Variant: New simulation variant
PVsyst V7.3.1
VC0, Simulation date:
02/10/24 15:17
with v7.3.1
Project summary
Geographical Site Situation Project settings
Sālim al Ḩammādi Latitude 33.25 °N Albedo 0.20
Iraq Longitude 44.39 °E
Altitude 34 m
Time zone UTC+3
Meteo data
Sālim al Ḩammādi
Meteonorm 8.1 (1985-2002), Sat=100% - Synthetic
System summary
Standalone system Standalone system with batteries
System information
PV Array Battery pack
Nb. of modules 14 units Technology Lithium-ion, LFP
Pnom total 8.54 kWp Nb. of units 6 units
Voltage 51 V
Capacity 1560 Ah
Results summary
Available Energy 14431 kWh/year Specific production 1690 kWh/kWp/year Perf. Ratio PR 76.68 %
Used Energy 13347 kWh/year Solar Fraction SF 92.41 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 5
Main results 6
Loss diagram 7
Predef. graphs 8
PVsyst V7.3.1
VC0, Simulation date:
02/10/24 15:17
with v7.3.1
General parameters
Standalone system Standalone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
User's needs
Daily household consumers
Constant over the year
Average 39.6 kWh/Day
PV Array Characteristics
PV module Battery
Manufacturer Jinkosolar Manufacturer BYD
Model JKM-610N-78HL4-BDV Model B-Box PRO 13.8
(Original PVsyst database) Technology Lithium-ion, LFP
Unit Nom. Power 610 Wp Nb. of units 6 in parallel
Number of PV modules 14 units Discharging min. SOC 20.0 %
Nominal (STC) 8.54 kWp Stored energy 63.9 kWh
Modules 14 Strings x 1 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 51 V
Pmpp 7.90 kWp Nominal Capacity 1560 Ah (C10)
U mpp 42 V Temperature Fixed 20 °C
I mpp 187 A
Total PV power
Nominal (STC) 9 kWp
Total 14 modules
Module area 39.1 m²
Array losses
Array Soiling Losses Thermal Loss factor DC wiring losses
Loss Fraction 3.0 % Module temperature according to irradiance Global array res. 3.7 mΩ
Uc (const) 29.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
Serie Diode Loss LID - Light Induced Degradation Module Quality Loss
Voltage drop 0.7 V Loss Fraction 2.0 % Loss Fraction -0.8 %
Loss Fraction 1.5 % at STC
PVsyst V7.3.1
VC0, Simulation date:
02/10/24 15:17
with v7.3.1
Array losses
IAM loss factor
Incidence effect (IAM): Fresnel, AR coating, n(glass)=1.526, n(AR)=1.290
PVsyst V7.3.1
VC0, Simulation date:
02/10/24 15:17
with v7.3.1
PVsyst V7.3.1
VC0, Simulation date:
02/10/24 15:17
with v7.3.1
Main results
System Production
Available Energy 14431 kWh/year Performance Ratio PR 76.68 %
Used Energy 13347 kWh/year Solar Fraction SF 92.41 %
Excess (unused) 468 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 13.9 % Cycles SOW 97.8 %
Missing Energy 1096 kWh/year Static SOW 90.0 %
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst V7.3.1
VC0, Simulation date:
02/10/24 15:17
with v7.3.1
Loss diagram
1820 kWh/m² Global horizontal irradiation
+12.0% Global incident in coll. plane
PVsyst V7.3.1
VC0, Simulation date:
02/10/24 15:17
with v7.3.1
Predef. graphs
Daily Input/Output diagram