DATA Input Screen

Enter data in the cells shaded blue

Chilled Water Plant Energy Analysis


IPC 11550 with Hartman LOOP Technology
Project Name:
Contact:
Date Prepared:
City of Construction
State / Province
Country
Sales Person
Units Imperial

Design Day Wet Bulb Temp Max


Design Day Dry Bulb T Max
Design Day ECWT (LTWT)

Chilled Water Plant Energy Savings Analysis

Plant Configuration Data


Design Day Building Load
Chiller name plate capacity (each)
General Bldg & Plant Data

Total Number of Chillers (duty and standby)


Number of Duty Chillers (total)
Total installed chiller capacity (Load plus standby)
Chiller load if all duty and stdby chillers operate
Design System Delta T (across chiller plant)
Chilled water Pump design point head rating (addition of all pumps heads - VP or VPVS chilled water
Approximate Primary Pump Head
Project Input and Description data

Approximate Secondary Pump Head


Cooling Tower Design Delta T
Tower Minimum Fan Speed
Cooling Tower Fan design point HP draw
Power cost ($ per kW-hr)
BASE CASE system configuration
BASE CASE Plant Data

BASE CASE Chiller Type, cintrifugal water cooled (make, model)


BASE Case tower flow
Base Case Tower (reset?)
Base Case Configuration
Project Input and Descr

BASE CASE Plant Data


IPC Ultra Efficient Plant Data Final system configuration
Cooling Towers Design Day Flow (IPC plant) User Defined Towe
Cooling Tower Flow Turndown capacity (% of full flow)
Chiller Type, centrifugal water cooled (make, model)
Chiller turn down limit by VS (% of DD Building load/ Qty Duty chillers)
Chiller Minimum Flow rating (% of full flow)
Cooling Tower Pump design point head rating
IPC 11550 system confiugrations
Imperial

F
95.0 F
85.0 F

Hours / day (12 or 24)


alysis Months / year
Days / week

Value

VP or VPVS chilled water side only)

9.99
25%
User Defined Fan Draw

Constant Primary Constant Secondary


High Performance Oil Free Mag Bearing Variable Spe
Let Program Estimate
Yes (80 F)
Variable Primary Flow
User Defined Tower Flow User Defined Tower Flow

Typ. Fixed Speed Centrifugal R134a (<2004)

70
Variable speed primary flow system, variable flow cooling towers, cooling
towers headered with isolation valves, dedicated VPF chilled water pumps, 2
VS chillers, with variable speed fans on cooling towers. Hartman LOOP
plant control.
Quote Ref #:

DD CHWST SP 42.0 F
Max CHWST 46.4 F
Chiller Min ECWT 55.04 F
Is tower counter flow counter flow

24
12
7

Unit
tons
tons
WARNING, # of Chillers Must be >1
WARNING, # of Chillers Must be >1
tons
tons
Degrees F
ft
ft
ft
Degrees F
%
fined Fan Draw

ry Constant Secondary
Mag Bearing Variable Speed Chiller
gram Estimate
e Primary Flow
ined Tower Flow
%

%
%
ft