiation on collectors

efficiency at STC = 20.75% PV conversion

4621 kWh Array nominal energy (at STC effic.)


-0.82% PV loss due to irradiance level

PV loss due to temperature

+0.75% Module quality loss

-0.15% Mismatch loss, modules and strings

-2.94% Ohmic wiring loss

Missing energy 0.00% Unused energy (battery full)


86.18% 464 kWh Effective energy at the output of the array
Direct
Stored
use Battery Storage
16.6%
83.4%
-0.40% Battery Stored Energy balance
-19.89% Battery efficiency loss
-2.95% Charge/Disch. Current Efficiency Loss
0.00% Gassing Current (electrolyte dissociation)
-0.34% Battery Self-discharge Current
2305 kWh
370 kWh Energy supplied to the user

Energy need of the user (Load)

P
08/07/23 Page 6/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
with v7.4.0

PVsyst TRIAL

P
08/07/23 Page 7/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
with v7.4.0

PVsyst TRIAL

P
08/07/23 Page 8/8