PVsyst - Simulation report
Standalone system

Project: Simulacion diseño fotovoltaico


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 2400 Wp

PVsyst TRIAL
TECSUP AREQUIPA - Perú

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Simulacion diseño fotovoltaico
Variant: Nueva variante de simulación

PVsyst V7.3.4
VC0, Simulation date:
09/06/23 00:46

PVsyst TRIAL
with v7.3.4

Project summary
Geographical Site Situation Project settings
TECSUP AREQUIPA Latitude -16.43 °S Albedo 0.20
Perú Longitude -71.52 °W
Altitude 2363 m
Time zone UTC-5

Meteo data
TECSUP AREQUIPA
Meteonorm 8.1 (2010-2017), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 30 ° Constant over the year
Average 1.1 kWh/Day

System information
PV Array Battery pack
Nb. of modules 6 units Technology Lead-acid, sealed, Gel
Pnom total 2400 Wp Nb. of units 4 units
Voltage 48 V
Capacity 65 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 386.28 kWh/year
Missing Energy
Excess (unused)
0.00 kWh/year
5090.48 kWh/year

Project and results summary


Specific production 161 kWh/kWp/year Perf. Ratio PR
Available solar energy 5698.76 kWh/year

Table of contents
Solar Fraction SF
5.83 %
100.00 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
09/06/23 PVsyst Evaluation mode Page 2/7
Project: Simulacion diseño fotovoltaico
Variant: Nueva variante de simulación

PVsyst V7.3.4
VC0, Simulation date:
09/06/23 00:46

PVsyst TRIAL
with v7.3.4

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 30 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 1.1 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 400 Wp
PV Array Characteristics

Generic
LG 400 N2W-A5
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
MPG 12V 65 F
Lead-acid, sealed, Gel
4 in series
Number of PV modules 6 units Discharging min. SOC 10.0 %
Nominal (STC) 2400 Wp Stored energy 2.9 kWh
Modules 1 String x 6 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 2186 Wp Nominal Capacity 65 Ah (C10)
U mpp 220 V Temperature Fixed 20 °C
I mpp 9.9 A

PVsyst TRIAL
Controller
Manufacturer
Model
Technology
Temp coeff.
Converter
MPPT converter
Generic
Flatpack2 48/3200 HE Solar

-4.0 mV/°C/Elem.
Battery Management control
Threshold commands as
Charging
Corresp. SOC
Discharging
Corresp. SOC
Battery voltage
63.0 / 51.5 V
0.96 / 0.82
42.9 / 49.2 V
0.01 / 0.37
Maxi and EURO efficiencies 97.0 / 95.5 %

Total PV power
Nominal (STC) 2.40 kWp
Total 6 modules
Module area 12.4 m²
Cell area 11.2 m²

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


20.0 W/m²K
0.0 W/m²K/m/s
DC wiring losses

Loss Fraction
Array losses

Global array res.

Module mismatch losses


364 mΩ
1.5 % at STC
Serie Diode Loss
Voltage drop
Loss Fraction
0.7 V
0.3 % at STC

Loss Fraction -0.8 % Loss Fraction 2.0 % at MPP

IAM loss factor


Incidence effect (IAM): Fresnel, AR coating, n(glass)=1.526, n(AR)=1.290

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000

PVsyst TRIAL
09/06/23 PVsyst Evaluation mode Page 3/7
Project: Simulacion diseño fotovoltaico
Variant: Nueva variante de simulación

PVsyst V7.3.4
VC0, Simulation date:
09/06/23 00:46

PVsyst TRIAL
with v7.3.4

Detailed User's needs


Daily household consumers, Constant over the year, average = 1.1 kWh/day
Annual values Hourly distribution

Use 5 days a week Nb. Power Use Energy


W Hour/day Wh/day
Lámparas (LED o fluo) 1 20/lamp 4.0 80
Otros usos 1 100 tot 14.0 1400
Total daily energy 1480

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
09/06/23 PVsyst Evaluation mode Page 4/7
Project: Simulacion diseño fotovoltaico
Variant: Nueva variante de simulación

PVsyst V7.3.4
VC0, Simulation date:
09/06/23 00:46

PVsyst TRIAL
with v7.3.4

Main results
System Production
Useful energy from solar 386.28 kWh/year Perf. Ratio PR 5.83 %
Available solar energy 5698.76 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 5090.48 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 85.7 %
Missing Energy 0.00 kWh/year Static SOW 91.7 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
232.0
197.6
229.3
210.4
GlobEff
kWh/m²
210.4
187.3
230.5
225.4
E_Avail
kWh
450.1
401.3
486.5
474.1
EUnused
kWh
393.0
357.1
431.0
422.0
E_Miss
kWh
0.000
0.000
0.000
0.000
E_User
kWh
34.04
29.60
32.56
31.08
E_Load
kWh
34.04
29.60
32.56
31.08
SolFrac
ratio
1.000
1.000
1.000
1.000
May 198.8 227.3 478.2 423.2 0.000 34.04 34.04 1.000
June 182.2 213.7 453.0 403.6 0.000 31.08 31.08 1.000
July 194.4 224.5 475.3 430.1 0.000 32.56 32.56 1.000
August 199.7 219.5 463.0 409.0 0.000 34.04 34.04 1.000
September 219.5 225.7 474.1 426.3 0.000 29.60 29.60 1.000
October 255.3 247.8 517.1 467.8 0.000 34.04 34.04 1.000
November 263.9 244.9 510.9 459.4 0.000 32.56 32.56 1.000

PVsyst TRIAL
December 272.5 245.5 515.2 467.9 0.000 31.08 31.08 1.000
Year 2655.7 2702.6 5698.8 5090.5 0.000 386.28 386.28 1.000

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
09/06/23 PVsyst Evaluation mode Page 5/7
Project: Simulacion diseño fotovoltaico
Variant: Nueva variante de simulación

PVsyst V7.3.4
VC0, Simulation date:
09/06/23 00:46

PVsyst TRIAL
with v7.3.4

Loss diagram
2656 kWh/m² Global horizontal irradiation
+3.9% Global incident in coll. plane

-2.03% IAM factor on global

2703 kWh/m² * 12 m² coll. Effective irradiation on collectors

efficiency at STC = 19.33% PV conversion

6495 kWh Array nominal energy (at STC effic.)

PVsyst TRIAL
+0.07% PV loss due to irradiance level

-9.03% PV loss due to temperature

+0.75% Module quality loss

-2.00% Module array mismatch loss

-1.69% Ohmic wiring loss

PVsyst TRIAL
-88.70% Unused energy (battery full)

648 kWh Effective energy at the output of the array

-5.84% Converter Loss during operation (efficiency)


-0.36% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold

PVsyst TRIAL
608 kWh Converter losses (effic, overload)
Direct
Stored
use Battery Storage
Missing13.2%
86.8%
+0.11% Battery Stored Energy balance
energy
0.00%
-21.51% Battery efficiency loss
0.0 kWh
-2.42% Charge/Disch. Current Efficiency Loss
-9.94% Gassing Current (electrolyte dissociation)
-0.23% Battery Self-discharge Current
386 kWh Energy supplied to the user
386 kWh Energy need of the user (Load)

PVsyst TRIAL
09/06/23 PVsyst Evaluation mode Page 6/7
Project: Simulacion diseño fotovoltaico
Variant: Nueva variante de simulación

PVsyst V7.3.4
VC0, Simulation date:
09/06/23 00:46

PVsyst TRIAL
with v7.3.4

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
09/06/23 PVsyst Evaluation mode Page 7/7