You are on page 1of 6

MEXICO AREA 1 DEVELOPMENT

Amoca WHP2 & Tecoalli EPC

Tecoalli
Deck

Technical Data Sheet (TDS) for Choke Valves

EX-DE 00 20/12/2022 Issue for Comments M. Pupo F. Sarcina M. Diaz T. Flores F. Presta
Validity Revision
Contractor Contractor Contractor Company Company
Status Number Date Description
Prepared Checked Approved Checked Approved
Revision index
Company logo and business name LCI Activity Code Company Document ID:
LCI-MX-2022-0002
6008T2DIGA27014
Project Code
000481 Job N.:
Contractor logo and business name Contractor Document ID:
TC-001CM07TDS27014
Construcciones Mecanicas Monclova, SA de CV
Contract N.:
Vendor logo and business name Vendor Document ID

Purchase Order N.:


Facility and Sub Facility Description Project and SoW Description Scale Sheet of Sheets

MEXICO AREA 1 DEVELOPMENT –


TECOALLI - Deck n.a. 1/6
Amoca WP2 & Tecoalli EPC
Document Title Supersedes N.

Superseded by N.
Technical Data Sheet (TDS) for Choke Valves Plant area Functional unit
n.a. n.a.
Software: Microsoft Excel File Name: 6008T2DIGA27014_EXDE00_06
This document is property of Eni S.p.A.
It shall neither be shown to Third Parties nor used for purposes other than those for which it has been sent.
Company Logo Contractor Logo Vendor Logo Validity Revision
Status Number

EX-DE 00

Company Document ID Contractor Document ID Vendor Document ID


Sheet of Sheets
2/6
6008T2DIGA27014 TC-001CM07TDS27014

REVISION LIST
EX-DE 00 Issue for Comments

HOLD RECORD

REFERENCES

28045.ENG.STA.PRG Design Guidelines for Instrumentation and Control Systems


29000.ENG.CPI.STD Painting for offshore and coastal structures
6008T2DISG19005 General Specification for Instrumentation
6008T2DIGB19046 Inspection Data Sheet (IDS) for Choke Valves
6008T2DIGC19055 Requested Document Data Sheet (Rdds) For Choke Valves
6008T2DXST18504 Coating Specification for Tecoalli Topside & Jacket

GENERAL NOTES
1)The actuator motorized must have the following local commands: Local / Remote selector, Stop, Opening & Closing of the
valve; Valve position (4-20mA HART SMART) and valve commands are Hardwired to DCS; In addition, redundant MODBUS
TCP/IP interface SHALL be provided.
2) Actuator, electric supply: 480VAC / 3 PH / 60 Hz, Degree of protection IP65 min..
3) Process data at the inlet of choke valve in nameplate case.
4) Density and viscosity of process data is for the liquid phase in nameplate case.
5) Valve shall be Fire safe ISO 10497.
6) Painting shall be according to Company Standard 29000.ENG.CPI.STD Painting for offshore and coastal structures and
project specification 6008T2DXST18504, Coating Specification for Tecoalli Topside & Jacket

Table 1
Proprierties at different pressure and temperature at inlet of choke valve
Pressure (barg) 24 25 44 164
T21000HCV 1001 Biphase : % wt Vapour 6,95 6,85 5,1 -
61°C Density @Oper. Cond. 821,4 820,5 802,1 741,6
Gas Molecular Weight 18,09 18,04 17,56 -
Spec Heat Ratio(Cp/Cv) 1,32 1,32 1,38 1,21
T21000HCV 2001 Biphase : % wt Vapour 7,2 7,1 5,4 -
67°C Density @Oper. Cond. 817,7 816,8 798,8 734,5
Gas Molecular Weight 18,31 18,26 17,72 -
Spec Heat Ratio(Cp/Cv) 1,31 1,32 1,37 -
T21000HCV 3001 Biphase : % wt Vapour 7,23 7,14 5,4 -
68°C Density @Oper. Cond. 817,1 816,2 798,3 733,3
Gas Molecular Weight 18,34 18,3 17,75 -
Spec Heat Ratio(Cp/Cv) 1,31 1,31 1,37 -

This document is property of Eni S.p.A.


It shall neither be shown to Third Parties nor used for purposes other than those for which it has been sent.
Company Logo Contractor Logo Vendor Logo Validity Revision
Status Number
EX-DE 00
Company Document ID Contractor Document ID Vendor Document ID
Sheet of Sheets
3/6
6008T2DIGA27009 TC-001CM07TDS27009

INDEX
1 COVER
2 REV LIST-HOLD RECORD
3 INDEX
4 T21000HCV 1001
5 T21000HCV 2001
6 T21000HCV 3001 (future)

This document is property of Eni S.p.A.


