You are on page 1of 7

Version 7.3.

PVsyst TRIAL
PVsyst - Simulation report
Grid-Connected System

Project: ses
Variant: Nouvelle variante de simulation
No 3D scene defined, no shadings
System power: 35.6 kWp

PVsyst TRIAL Oujda-Angad - Morocco

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: ses
Variant: Nouvelle variante de simulation

PVsyst V7.3.4
VC0, Simulation date:
23/06/23 21:23

PVsyst TRIAL
with v7.3.4

Project summary
Geographical Site Situation Project settings
Oujda-Angad Latitude 34.68 °N Albedo 0.20
Morocco Longitude -1.91 °W
Altitude 562 m
Time zone UTC

Meteo data
Oujda-Angad
PVGIS api TMY

System summary

PVsyst TRIAL
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Unlimited load (grid)
Tilt/Azimuth 30 / 0 °

System information
PV Array Inverters
Nb. of modules 54 units Nb. of units 1 unit
Pnom total 35.6 kWp Pnom total 33.3 kWac
Pnom ratio 1.070

Results summary
Produced Energy 68357 kWh/year Specific production 1918 kWh/kWp/year Perf. Ratio PR 86.82 %

PVsyst TRIAL
Project and results summary

Main results
Loss diagram
Predef. graphs
Table of contents

General parameters, PV Array Characteristics, System losses


2
3
4
5
6
Single-line diagram 7

PVsyst TRIAL

PVsyst TRIAL
23/06/23 PVsyst Evaluation mode Page 2/7
Project: ses
Variant: Nouvelle variante de simulation

PVsyst V7.3.4
VC0, Simulation date:
23/06/23 21:23

PVsyst TRIAL
with v7.3.4

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Imported
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Unlimited load (grid)

PVsyst TRIAL
PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model AE 660ME-132 Model SE33.3K-EU-APAC (480V)
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 660 Wp Unit Nom. Power 33.3 kWac
Number of PV modules 54 units Number of inverters 1 unit
Nominal (STC) 35.6 kWp Total power 33.3 kWac
Optimizer Array 2 Strings x 27 In series Operating voltage 840 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.08
Pmpp 32.6 kWp
Output of optimizers
Voper 840 V
I at Poper 39 A

PVsyst TRIAL
SolarEdge Power Optimizer
Model
Unit Nom. Power
Input modules

Total PV power
Nominal (STC)
P750 Worldwide
750 W
One module

36 kWp
Total inverter power
Total power 33.3 kWac
Total 54 modules Number of inverters 1 unit
Module area 168 m² Pnom ratio 1.07
Cell area 157 m²

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 297 mΩ Loss Fraction -0.8 %

PVsyst TRIAL
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses


Loss Fraction 0.0 % at MPP

IAM loss factor


Incidence effect (IAM): Fresnel, AR coating, n(glass)=1.526, n(AR)=1.290

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000

PVsyst TRIAL
23/06/23 PVsyst Evaluation mode Page 3/7
Project: ses
Variant: Nouvelle variante de simulation

PVsyst V7.3.4
VC0, Simulation date:
23/06/23 21:23

PVsyst TRIAL
with v7.3.4

Main results
System Production
Produced Energy 68357 kWh/year Specific production 1918 kWh/kWp/year
Perf. Ratio PR 86.82 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² kWh kWh ratio
January 97.0 30.65 8.16 153.9 151.7 5077 4996 0.911

PVsyst TRIAL
February 113.8 36.33 7.38 158.8 156.3 5144 5061 0.894
March 145.8 53.83 11.31 174.0 170.8 5501 5411 0.873
April 186.5 58.96 16.39 198.0 194.4 6128 6027 0.854
May 215.0 71.05 15.57 207.3 202.9 6501 6395 0.865
June 224.0 69.03 23.14 206.7 201.9 6345 6242 0.847
July 223.8 72.71 27.43 213.1 208.8 6461 6356 0.837
August 219.4 62.35 26.32 225.5 221.3 6836 6725 0.837
September 156.8 57.73 19.46 179.3 176.1 5616 5524 0.864
October 147.1 43.10 19.84 196.8 193.8 6151 6051 0.863
November 108.0 33.40 14.46 166.6 164.1 5383 5297 0.892
December 80.1 30.46 6.62 129.1 127.1 4342 4272 0.928
Year 1917.2 619.60 16.39 2209.2 2169.2 69486 68357 0.868

PVsyst TRIAL
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

PVsyst TRIAL
23/06/23 PVsyst Evaluation mode Page 4/7
Project: ses
Variant: Nouvelle variante de simulation

PVsyst V7.3.4
VC0, Simulation date:
23/06/23 21:23

PVsyst TRIAL
with v7.3.4

Loss diagram
1917 kWh/m² Global horizontal irradiation
+15.2% Global incident in coll. plane

-1.81% IAM factor on global

2169 kWh/m² * 168 m² coll. Effective irradiation on collectors

efficiency at STC = 21.25% PV conversion

77309 kWh Array nominal energy (at STC effic.)

PVsyst TRIAL
-0.59% PV loss due to irradiance level

-8.18% PV loss due to temperature

-0.56% Optimizer efficiency loss


-0.76% Optimizer current overload loss
+0.75% Module quality loss

0.00% Module array mismatch loss


-0.96% Ohmic wiring loss
69486 kWh Array virtual energy at MPP
-1.62% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power

PVsyst TRIAL
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
68357 kWh Available Energy at Inverter Output
68357 kWh Energy injected into grid

PVsyst TRIAL

PVsyst TRIAL
23/06/23 PVsyst Evaluation mode Page 5/7
Project: ses
Variant: Nouvelle variante de simulation

PVsyst V7.3.4
VC0, Simulation date:
23/06/23 21:23

PVsyst TRIAL
with v7.3.4

Predef. graphs
Diagramme d'entrée/sortie journalier

PVsyst TRIAL

PVsyst TRIAL Distribution de la puissance de sortie système

PVsyst TRIAL

PVsyst TRIAL
23/06/23 PVsyst Evaluation mode Page 6/7
PVsyst V7.3.4
VC0, Simulation date:
23/06/23 21:23
with v7.3.4

You might also like