TECHNICAL DOCUMENTS

DESCRIPTION OF
STRUCTURAL CALCULATION

Project/ Dự án : THE LANCASTER LUMINAIRE

Invesment/ Chủ Đầu Tư : TAN PHU LONG JOINT STOCK COMPANY

Items/ Hạng mục : CAST-IN CHANEL (LEVEL 12 TO LEVEL 25)

Address/ Địa điểm : DONG DA DISTRIC, HA NOI PROVINCE, VIET NAM

04/2021
DESCRIPTION OF STRUCTURAL CALCULATION

CONTENTS/ MỤC LỤC


I. BASIS OF CALCULATION/ CƠ SỞ TÍNH TOÁN ................................................................................................. 3
1. Standards and codes/ Tiêu chuẩn áp dụng ............................................................................................................ 3
2. Material properties/ Tính chất vật liệu .................................................................................................................... 3
3. Design load/ Tải thiết kế ......................................................................................................................................... 4
4. Cast-in channel prototy/ Phân chia khu vực cast-in ............................................................................................... 6
5. Annalysis of embeded level 12 to level 25/ Tính toán kiểm tra cast-in tầng 12 đến tầng 25 .................................. 8
5.1. Reference drawing:/ Bản vẽ định vị loại cast-in......................................................................................... 9
5.2. Computation of load/ Tính toán tải trọng tác dụng .................................................................................13
5.3. Load capacity Analysis of Channel./ TÍnh toán khả năng chịu lực của cast-in .......................................28

II. ANNEX/ PHỤ LỤC .................................................................................................................................... 29


1. Annex 1: Calculate wind load for base tender arcording to TCVN 2737/ Phụ lục 1: Tính toán tải gió phương án cơ
sở theo TCVN 2737 ...................................................................................................................................................29
2. Annex 2: Calculate seismic load/ Phụ lục 2: Tính toán tải động đất. ....................................................................32
3. Annex 3: Load capacity analysis of cast-in channel at location 1 level 12 to level 18/ Phụ lục 3: Phân tích khả năng
chịu lực của cast-in channel vị trí 1 tầng 12 đến tầng 18 ..........................................................................................36
4. Annex 4: Load capacity analysis of cast-in channel at location 1 level 19 to level 25/ Phụ lục 4: Phân tích khả năng
chịu lực của cast-in channel vị trí 1 tầng 19 đến tầng 25 ..........................................................................................37
5. Annex 5: Load capacity analysis of cast-in channel at location 2 level 12 to level 25/ Phụ lục 5: Phân tích khả
năng chịu lực của cast-in channel vị trí 2 tầng 12 đến tầng 25..................................................................................38
6. Annex 6: Load capacity analysis of cast-in channel at location 3 level 12 to level 25/ Phụ lục 6: Phân tích khả năng
chịu lực của cast-in channel vị trí 3 tầng 12 đến tầng 25 ..........................................................................................39
7. Annex 7: Load capacity analysis of cast-in channel at location 4 level 12 to level 25/ Phụ lục 7: Phân tích khả
năng chịu lực của cast-in channel vị trí 4 tầng 12 đến tầng 25..................................................................................40

Page 2/40
DESCRIPTION OF STRUCTURAL CALCULATION

I. BASIS OF CALCULATION/ CƠ SỞ TÍNH TOÁN


1. Standards and codes/ Tiêu chuẩn áp dụng

 Standard TCVN 2737:1995 – Loads and Effects – Design Standard/


Tiêu chuẩn TCVN 2737:1995 – Tải trọng và tác động – Tiêu chuẩn thiết kế;

 Standard TCVN 9386:2012 – Design of structures for earthquake resistances/


Tiêu chuẩn TCVN 9386:2012 – Thiết kế công trình chịu động đất;

 Standard TCVN 5575:2012 – Steel structures – Design standard/


Tiêu chuẩn TCVN 5575:2012 – Kết cấu thép – Tiêu chuẩn thiết kế;

 EN-1992-4 Eurocode 2. Design of concrete structures. Design of fasterning for use in concrete/ Tiêu
chuẩn châu Âu Eurocode 2, thiết kế kết cấu bê tông. Thiết kế hệ neo trong bê tông.

