You are on page 1of 1

Scale Controlling Chemical Additives for

Phosphoric Acid Production Plants


John Carr, Lei Zhang, Matthew Davis, S.A. Ravishankar, and Greg Flieg

Cytec has developed a novel family of antiscalants, PHOSFLOW®, that reduces the fluorosilicate,
calcium sulfate and aluminate scale formation in phosphoric acid operations allowing for longer
cycle times, increased production, and reduced maintenance time.

1. Introduction
Accumulation of scale is a perennial problem in phosphoric costs, lost production due to downtime, and downgraded
acid production processes. The large quantities of dissolved products from lower concentration due to poor heat
and un-dissolved species present during the digestion and transfer[3-4]. A rough calculation of potential production gain
concentration process lead to the formation of scale deposits from extending the operating cycle of a heat exchanger is
on the filters, pipelines carrying the acid, evaporators, illustrated in Table 1 assuming 50 weeks/year operation with
heat exchangers and coolers [1-2]. Scale buildup can cause a a capacity of 300 T P2O5/day (i.e. 105 000 T/year or 12.5 T/h)
number of operational issues such as plugging of equipment, with a shutdown frequency of every 2 weeks and a shutdown
inefficient feed rate to the evaporators, increased utility duration of 20 hours.

Table 1. Production Gain by Extending Cycle

New shut down frequency Production time saved Merchant grade acid production increase
(from 2 weeks to) (hrs/year) (T/year) (%)
4 weeks 250 3125 3.0

5 weeks 300 3750 3.6

6 weeks 333 4167 4.0

Cytec has developed a novel family of antiscalants, two distinct points in the phosphoric acid production
PHOSFLOW®, that reduces the fluorosilicate, calcium sulfate process. No negative downstream effects were observed.
and aluminate scale formation in phosphoric acid operations The antiscalant is easily applied to the process through a
allowing for longer cycle times, increased production, and piston pump requiring minimal capital investment. This
reduced maintenance time. The technology has been article will summarize the application of this technology to a
demonstrated via three commercial scale plant trials at commercial phosphoric acid heat exchanger and feed line.