Professional Documents
Culture Documents
Tecoalli
Deck
EX-DE 00 20/12/2022 Issue for Comments M. Pupo F. Sarcina M. Diaz T. Flores F. Presta
Validity Revision
Contractor Contractor Contractor Company Company
Status Number Date Description
Prepared Checked Approved Checked Approved
Revision index
Company logo and business name LCI Activity Code Company Document ID:
LCI-MX-2022-0002
6008T2DIGA27014
Project Code
000481 Job N.:
Contractor logo and business name Contractor Document ID:
TC-001CM07TDS27014
Construcciones Mecanicas Monclova, SA de CV
Contract N.:
Vendor logo and business name Vendor Document ID
Superseded by N.
Technical Data Sheet (TDS) for Choke Valves Plant area Functional unit
n.a. n.a.
Software: Microsoft Excel File Name: 6008T2DIGA27014_EXDE00_06
This document is property of Eni S.p.A.
It shall neither be shown to Third Parties nor used for purposes other than those for which it has been sent.
Company Logo Contractor Logo Vendor Logo Validity Revision
Status Number
EX-DE 00
REVISION LIST
EX-DE 00 Issue for Comments
HOLD RECORD
REFERENCES
GENERAL NOTES
1)The actuator motorized must have the following local commands: Local / Remote selector, Stop, Opening & Closing of the
valve; Valve position (4-20mA HART SMART) and valve commands are Hardwired to DCS; In addition, redundant MODBUS
TCP/IP interface SHALL be provided.
2) Actuator, electric supply: 480VAC / 3 PH / 60 Hz, Degree of protection IP65 min..
3) Process data at the inlet of choke valve in nameplate case.
4) Density and viscosity of process data is for the liquid phase in nameplate case.
5) Valve shall be Fire safe ISO 10497.
6) Painting shall be according to Company Standard 29000.ENG.CPI.STD Painting for offshore and coastal structures and
project specification 6008T2DXST18504, Coating Specification for Tecoalli Topside & Jacket
Table 1
Proprierties at different pressure and temperature at inlet of choke valve
Pressure (barg) 24 25 44 164
T21000HCV 1001 Biphase : % wt Vapour 6,95 6,85 5,1 -
61°C Density @Oper. Cond. 821,4 820,5 802,1 741,6
Gas Molecular Weight 18,09 18,04 17,56 -
Spec Heat Ratio(Cp/Cv) 1,32 1,32 1,38 1,21
T21000HCV 2001 Biphase : % wt Vapour 7,2 7,1 5,4 -
67°C Density @Oper. Cond. 817,7 816,8 798,8 734,5
Gas Molecular Weight 18,31 18,26 17,72 -
Spec Heat Ratio(Cp/Cv) 1,31 1,32 1,37 -
T21000HCV 3001 Biphase : % wt Vapour 7,23 7,14 5,4 -
68°C Density @Oper. Cond. 817,1 816,2 798,3 733,3
Gas Molecular Weight 18,34 18,3 17,75 -
Spec Heat Ratio(Cp/Cv) 1,31 1,31 1,37 -
INDEX
1 COVER
2 REV LIST-HOLD RECORD
3 INDEX
4 T21000HCV 1001
5 T21000HCV 2001
6 T21000HCV 3001 (future)
EX-DE 00
4/6
6008T2DIGA27014 TC-001CM07TDS27014
34 Inlet Connections Rating / Facing / Finishing 3" FLANGED RJ 2500 lb ASME B16.34 / FLANGED / RJ
35 Outlet Connect. Port Size Bonnet 3" FLANGED RJ 3" One Piece- ASTM A995 GR.1B
36 Packing Lubricator NACE Requirem. VTA VTA No
37 Plug Characteristic Leakage Class Cage type or VTA Equal % ANSI/FCI 70.2 Class IV
TRIM
note 1,2) 41 Flow Action To On Power Failure Signal Actuator CLOSE FL barg N/A
42 Positioner Type Input Signal Air Supply Press. N/A 4-20mA barg
43 Ex Execution Electrical Conn. Ex Certificate Ex-d NPT threaded NEC 505 (or IECEx)
44 Handwheel Jacket Limit Switches Required N/A T21000ZSH/ZSL 1001
ACCESSOR.
45 Solenoid Valve Position Transm. Filter Regulator N/A T21000ZT 1001 N/A
46 Air Volume Tank LOCK-UP Others N/A N/A Travel Indicator
47 Comm. Interface MODBUS TCP/IP (redundant)
48 Manufacturer Supplier TBD TBD
MANAGEMENT
DATA
49 Valve Model Actuator Model VTA VTA
50 Purchase Order Number Quantity TBD 1
Note: 1) Valve sizing calculations is preliminary and shall be determined by the Manufacturer.