 Façade project specification. / Bảng tiêu chí kỹ thuật hệ mặt dựng của dự án

 Technical document of supplier/


Tài liệu kỹ thuật của các nhà cung cấp.

2. Material properties/ Tính chất vật liệu

 Properties of Steel/ Tính chất vật liệu thép

Specific weight/ Khối lượng riêng 7850 kgf/m3


Physical properties/ Modulus of elasticity/ Module đàn hồi E = 206000N/mm2
Tính chất vật lý Coefficient of the thermal expansion/
17 x 10-6 Per degree C
Hệ số giãn nở nhiệt
Allowable stress/ Ứng suất cho phép : N/mm2
Alloy/ Hợp kim
Pb, Bending stress/ Ứng suất uốn Pv, Shear stress/ Ứng suất cắt
S275 275 145

 Properties of Aluminium/ Tính chất vật liệu nhôm

Specific weight/ Khối lượng riêng 2710 kgf/m3


Physical properties/ Modulus of elasticity/ Module đàn hồi E = 70000N/mm2
Tính chất vật lý Coefficient of the thermal expansion/
23 x 10-6 Per degree C
Hệ số giãn nở nhiệt

 Properties of glass/ Tính chất vật liệu kính

Specific weight/ Khối lượng riêng 2560 kgf/m3


Physical properties/ Modulus of elasticity/ Module đàn hồi E = 72000N/mm2
Tính chất vật lý Coefficient of the thermal expansion/
9 x 10-6 Per degree C
Hệ số giãn nở nhiệt

Page 3/40
DESCRIPTION OF STRUCTURAL CALCULATION

3. Design load/ Tải thiết kế

Dead load (DL)/ Tải trọng bản thân

The total self-weight shall be used in combination with wind load and other applied loads in the design of all
members/ Tải trọng bản thân được tổ hợp với tải gió và các tải khác trong thiết kế.

Wind load (WL)/ Tải gió

Design windload is calculated base on Viet Nam building code TCVN 2737-1995 “Load and effect – Design
Standard” which show more detail in annex 2/ Tải gió thiết kế cho phương án đề xuất được tính toán dựa trên Tiêu
Chuẩn Việt Nam 2737-1995 “Tải trọng và tác động – Tiêu chuẩn thiết kế”, xem chi tiết trong phụ lục 2.
+ Tải trọng gió tác dụng tại tầng 18

 At corner zone of building/ Khu vực góc tòa nhà:


Wn = -2.66 kPa

 Non-corner zones/ Các khu vực khác:


Wp = 1.77 kPa
Wn = -1.33 kPa

+ Tải trọng gió tác dụng tại tầng 25

 At corner zone of building/ Khu vực góc tòa nhà:


Wn = -2.78 kPa

 Non-corner zones/ Các khu vực khác:


Wp = 1.85 kPa
Wn = -1.39 kPa

Page 4/40
DESCRIPTION OF STRUCTURAL CALCULATION

Seismic load (SL)/ Tải động đất.

Refer to annex 2/ Theo phụ lục 2:

 The seismic presssure applied to the module is equal to 0.24 of the element weight/ Áp lực tải động
động đất tác dụng vào module bằng 0.24 lần khối lượng của các phần tử

Load combination (COM)/ Tổ hợp tải.

 Load case 1: 1.4DL + 1.4 WLP

 Load case 2: 1.4DL + 1.4 WLs

 Load case 3: 1.2DL + 1.2 WLs + 1.2x0.8xSL


Where:
DL = Dead Load. / Tải trọng bản thân
WLP = Wind Load. / Tải trọng gió đẩy
WLS = Wind Load. / Tải trọng gió hút
SL = Seismic Load. Tải trọng động đất

Page 5/40
DESCRIPTION OF STRUCTURAL CALCULATION

4. Cast-in channel prototy/ Phân chia khu vực cast-in

BUILDING ELEVATION./ MẶT ĐỨNG TÒA NHÀ

Page 6/40
DESCRIPTION OF STRUCTURAL CALCULATION

CAST-IN TYPLE LOCATION PLAN./ MẶT BẰNG VỊ TRÍ CAST-IN

Page 7/40
DESCRIPTION OF STRUCTURAL CALCULATION

5. Annalysis of embeded level 12 to level 25/ Tính toán kiểm tra cast-in tầng 12 đến tầng 25
PANEL DIMENSION DEAD FSW WIND LOAD WIND FWL FINS FFL SEISMIS FSL
LOCATION DISCRIPTION LOADCASE ADJACENT CALCULATION RESULT
mm mm KICKER (N) KPA (N) (N) (N)
PANEL
LOADCASE 1 1234 3800 0 3800 3841 1.77 8300 1681.5
LOCATION 1 TOP FLOOR SEE CALCULATION
LOADCASE 2 1234 3800 0 3800 3841 2.66 12473 1681.5
level 12 to level 18 TYPICAL RESULT IN ANNEX 3
LOADCASE 3 1234 3800 0 3800 3841 2.66 12473 1681.5 922
LOADCASE 1 1234 3800 0 3800 3841 1.85 8675 1757.5
LOCATION 1 TOP FLOOR SEE CALCULATION
LOADCASE 2 1234 3800 0 3800 3841 2.78 13036 1757.5
level 19 to level 25 TYPICAL RESULT IN ANNEX 4
LOADCASE 3 1234 3800 0 3800 3841 2.78 13036 1757.5 922
LOADCASE 1 1190 3800 0 3800 3841 1.77 8004 1681.5
LOCATION 2 BEAM SIDE SEE CALCULATION
LOADCASE 2 1190 3800 0 3800 3841 2.66 12029 1681.5
level 12 to level 25 TYPICAL RESULT IN ANNEX 5
LOADCASE 3 1190 3800 0 3800 3841 2.66 12029 1681.5 922
1190 3800 0 3800 1920 1.77 4002
LOADCASE 1
1234 3800 0 3800 1920 1.77 4150
LOCATION 3 BEAM SIDE 1190 3800 0 3800 1920 2.66 6014 SEE CALCULATION
LOADCASE 2
level 12 to level 25 CORNER 1234 3800 0 3800 1920 2.66 6237 RESULT IN ANNEX 6
1190 3800 0 3800 1920 2.66 6014 461
LOADCASE 3
1234 3800 0 3800 1920 2.66 6237 461
1213 3800 0 3800 1920 1.77 4079
LOADCASE 1
1260 3800 0 3800 1920 1.77 4237
LOCATION 4 TOP FLOOR 1213 3800 0 3800 1920 2.66 6131 SEE CALCULATION
LOADCASE 2
level 12 to level 25 CORNER 1260 3800 0 3800 1920 2.66 6368 RESULT IN ANNEX 7
1213 3800 0 3800 1920 2.66 6131 461
LOADCASE 3
1260 3800 0 3800 1920 2.66 6368 461

Summary table of cast-in calculation

Page 8/40
DESCRIPTION OF STRUCTURAL CALCULATION

5.1. Reference drawing:/ Bản vẽ định vị loại cast-in

Page 9/40
DESCRIPTION OF STRUCTURAL CALCULATION

Page 10/40
DESCRIPTION OF STRUCTURAL CALCULATION

Page 11/40
DESCRIPTION OF STRUCTURAL CALCULATION

Page 12/40
DESCRIPTION OF STRUCTURAL CALCULATION

5.2. Computation of load/ Tính toán tải trọng tác dụng


Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 1 – Load case 1 LUMINARE
(level 12-18) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 1.77
Width of panel: W(mm) = 1234
Heigh of panel: H(mm) = 3800
Depth of fins: D(mm) = 250
FSW (N) = 3841
FWLP (N) = WLxHxW = 8300
FFL (N) = WLxHxD = 1682

Load case: 1.4FSW+1.4(FWLP+FFL)

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 3.1)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 13/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 1 – Load case 2 LUMINARE
(level 12-18) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 2.66
Width of panel: W(mm) = 1234
Heigh of panel: H(mm) = 3800
Depth of fins: D(mm) = 250
FSW (N) = 3841
FWLS (N) = WLxHxW = 12473
FFL (N) = WLxHxD = 1682

Load case: 1.4FSW+1.4(FWLS+FFL)

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 3.2)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 14/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 1 – Load case 3 LUMINARE
(level 12-18) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 2.66
Width of panel: W(mm) = 1234
Heigh of panel: H(mm) = 3800
Depth of fins: D(mm) = 250
FSW (N) = 3841
FWLS (N) = WLxHxW = 12473
FFL (N) = WLxHxD = 1682
FSL (N) = 0.24FSW = 922

Load case:
1.2FSW+1.2(FWLS+FFL)+1.2x0.8FSL

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 3.3)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 15/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 1 – Load case 1 LUMINARE
(level 19-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 1.85
Width of panel: W(mm) = 1234
Heigh of panel: H(mm) = 3800
Depth of fins: D(mm) = 250
FSW (N) = 3841
FWLP (N) = WLxHxW = 8675
FFL (N) = WLxHxD = 1758

Load case: 1.4FSW+1.4(FWLP+FFL)

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 4.1)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 16/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 1 – Load case 2 LUMINARE
(level 19-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 2.78
Width of panel: W(mm) = 1234
Heigh of panel: H(mm) = 3800
Depth of fins: D(mm) = 250
FSW (N) = 3841
FWLS (N) = WLxHxW = 13036
FFL (N) = WLxHxD = 1758

Load case: 1.4FSW+1.4(FWLS+FFL)

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 4.2)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 17/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 1 – Load case 3 LUMINARE
(level 19-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 2.5
Width of panel: W(mm) = 1234
Heigh of panel: H(mm) = 3800
Depth of fins: D(mm) = 250
FSW (N) = 3841
FWLS (N) = WLxHxW = 13036
FFL (N) = WLxHxD = 1758
FSL (N) = 0.24FSW = 922

Load case:
1.2FSW+1.2(FWLS+FFL)+1.2x0.8FSL

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 4.3)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 18/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 2 – Load case 1 LUMINARE
(level 12-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 1.85
Width of panel: W(mm) = 1234
Heigh of panel: H(mm) = 3800
Depth of fins: D(mm) = 250
FSW (N) = 3841
FWLP (N) = WLxHxW = 8366
FFL (N) = WLxHxD = 1758

Load case: 1.4FSW+1.4(FWLP+FFL)

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 5.1)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 19/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 2 – Load case 2 LUMINARE
(level 12-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 2.78
Width of panel: W = 1234
Heigh of panel: H(mm) = 3800
Depth of fins: D(mm) = 250
FSW (N) = 3841
FWLS (N) = WLxHxW = 12571
FFL (N) = WLxHxD = 1758

Load case: FSW+1.4(FWLS+FFL)

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 5.2)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 20/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 2 – Load case 3 LUMINARE
(level 12-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 2.78
Width of panel: W = 1234
Heigh of panel: H(mm) = 3800
Depth of fins: D(mm) = 250
FSW (N) = 3841
FWLS (N) = WLxHxW = 12571
FFL (N) = WLxHxD = 1758
FSL (N) = 0.24Fsw = 922
Load case:
1.2FSW+1.2(FWLS+FFL)+1.2x0.8FSL

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 5.3)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 21/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 3 – Load case 1 LUMINARE
(level 12-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 1.85
Width of panel: W(mm) = 1234
Heigh of panel: H(mm) = 3800
FSW (N) = 1920
FWLP (N) = WLxHxW/2 = 4338

Loadcase: 1.4FSW+1.4FWLP

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 6.1)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 22/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 3 – Load case 2 LUMINARE
(level 12-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 2.78
Width of panel: W(mm) = 1234
Heigh of panel: H(mm) = 3800
FSW (N) = 1920
FWLS (N) = WLxHxW/2 = 6518

Loadcase: FSW+1.4FWLS

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 6.2)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 23/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 3 – Load case 3 LUMINARE
(level 12-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 2.78
Width of panel: W(mm) = 1234
Heigh of panel: H(mm) = 3800
FSW (N) = 1920
FWLS (N) = WLxHxW/2= 6518
FSL (N) = 0.24Fsw = 461
Loadcase:
1.2FSW+1.2FWLS+1.2x0.8FSL

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 6.3)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 24/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 4 – Load case 1 LUMINARE
(level 12-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 1.85
Width of panel: W(mm) = 1260
Heigh of panel: H(mm) = 3800
FSW (N) = 1920
FWLP (N) = WLxHxW/2 = 4429

Loadcase:
1.4FSW+1.4FWLP

Moment eccentricity:

MDL (kN.m) = FSW.d = 0.03

MWLP (kN.m) = FWLP.d = 0.071

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 7.1)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 25/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 4 – Load case 2 LUMINARE
(level 12-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 2.78
Width of panel: W(mm) = 1260
Heigh of panel: H(mm) = 3800
FSW (N) = 1920
FWLS (N) = WLxHxW/2 = 6655

Loadcase: FSW+1.4FWLS

Moment eccentricity:

MDL (kN.m) = FSW.d = 0.03

MWLS (kN.m) = FWLS.d = 0.106

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 7.2)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 26/40
DESCRIPTION OF STRUCTURAL CALCULATION

Project Name:
STRUCTURAL ENGINEERING CALCULATION
LANCASTER
Subject: Cast in channel at location 4 – Load case 3 LUMINARE
(level 12-25) Typical Unitized Curtain Wall

Parameter:
Wind load: WL (kpa) = 2.78
Width of panel: W(mm) = 1260
Heigh of panel: H(mm) = 3800
FSW (N) = 1920
FWLS (N) = WLxHxW/2 = 6655
FSL (N) = 0.24Fsw = 461
Loadcase:
1.2FSW+1.2FWLS+1.2x0.8FSL

Moment eccentricity:

MDL (kN.m) = FSW.d = 0.03

MWLS (kN.m) = FWLS.d = 0.106

MSL (kN.m) = FSL.d = 0.007

Result:
Calculation cast-in channel by Hilti
Profis software:
(Refer to Calculation appendix 7.3)

Prepared by Checked by Date Ref. No.

Rev. No. Sheet. No.

Page 27/40
DESCRIPTION OF STRUCTURAL CALCULATION

5.3. Load capacity Analysis of Channel./ TÍnh toán khả năng chịu lực của cast-in

Refer to annex 3,5,6,7/Theo phụ lục 3,5,6,7:


+ All location shall be use of cast-in channel type HAC/40/91/300F and T-bolt M16x50
Refer to annex 4/Theo phụ lục 4:
+ Location 1 from level 19 to level 25 shall be use of cast-in channel type HAC/50/106/300F and T-bolt M16x50

Page 28/40
DESCRIPTION OF STRUCTURAL CALCULATION

II. ANNEX/ PHỤ LỤC


1. Annex 1: Calculate wind load for base tender arcording to TCVN 2737/ Phụ lục 1: Tính toán tải gió phương án cơ sở theo TCVN 2737

Height of Builiding/ Chiều cao tòa nhà: H = 114.4m


Width of Building/ Chiều rộng tòa nhà: D = 40.0m
Exposure category of Tower/ Dạng địa hình của công trình: B
Design service life of building/ Tuổi thọ thiết kế của công trình: 50 years

The static component of wind load/ Tải trọng tính toán gió tĩnh
Wt = n.Wo.k.c
+ Wo: Value of wind pressure subject /
Design wind velocity V3s = 45m/s as per specification.
Wo = 0.0613 x V3s2 = 0.0613x 452 = 124 daN/m2
+ c: Aerodynamic coefficient/ Hệ số khí động học

Table 6/ Tra Bảng 6, TCVN 2737:1995  cp = +0.8/ cn = -0.6


+ k: Coeffient which considerate to change of wind pressure subject to height/
Hệ số tính đến sự thay đổi của áp lực gió theo chiều cao

