Professional Documents
Culture Documents
21
PVsyst TRIAL
PVsyst - Simulation report
Grid-Connected System
PVsyst TRIAL
Alvares 589, isla de maipo - Chile
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: Casa Parcela
Variant: Nueva variante de simulación
PVsyst V7.2.21
VC0, Simulation date:
28/11/22 15:15
PVsyst TRIAL
with v7.2.21
Project summary
Geographical Site Situation Project settings
Alvares 589, isla de maipo Latitude -33.76 °S Albedo 0.20
Chile Longitude -70.91 °W
Altitude 319 m
Time zone UTC-4
Meteo data
Alvares 589, isla de maipo
Meteonorm 8.0 (1996-2015), Sat=8% - Sintético
System summary
PVsyst TRIAL
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters
Nb. of modules 54 units Nb. of units 0.5 unit
Pnom total 29.43 kWp Pnom total 20.00 kWac
Pnom ratio 1.472
Results summary
Produced Energy 42.13 MWh/year Specific production 1431 kWh/kWp/year Perf. Ratio PR 79.38 %
PVsyst TRIAL
Project and results summary
Main results
Loss diagram
Special graphs
Table of contents
PVsyst TRIAL
PVsyst TRIAL
28/11/22 PVsyst Evaluation mode Page 2/6
Project: Casa Parcela
Variant: Nueva variante de simulación
PVsyst V7.2.21
VC0, Simulation date:
28/11/22 15:15
PVsyst TRIAL
with v7.2.21
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 25 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
PVsyst TRIAL
PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model JKM-545M-72HL4-TV Model SUN2000-40KTL-M3-380V
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 545 Wp Unit Nom. Power 40.0 kWac
Number of PV modules 54 units Number of inverters 2 * MPPT 25% 0.5 unit
Nominal (STC) 29.43 kWp Total power 20.0 kWac
Modules 3 Strings x 18 In series Operating voltage 200-1000 V
At operating cond. (50°C) Max. power (=>40°C) 44.0 kWac
Pmpp 26.85 kWp Pnom ratio (DC:AC) 1.47
U mpp 674 V
I mpp 40 A
PVsyst TRIAL
Total PV power Total inverter power
Nominal (STC) 29 kWp Total power 20 kWac
Total 54 modules Nb. of inverters 1 unit
Module area 139 m² 0.5 unused
Pnom ratio 1.47
Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 280 mΩ Loss Fraction -0.8 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst TRIAL
IAM loss factor
Incidence effect (IAM): Fresnel, AR coating, n(glass)=1.526, n(AR)=1.290
PVsyst TRIAL
28/11/22 PVsyst Evaluation mode Page 3/6
Project: Casa Parcela
Variant: Nueva variante de simulación
PVsyst V7.2.21
VC0, Simulation date:
28/11/22 15:15
PVsyst TRIAL
with v7.2.21
Main results
System Production
Produced Energy 42.13 MWh/year Specific production 1431 kWh/kWp/year
Performance Ratio PR 79.38 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
February 180.0 67.39 21.75 186.2 181.8 4.219 4.131 0.754
March 161.0 63.61 19.75 181.7 177.6 4.229 4.141 0.774
April 105.1 47.65 15.03 132.6 130.0 3.304 3.234 0.829
May 69.9 35.45 11.44 92.6 90.8 2.388 2.337 0.858
June 52.8 30.83 8.30 71.5 70.0 1.921 1.880 0.893
July 63.8 35.83 7.91 86.3 84.5 2.317 2.267 0.893
August 84.4 45.84 9.86 104.8 102.6 2.709 2.651 0.859
September 120.3 60.03 12.24 138.6 135.7 3.459 3.386 0.830
October 164.5 68.36 15.35 175.0 171.2 4.100 4.012 0.779
November 203.6 78.47 18.39 199.2 194.2 4.585 4.487 0.766
December 231.7 80.82 21.19 217.0 211.4 4.884 4.781 0.749
Year 1665.0 699.44 15.30 1803.2 1762.1 43.037 42.127 0.794
PVsyst TRIAL
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst TRIAL
28/11/22 PVsyst Evaluation mode Page 4/6
Project: Casa Parcela
Variant: Nueva variante de simulación
PVsyst V7.2.21
VC0, Simulation date:
28/11/22 15:15
PVsyst TRIAL
with v7.2.21
Loss diagram
1665 kWh/m² Global horizontal irradiation
+8.3% Global incident in coll. plane
+0.75%
-2.10%
-1.07%
PV loss due to temperature
PVsyst TRIAL
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
-0.03% Night consumption
42.13 MWh Available Energy at Inverter Output
42.13 MWh Energy injected into grid
PVsyst TRIAL
PVsyst TRIAL
28/11/22 PVsyst Evaluation mode Page 5/6
Project: Casa Parcela
Variant: Nueva variante de simulación
PVsyst V7.2.21
VC0, Simulation date:
28/11/22 15:15
PVsyst TRIAL
with v7.2.21
Special graphs
Diagrama entrada/salida diaria
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
28/11/22 PVsyst Evaluation mode Page 6/6