2) Electrical actuator shall be equipped with position and torque sensing equipment, motor protection, logic control and digital comm. capability.
3) All materials and components shall be guaranteed for a Design temperature of 120° C.
4) Studs - A193 B8M Cl.2 & Nuts - A194 8M shall be zinc coated (hot-dip) to ASTM A-153.
Legend: TBD-To be Defined; VTA-Vendor to Advise/Confirm.
This document is property of Eni S.p.A.It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent.
Company Logo Contractor Logo Vendor Logo Validity Revision
Status Number
EX-DE 00
5/6
6008T2DIGA27014 TC-001CM07TDS27014
34 Inlet Connections Rating / Facing / Finishing 3" FLANGED RJ 2500 lb ASME B16.34 / FLANGED / RJ
35 Outlet Connect. Port Size Bonnet 3" FLANGED RJ 3" One Piece- ASTM A995 GR.1B
36 Packing Lubricator NACE Requirem. VTA VTA No
37 Plug Characteristic Leakage Class Cage type or VTA Equal % ANSI/FCI 70.2 Class IV
TRIM
note 1,2) 41 Flow Action To On Power Failure Signal Actuator CLOSE FL barg N/A
42 Positioner Type Input Signal Air Supply Press. N/A 4-20mA barg
43 Ex Execution Electrical Conn. Ex Certificate Ex-d NPT threaded NEC 505 (or IECEx)
44 Handwheel Jacket Limit Switches Required N/A T21000ZSH/ZSL 2001
ACCESSOR.
45 Solenoid Valve Position Transm. Filter Regulator N/A T21000ZT 2001 N/A
46 Air Volume Tank LOCK-UP Others N/A N/A Travel Indicator
47 Comm. Interface MODBUS TCP/IP (redundant)
48 Manufacturer Supplier TBD TBD
MANAGEMENT
DATA
49 Valve Model Actuator Model VTA VTA
50 Purchase Order Number Quantity TBD 1
Note: 1) Valve sizing calculations is preliminary and shall be determined by the Manufacturer.
2) Electrical actuator shall be equipped with position and torque sensing equipment, motor protection, logic control and digital comm. capability.
3) All materials and components shall be guaranteed for a Design temperature of 120° C.
4) Studs - A193 B8M Cl.2 & Nuts - A194 8M shall be zinc coated (hot-dip) to ASTM A-153.
Legend: TBD-To be Defined; VTA-Vendor to Advise/Confirm.
This document is property of Eni S.p.A.It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent.
Company Logo Contractor Logo Vendor Logo Validity Revision
Status Number
EX-DE 00
6/6
6008T2DIGA27014 TC-001CM07TDS27014
34 Inlet Connections Rating / Facing / Finishing 3" FLANGED RJ 2500 lb ASME B16.34 / FLANGED / RJ
35 Outlet Connect. Port Size Bonnet 3" FLANGED RJ 3" One Piece- ASTM A995 GR.1B
36 Packing Lubricator NACE Requirem. VTA VTA No
37 Plug Characteristic Leakage Class Cage type or VTA Equal % ANSI/FCI 70.2 Class IV
TRIM
note 1,2) 41 Flow Action To On Power Failure Signal Actuator CLOSE FL barg N/A
42 Positioner Type Input Signal Air Supply Press. N/A 4-20mA barg
43 Ex Execution Electrical Conn. Ex Certificate Ex-d NPT threaded NEC 505 (or IECEx)
44 Handwheel Jacket Limit Switches Required N/A T21000ZSH/ZSL 3001
ACCESSOR.
45 Solenoid Valve Position Transm. Filter Regulator N/A T21000ZT 3001 N/A
46 Air Volume Tank LOCK-UP Others N/A N/A Travel Indicator
47 Comm. Interface MODBUS TCP/IP (redundant)
48 Manufacturer Supplier TBD TBD
MANAGEMENT
DATA
49 Valve Model Actuator Model VTA VTA
50 Purchase Order Number Quantity TBD 1
Note: 1) Valve sizing calculations is preliminary and shall be determined by the Manufacturer.
2) Electrical actuator shall be equipped with position and torque sensing equipment, motor protection, logic control and digital comm. capability.
3) All materials and components shall be guaranteed for a Design temperature of 120° C.
4) Studs - A193 B8M Cl.2 & Nuts - A194 8M shall be zinc coated (hot-dip) to ASTM A-153.
Legend: TBD-To be Defined; VTA-Vendor to Advise/Confirm.
This document is property of Eni S.p.A.It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent.