You are on page 1of 7

Version 7.3.

PVsyst TRIAL
PVsyst - Simulation report
Grid-Connected System

Project: first project


Variant: New simulation variant
No 3D scene defined, no shadings
System power: 149 kWp

PVsyst TRIAL
Budapest/Vecsés - Hungary

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: first project
Variant: New simulation variant

PVsyst V7.3.4
VC0, Simulation date:
05/11/23 09:30

PVsyst TRIAL
with v7.3.4

Project summary
Geographical Site Situation Project settings
Budapest/Vecsés Latitude 47.44 °N Albedo 0.20
Hungary Longitude 19.26 °E
Altitude 185 m
Time zone UTC+1

Meteo data
Budapest/Vecsés
Meteonorm 8.1 (1991-2006) - Synthetic

System summary

PVsyst TRIAL
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Unlimited load (grid)
Tilt/Azimuth 10 / -41 °

System information
PV Array Inverters
Nb. of modules 324 units Nb. of units 1 unit
Pnom total 149 kWp Pnom total 100 kWac
Pnom ratio 1.490

Results summary
Produced Energy 168249 kWh/year Specific production 1129 kWh/kWp/year Perf. Ratio PR 86.76 %

PVsyst TRIAL
Project and results summary
General parameters, PV Array Characteristics, System losses
Main results
Loss diagram
Predef. graphs
Table of contents
2
3
4
5
6
Single-line diagram 7

PVsyst TRIAL

PVsyst TRIAL
05/11/23 PVsyst Evaluation mode Page 2/7
Project: first project
Variant: New simulation variant

PVsyst V7.3.4
VC0, Simulation date:
05/11/23 09:30

PVsyst TRIAL
with v7.3.4

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 10 / -41 ° Diffuse Perez, Meteonorm
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Unlimited load (grid)

PVsyst TRIAL
PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model JAM72-S20-460-MR Model SP-100K-L
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 460 Wp Unit Nom. Power 100 kWac
Number of PV modules 324 units Number of inverters 9 * MPPT 11% 1 unit
Nominal (STC) 149 kWp Total power 100 kWac
Modules 18 Strings x 18 In series Operating voltage 200-1000 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.49
Pmpp 137 kWp No power sharing between MPPTs
U mpp 693 V
I mpp 197 A

PVsyst TRIAL
Total PV power Total inverter power
Nominal (STC) 149 kWp Total power 100 kWac
Total 324 modules Number of inverters 1 unit
Module area 720 m² Pnom ratio 1.49

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 58 mΩ Loss Fraction -0.8 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses Strings Mismatch loss


Loss Fraction 2.0 % at MPP Loss Fraction 0.2 %

IAM loss factor

PVsyst TRIAL
Incidence effect (IAM): User defined profile

0° 30° 50° 65° 70° 75° 80° 85° 90°


1.000 1.000 0.992 0.943 0.898 0.813 0.677 0.426 0.000

PVsyst TRIAL
05/11/23 PVsyst Evaluation mode Page 3/7
Project: first project
Variant: New simulation variant

PVsyst V7.3.4
VC0, Simulation date:
05/11/23 09:30

PVsyst TRIAL
with v7.3.4

Main results
System Production
Produced Energy 168249 kWh/year Specific production 1129 kWh/kWp/year
Perf. Ratio PR 86.76 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² kWh kWh ratio
January 30.8 17.86 -0.55 36.4 34.3 5038 4955 0.913

PVsyst TRIAL
February 56.0 24.17 0.94 64.4 61.6 9018 8899 0.927
March 92.0 50.45 5.91 98.9 95.7 13678 13510 0.916
April 129.4 66.86 11.61 134.9 131.3 17796 17587 0.875
May 171.6 71.95 16.62 176.4 172.1 22577 22319 0.849
June 180.7 72.91 20.12 184.1 179.9 23217 22957 0.837
July 180.7 84.52 22.43 184.5 180.3 23321 23055 0.838
August 155.0 75.43 21.98 161.0 156.9 20795 20558 0.856
September 106.3 53.24 16.13 113.4 110.0 14994 14813 0.876
October 71.2 37.43 10.94 78.2 75.0 10564 10426 0.895
November 34.2 19.67 5.74 39.3 36.9 5314 5227 0.892
December 24.8 15.29 0.39 29.4 27.5 4018 3942 0.899
Year 1232.9 589.78 11.08 1301.1 1261.5 170331 168249 0.868

PVsyst TRIAL
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

PVsyst TRIAL
05/11/23 PVsyst Evaluation mode Page 4/7
Project: first project
Variant: New simulation variant

PVsyst V7.3.4
VC0, Simulation date:
05/11/23 09:30

PVsyst TRIAL
with v7.3.4

Loss diagram
1233 kWh/m² Global horizontal irradiation
+5.5% Global incident in coll. plane

-3.04% IAM factor on global

1262 kWh/m² * 720 m² coll. Effective irradiation on collectors

efficiency at STC = 20.71% PV conversion

188051 kWh Array nominal energy (at STC effic.)

PVsyst TRIAL
-1.84% PV loss due to irradiance level

-4.05% PV loss due to temperature

+0.75% Module quality loss

-2.15% Mismatch loss, modules and strings

-0.81% Ohmic wiring loss


173194 kWh Array virtual energy at MPP
-1.19% Inverter Loss during operation (efficiency)

-1.67% Inverter Loss over nominal inv. power


0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage

PVsyst TRIAL
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
-0.01% Night consumption
168249 kWh Available Energy at Inverter Output
168249 kWh Energy injected into grid

PVsyst TRIAL

PVsyst TRIAL
05/11/23 PVsyst Evaluation mode Page 5/7
Project: first project
Variant: New simulation variant

PVsyst V7.3.4
VC0, Simulation date:
05/11/23 09:30

PVsyst TRIAL
with v7.3.4

Predef. graphs
Daily Input/Output diagram

PVsyst TRIAL

PVsyst TRIAL System Output Power Distribution

PVsyst TRIAL

PVsyst TRIAL
05/11/23 PVsyst Evaluation mode Page 6/7
PVsyst V7.3.4
VC0, Simulation date:
05/11/23 09:30
with v7.3.4

You might also like