You are on page 1of 3

DESIGN OF TWO-WAY SLAB BY ACI-COEFFICIENTS

GROUND FLOOR SLAB


PANEL No : TARRACE

Input Data:
Slab Dimensions
Short Span = 12.75 ft
Long Span = 13.4271 ft
Span Ratio = 12.75 / 13.4271 = 0.95
Slab Thickness (reqd) = 2 x (12.75+13.4271) x 12 / 180 = 3.49 in
Slab Thickness (prvd) = 6. in

Edge Conditions
Short Span Edge Condition = One Edge Continuous
Long Span Edge Condition = One Edge Continuous

Applied Loads
Slab self wt = 75.00 psf
Service Dead Load = 20 psf
Service Live Load = 30 psf
Material Strengths
Concrete Strength = 4 ksi
Steel Yield Strength = 60 ksi

Design Moments
Loads
Total Ultimate DL =1.4(75 + 20) = 133 psf
Total Ultimate LL =1.7(30) = 51 psf
Total Ultimate Load =133 + 51 = 184 psf

Short Span Moments


Positive Moment DL Mua(dl)+ = 0.03 x 133 x 12.75^2 = 0.649 k-ft
Positive Moment LL Muall+ = 0.035 x 51 x 12.75^2 = 0.290 k-ft
Total Postive Short Span Moment Mua+ = ---------------------------------> = 0.939 k-ft

Negative Moment on Discontinuous Edge = 1/3 x 0.939 = 0.313 k-ft


Negative Moment on Continuous Edge = 0.055 x 184 x 12.75^2 = 1.645 k-ft

Long Span Moments


Positive Moment DL Mubdl+ = 0.024 x 133 x 13.4271^2 = 0.575 k-ft
Positive Moment LL Mubll+ = 0.029 x 51 x 13.4271^2 = 0.267 k-ft
Total Postive Long Span Moment Mub+ = ---------------------------------> = 0.842 k-ft

Negative Moment on Discontinuous Edge = 1/3 x 0.842 = 0.281 k-ft


Negative Moment on Continuous Edge = 0.045 x 184 x 13.4271^2 = 1.493 k-ft
DESIGN OF TWO-WAY SLAB BY ACI-COEFFICIENTS
GROUND FLOOR SLAB
PANEL No : TARRACE

Reinforcement Calculations
Along Short Span
Positive Steel
Mu=0.94 k-ft ; b=12 in ; d=5.063 in ; fc'=4ksi ; fy= 60 ksi
As+ = 0.85 x 4 / 60 x [1 - [1-2 x 12 x0.939/(0.9x0.85x4x12x5.063^2) ]^0.5 ] x 12 x 5.063
= 0.041 sq.in.
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As+ = 0.130 sq.in. (#3 @ 10 in )
Negative Steel
Mu=0.31 k-ft ; b=12 in ; d=5.063 in ; fc'=4ksi ; fy= 60 ksi
As- = 0.85 x 4 / 60 x [1 - [1-2 x 12 x0.313/(0.9x0.85x4x12x5.063^2) ]^0.5 ] x 12 x 5.063
= 0.014 sq.in.
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As- = 0.130 sq.in. (#3 @ 10 in )
Negative Steel
Mu=1.65 k-ft ; b=12 in ; d=5.063 in ; fc'=4ksi ; fy= 60 ksi
As- = 0.85 x 4 / 60 x [1 - [1-2 x 12 x1.645/(0.9x0.85x4x12x5.063^2) ]^0.5 ] x 12 x 5.063
= 0.073 sq.in.
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As- = 0.130 sq.in. (#3 @ 10 in )

Along Long Span


Positive Steel
Mu=0.84 k-ft ; b=12 in ; d=4.688 in ; fc'=4ksi ; fy= 60 ksi
As+ = 0.85 x 4 / 60 x [1 - [1-2 x 12 x0.842/(0.9x0.85x4x12x4.688^2) ]^0.5 ] x 12 x 4.688
= 0.040 sq.in
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As+ = 0.130 sq.in. (#3 @ 10 in )
Negative Steel
Mu=0.28 k-ft ; b=12 in ; d=5.063 in ; fc'=4ksi ; fy= 60 ksi
As- = 0.85 x 4 / 60 x [1 - [1-2 x 12 x0.281/(0.9x0.85x4x12x5.063^2) ]^0.5 ] x 12 x 5.063
= 0.012 sq.in
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As- = 0.130 sq.in. (#3 @ 10 in )
Negative Steel
Mu=1.49 k-ft ; b=12 in ; d=5.063 in ; fc'=4ksi ; fy= 60 ksi
As- = 0.85 x 4 / 60 x [1 - [1-2 x 12 x1.493/(0.9x0.85x4x12x5.063^2) ]^0.5 ] x 12 x 5.063
= 0.066 sq.in
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As- = 0.130 sq.in. (#3 @ 10 in )

Shear Check
Total load on the panel = 12.75 x 13.4271 x 184 = 31.4 kips

Shear Capacity of the section fVc = 0.85 x 2 x ( 4000 )^½ x 12 x 5 / 1000 = 6.45 k/ft

Shear along short side Vua = ( 0.45 x 31.4 ) / (2 x 12.75 ) = 0.55 k/ft <6.45 k/ft…. (O.K.)
Shear along long side Vub = ( 0.55 x 31.4 ) / ( 2 x 13.4271 ) = 0.64 k/ft <6.45 k/ft….(O.K).
#############################################################################
#####################################################################################################

# 3 @ 10.0 in

# 3 @ 10.0 in

12.75 ft
# 3 @ 10. in

# 3 @ 10. in

# 3 @ 10. in
# 3 @ 10.0 in

13.43 ft

SCHEMATIC DIAGRAM OF REINFORCED SLAB


GROUND FLOOR SLAB
PANEL NO: TARRACE