Table 5/ Tra Bảng 6, TCVN 2737:1995 k


+ n: The coefient of wind load reliability/ Hệ số quy đổi gió
Incase serviceable wind load/ Trường hợp tải gió tiêu chuẩn: n = 1
Incase ultimate wind load/Trường hợp tải gió tính toán: n = 1.2 (design service life of building is 50 years/ Tuổi thọ thiết kế của công trình là 50 năm)

The dynamic component of wind load/ Tải trọng tính toán động:

Wd = Wt . .
+ ζ : Dynamical factor/ Hệ số áp lực

Page 29/40
DESCRIPTION OF STRUCTURAL CALCULATION

Table 8/ Tra Bảng 8, TCVN 2737:1995 ζ


+ ν : Space correlated coefficient of dynamic pressure of wind load/ Hệ số tương quan của gió động

Table 10/ Tra Bảng 10, TCVN 2737:1995 ν

Gross wind load/ Áp lực gió tổng (W):

W = Wt + Wd

Page 30/40
DESCRIPTION OF STRUCTURAL CALCULATION

Wind load table at each floor level/ Áp lực gió tác dụng tại mỗi tầng
Design windload
Level Height Static (daN/m ) 2
Dynamic (daN/m2) Total=Static+Dynamic (daN/m 2)
Floor k
(m) (m) Negative Negative Negative Negative Negative Negative
Positive Positive Positive
Non-corner Corner Non-corner Corner Non-corner Corner
1 1.00 6.10
2 7.10 3.80 0.930 92.35 -69.26 -138.53 33.51 -25.13 -50.27 125.86 -94.40 -188.79
3 10.90 3.80 1.014 100.70 -75.53 -151.05 34.95 -26.21 -52.43 135.65 -101.74 -203.48
4 14.70 3.80 1.075 106.75 -80.06 -160.13 35.85 -26.89 -53.78 142.60 -106.95 -213.90
5 18.50 3.80 1.115 110.73 -83.05 -166.10 35.91 -26.93 -53.87 146.64 -109.98 -219.96
6 22.30 3.80 1.151 114.30 -85.73 -171.45 36.15 -27.11 -54.23 150.45 -112.84 -225.68
7 26.10 3.80 1.185 117.68 -88.26 -176.52 36.47 -27.35 -54.71 154.15 -115.61 -231.23
8 29.90 3.80 1.219 121.05 -90.79 -181.58 36.74 -27.56 -55.11 157.79 -118.34 -236.69
9 33.70 3.80 1.242 123.34 -92.51 -185.01 36.67 -27.50 -55.01 160.01 -120.01 -240.02
10 37.50 3.80 1.265 125.62 -94.22 -188.43 36.62 -27.47 -54.93 162.24 -121.68 -243.36
11 41.30 3.80 1.288 127.91 -95.93 -191.87 36.63 -27.47 -54.95 164.54 -123.41 -246.81
12 45.10 3.80 1.311 130.19 -97.64 -195.29 36.81 -27.61 -55.22 167.00 -125.25 -250.50
13 48.90 5.35 1.333 132.37 -99.28 -198.56 36.95 -27.71 -55.43 169.32 -126.99 -253.98
14 54.25 3.80 1.357 134.76 -101.07 -202.14 36.98 -27.74 -55.47 171.74 -128.81 -257.61
15 58.05 3.80 1.372 136.25 -102.19 -204.38 36.91 -27.68 -55.37 173.16 -129.87 -259.74
16 61.85 3.80 1.386 137.64 -103.23 -206.46 36.83 -27.62 -55.25 174.47 -130.85 -261.71
17 65.65 3.80 1.400 139.03 -104.27 -208.55 36.79 -27.59 -55.19 175.82 -131.87 -263.73
18 69.45 3.80 1.413 140.32 -105.24 -210.48 36.77 -27.58 -55.16 177.09 -132.82 -265.64
19 73.25 3.80 1.426 141.61 -106.21 -212.42 36.69 -27.52 -55.04 178.30 -133.73 -267.45
20 77.05 3.80 1.440 143.00 -107.25 -214.50 36.63 -27.47 -54.95 179.63 -134.72 -269.45
21 80.85 3.80 1.453 144.29 -108.22 -216.44 36.54 -27.41 -54.81 180.83 -135.62 -271.25
22 84.65 3.80 1.464 145.38 -109.04 -218.07 36.57 -27.43 -54.86 181.95 -136.46 -272.93
23 88.45 3.80 1.475 146.48 -109.86 -219.72 36.53 -27.40 -54.80 183.01 -137.26 -274.52
24 92.25 3.80 1.487 147.67 -110.75 -221.51 36.51 -27.38 -54.77 184.18 -138.14 -276.27
25 96.05 3.80 1.498 148.76 -111.57 -223.14 36.46 -27.35 -54.69 185.22 -138.92 -277.83
26 99.85 6.000 1.510 149.95 -112.46 -224.93 36.43 -27.32 -54.65 186.38 -139.79 -279.57
27 105.85 3.350 1.524 151.34 -113.51 -227.01 36.37 -27.28 -54.56 187.71 -140.78 -281.57
28 109.20 2.650 1.532 152.14 -114.11 -228.21 36.30 -27.23 -54.45 188.44 -141.33 -282.66
TERRACE 111.85 2.550 1.538 152.73 -114.55 -229.10 36.25 -27.19 -54.38 188.98 -141.74 -283.47
ROOF 114.40 1.545 153.43 -115.07 -230.15 36.23 -27.17 -54.35 189.66 -142.25 -284.49