It shall neither be shown to Third Parties nor used for purposes other than those for which it has been sent.
Company Logo Contractor Logo Vendor Logo Validity Revision
Status Number

EX-DE 00

Company Document Id Contractor Document Id Vendor Document ID


Sheet of Sheets

4/6
6008T2DIGA27014 TC-001CM07TDS27014

CHOKE VALVES AND REGULATORS


1 Tag Number P&ID Number T21000HCV 1001 6008T2DPFM31533 sh.01
2 Service Run Nr. WellHead DW101 Choke Valve 1
3 Area Classif. Environment Temp. °C CLASS I, ZONE 1 IIB T3 Min. 14 Max. 39
GENERAL 4 INLET OUTLET INLET OUTLET
5 Line Number Line Size T21000WF1001-6"-22F-P T21000WF1002-6"-22F-P 6'' 6''
6 Piping Class Line Thickness mm 22F 22F 19.05 19.05
7
8 Process Data
9 Fluid Description Fluid State Wellfluid (low temperature) Mix
10 Operating Temp. Design Temp. °C 61 110
11 Biphase : % wt Vapour Design Pressure bar-g 5.1 (See Table 1) 347
12 Vapor Press.@Oper. Cond.Critical Press. bar-a 98 287,7
13 Density @Oper. Cond. kg/m³ Viscosity cP 802.1 (See Table 1) 2,96
14 Gas Molecular Weight Gas Compress. Factor 17.56 (See Table 1) 0,93
PROCESS
15 Spec Heat Ratio(Cp/Cv) On-Off Service 1.4 (See Table 1) NO
DATA
16 Fluid Additional properties CORROSIVE, EROSIVE
17 Special Service Components CO2
18 Data Related to Flow: MIN. NORM. MAX MAX UNCONTOLLED

19 Flow kg/h 4573 45726 63771 63771


20 Inlet Pressure bar-g 24 25 44 164
21 Outlet Pressure bar-g 22 23 42 42
22 MDMT °C -46
23 Calculation Output & Selection: MIN. NORM. MAX MAX UNCONTOLLED

24 Calculated CV 8,848 (note 1) 58 (note 1) 75 (note 1) 4 (note 1)


25 Valve Opening % 18 65 85 10
26 Flow Condition VTA VTA VTA VTA

CALCULATED 27 Velocity m/s VTA VTA VTA VTA


DATA 28 Mach Number VTA VTA VTA VTA
29 Estimated Total Noise dBA @ 1mt VTA VTA VTA VTA
30 Oversize Factor Oversize CV VTA VTA
31 Selected CV Rangeability 114 (VTA) VTA
32
33 Valve Type Body Size Body Material Angle 3" ASTM A182 F51
BODY

34 Inlet Connections Rating / Facing / Finishing 3" FLANGED RJ 2500 lb ASME B16.34 / FLANGED / RJ
35 Outlet Connect. Port Size Bonnet 3" FLANGED RJ 3" One Piece- ASTM A995 GR.1B
36 Packing Lubricator NACE Requirem. VTA VTA No
37 Plug Characteristic Leakage Class Cage type or VTA Equal % ANSI/FCI 70.2 Class IV
TRIM

38 Seat Material Plug Material Stem Material DUPLEX DUPLEX DUPLEX

VALVE 39 Cage Material DUPLEX


(SEE gen. 40 Type Size Max Shut-Off DP ELECTRIC (See Note 2) VTA 347 barg
ACTUAT.

note 1,2) 41 Flow Action To On Power Failure Signal Actuator CLOSE FL barg N/A
42 Positioner Type Input Signal Air Supply Press. N/A 4-20mA barg
43 Ex Execution Electrical Conn. Ex Certificate Ex-d NPT threaded NEC 505 (or IECEx)
44 Handwheel Jacket Limit Switches Required N/A T21000ZSH/ZSL 1001
ACCESSOR.

45 Solenoid Valve Position Transm. Filter Regulator N/A T21000ZT 1001 N/A
46 Air Volume Tank LOCK-UP Others N/A N/A Travel Indicator
47 Comm. Interface MODBUS TCP/IP (redundant)
48 Manufacturer Supplier TBD TBD
MANAGEMENT
DATA
49 Valve Model Actuator Model VTA VTA
50 Purchase Order Number Quantity TBD 1
Note: 1) Valve sizing calculations is preliminary and shall be determined by the Manufacturer.
2) Electrical actuator shall be equipped with position and torque sensing equipment, motor protection, logic control and digital comm. capability.
3) All materials and components shall be guaranteed for a Design temperature of 120° C.
4) Studs - A193 B8M Cl.2 & Nuts - A194 8M shall be zinc coated (hot-dip) to ASTM A-153.
Legend: TBD-To be Defined; VTA-Vendor to Advise/Confirm.

This document is property of Eni S.p.A.It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent.
Company Logo Contractor Logo Vendor Logo Validity Revision
Status Number

EX-DE 00

Company Document Id Contractor Document Id Vendor Document ID


Sheet of Sheets

5/6
6008T2DIGA27014 TC-001CM07TDS27014

CHOKE VALVES AND REGULATORS


1 Tag Number P&ID Number T21000HCV 2001 6008T2DPFM31533 sh.02
2 Service Run Nr. WellHead DW201 Choke Valve 1
3 Area Classif. Environment Temp. °C CLASS I, ZONE 1 IIB T3 Min. 14 Max. 39
GENERAL 4 INLET OUTLET INLET OUTLET
5 Line Number Line Size T21000WF2001-6"-22F-P T21000WF2002-6"-22F-P 6" 6''
6 Piping Class Line Thickness mm 22F 22F 19.05 19.05
7
8 Process Data
9 Fluid Description Fluid State Wellfluid (low temperature) Mix
10 Operating Temp. Design Temp. °C 67 110
11 Biphase : % wt Vapour Design Pressure bar-g 5.4 (See Table 1) 347
12 Vapor Press.@Oper. Cond.Critical Press. bar-a 102 280
13 Density @Oper. Cond. kg/m³ Viscosity cP 798.8 (See Table 1) 2,75
14 Gas Molecular Weight Gas Compress. Factor 17.72 (See Table 1) 0,93
PROCESS
15 Spec Heat Ratio(Cp/Cv) On-Off Service 1.4 (See Table 1) NO
DATA
16 Fluid Additional properties CORROSIVE, EROSIVE
17 Special Service Components CO2
18 Data Related to Flow: MIN. NORM. MAX MAX UNCONTOLLED

19 Flow kg/h 1124 11238 63771 63771


20 Inlet Pressure bar-g 24 25 44 164
21 Outlet Pressure bar-g 22 23 42 42
22 MDMT °C -46
23 Calculation Output & Selection: MIN. NORM. MAX MAX UNCONTOLLED

24 Calculated CV 2,243 (note 1) 56,553 (note 1) 85,831 (note 1) 1,072 (note 1)


25 Valve Opening % 5 62 82 3
26 Flow Condition VTA VTA VTA VTA

CALCULATED 27 Velocity m/s VTA VTA VTA VTA


DATA 28 Mach Number VTA VTA VTA VTA
29 Estimated Total Noise dBA @ 1mt VTA VTA VTA VTA
30 Oversize Factor Oversize CV VTA VTA
31 Selected CV Rangeability 114 (VTA) VTA
32
33 Valve Type Body Size Body Material Angle 3" ASTM A182 F51
BODY

34 Inlet Connections Rating / Facing / Finishing 3" FLANGED RJ 2500 lb ASME B16.34 / FLANGED / RJ
35 Outlet Connect. Port Size Bonnet 3" FLANGED RJ 3" One Piece- ASTM A995 GR.1B
36 Packing Lubricator NACE Requirem. VTA VTA No
37 Plug Characteristic Leakage Class Cage type or VTA Equal % ANSI/FCI 70.2 Class IV
TRIM

38 Seat Material Plug Material Stem Material DUPLEX DUPLEX DUPLEX

VALVE 39 Cage Material DUPLEX


(SEE gen. 40 Type Size Max Shut-Off DP ELECTRIC (See Note 2) VTA 347 barg
ACTUAT.

note 1,2) 41 Flow Action To On Power Failure Signal Actuator CLOSE FL barg N/A
42 Positioner Type Input Signal Air Supply Press. N/A 4-20mA barg
43 Ex Execution Electrical Conn. Ex Certificate Ex-d NPT threaded NEC 505 (or IECEx)
44 Handwheel Jacket Limit Switches Required N/A T21000ZSH/ZSL 2001
ACCESSOR.

45 Solenoid Valve Position Transm. Filter Regulator N/A T21000ZT 2001 N/A
46 Air Volume Tank LOCK-UP Others N/A N/A Travel Indicator
47 Comm. Interface MODBUS TCP/IP (redundant)
48 Manufacturer Supplier TBD TBD
MANAGEMENT
DATA
49 Valve Model Actuator Model VTA VTA
50 Purchase Order Number Quantity TBD 1
Note: 1) Valve sizing calculations is preliminary and shall be determined by the Manufacturer.
2) Electrical actuator shall be equipped with position and torque sensing equipment, motor protection, logic control and digital comm. capability.
3) All materials and components shall be guaranteed for a Design temperature of 120° C.
4) Studs - A193 B8M Cl.2 & Nuts - A194 8M shall be zinc coated (hot-dip) to ASTM A-153.
Legend: TBD-To be Defined; VTA-Vendor to Advise/Confirm.

This document is property of Eni S.p.A.It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent.
Company Logo Contractor Logo Vendor Logo Validity Revision
Status Number

EX-DE 00

Company Document Id Contractor Document Id Vendor Document ID


Sheet of Sheets

6/6
6008T2DIGA27014 TC-001CM07TDS27014

CHOKE VALVES AND REGULATORS (future)


1 Tag Number P&ID Number T21000HCV 3001 (Future) 6008T2DPFM31533 sh.03
2 Service Run Nr. WellHead DW301 Choke Valve 1
3 Area Classif. Environment Temp. °C CLASS I, ZONE 1 IIB T3 Min. 14 Max. 39
GENERAL 4 INLET OUTLET INLET OUTLET
5 Line Number Line Size T21000WF3001-6"-22F-P T21000WF3002-6"-22F-P 6" 6''
6 Piping Class Line Thickness mm 22F 22F 19.05 19.05
7
8 Process Data
9 Fluid Description Fluid State Wellfluid (low temperature) Mix
10 Operating Temp. Design Temp. °C 68 110
11 Biphase : % wt Vapour Design Pressure bar-g 5.4 (See Table 1) 347
12 Vapor Press.@Oper. Cond.Critical Press. bar-a 103 287,3
13 Density @Oper. Cond. kg/m³ Viscosity cP 798.3 (See Table 1) 2,7
14 Gas Molecular Weight Gas Compress. Factor 17.75 (See Table 1) 0,93
PROCESS
15 Spec Heat Ratio(Cp/Cv) On-Off Service 1.4 (See Table 1) NO
DATA
16 Fluid Additional properties CORROSIVE, EROSIVE
17 Special Service Components CO2
18 Data Related to Flow: MIN. NORM. MAX MAX UNCONTOLLED

19 Flow kg/h 4572,6 45726 63771 63771


20 Inlet Pressure bar-g 24 25 44 164
21 Outlet Pressure bar-g 22 23 42 42
22 MDMT °C -46
23 Calculation Output & Selection: MIN. NORM. MAX MAX UNCONTOLLED

24 Calculated CV 9,139 (note 1) 89,074 (note 1) 85,14 (note 1) 1,072 (note 1)


25 Valve Opening % 16 63 60 3
26 Flow Condition VTA VTA VTA VTA

CALCULATED 27 Velocity m/s VTA VTA VTA VTA


DATA 28 Mach Number VTA VTA VTA VTA
29 Estimated Total Noise dBA @ 1mt VTA VTA VTA VTA
30 Oversize Factor Oversize CV VTA VTA
31 Selected CV Rangeability 114 (VTA) VTA
32
33 Valve Type Body Size Body Material Angle 3" ASTM A182 F51
BODY

34 Inlet Connections Rating / Facing / Finishing 3" FLANGED RJ 2500 lb ASME B16.34 / FLANGED / RJ
35 Outlet Connect. Port Size Bonnet 3" FLANGED RJ 3" One Piece- ASTM A995 GR.1B
36 Packing Lubricator NACE Requirem. VTA VTA No
37 Plug Characteristic Leakage Class Cage type or VTA Equal % ANSI/FCI 70.2 Class IV
TRIM

38 Seat Material Plug Material Stem Material DUPLEX DUPLEX DUPLEX

VALVE 39 Cage Material DUPLEX


(SEE gen. 40 Type Size Max Shut-Off DP ELECTRIC (See Note 2) VTA 347 barg
ACTUAT.

note 1,2) 41 Flow Action To On Power Failure Signal Actuator CLOSE FL barg N/A
42 Positioner Type Input Signal Air Supply Press. N/A 4-20mA barg
43 Ex Execution Electrical Conn. Ex Certificate Ex-d NPT threaded NEC 505 (or IECEx)
44 Handwheel Jacket Limit Switches Required N/A T21000ZSH/ZSL 3001
ACCESSOR.

45 Solenoid Valve Position Transm. Filter Regulator N/A T21000ZT 3001 N/A
46 Air Volume Tank LOCK-UP Others N/A N/A Travel Indicator
47 Comm. Interface MODBUS TCP/IP (redundant)
48 Manufacturer Supplier TBD TBD
MANAGEMENT
DATA
49 Valve Model Actuator Model VTA VTA
50 Purchase Order Number Quantity TBD 1
Note: 1) Valve sizing calculations is preliminary and shall be determined by the Manufacturer.
2) Electrical actuator shall be equipped with position and torque sensing equipment, motor protection, logic control and digital comm. capability.
3) All materials and components shall be guaranteed for a Design temperature of 120° C.
4) Studs - A193 B8M Cl.2 & Nuts - A194 8M shall be zinc coated (hot-dip) to ASTM A-153.
Legend: TBD-To be Defined; VTA-Vendor to Advise/Confirm.

This document is property of Eni S.p.A.It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent.

You might also like