Page 31/40
DESCRIPTION OF STRUCTURAL CALCULATION

2. Annex 2: Calculate seismic load/ Phụ lục 2: Tính toán tải động đất.

CALCULATING SEISMIC LOAD

- The height of the non-structural element: z = 113.4 m


- The height of building: H = 113.4 m
- The weight of element: Wa
- The reference peak ground acceleration on type A ground:
(Dong Da District – Ha Noi)
Follow TCVN 9386-2002, Annex H: agR = 0.0892 g
- Follow TCVN 9386-2002, Annex F ⇒ The building construction type:I
Follow TCVN 9386-2002, Annex E ⇒An importance factor γ1 = 1.25
- The design ground acceleration type A ground: ag = γ1.agR = 1.25 agR
- Follow TCVN 9386-2002, Table 3.1 ⇒ Soild type: D
Follow TCVN 9386-2002, Table 3.2 ⇒ Soil factor: S = 1.35
- Fundamental vibration period of element: Ts = 0.2 s
- The allowable horizontal displacement at building roof: d = 0.2268 m
Follow TCXD 198-1997, Section 2.6.3 ⇒ d = H/500
- Fundamental vibration period of building: T1  2 d  0.9525 s
- The ratio of the design ground acceleration type A ground (ag) to
the acceleration of gravity (g): α = 0.1115
- The seismic coefficient:
 
 3.  1  z  
  H 
Sa   .S.  2
 0.5  0.4808
 1   1  Ta  
  T1  

- Follow TCVN 9386-2002, Section 4.3.5.3


⇒ The importance factor of the element: γa = 1
- Follow TCVN 9386-2002, Section 4.3.5.4
⇒ The behaviour factor of the element: qa = 2
- The seismic pressure applied to the building:
Sa .Wa . a
Fa   0.24 Wa
qa

⇒The seismic presssure applied to the module is equal to 0.24 of the element weight

Page 32/40
DESCRIPTION OF STRUCTURAL CALCULATION

Computation dead load of panel/ Tính toán tải trọng bản thân panel
No. Material Thk.(mm) Width(mm) Height(mm) Weight(kg)
1 Glass 33.52(8+6x2+12+1.52) 1250 3800 237.50
2 Mullion 1 13.7 3800 52.06
3 Transom 2 12.1 1250 30.25
4 Rook Wool 50 1250 1050 3.28
5 1.5mm Thk steel sheet 1250 1050 15.45
Back Pan
6 3mm Thk Alu sheet 1250 1050 10.63
7 Accessory 10% 34.92
Weight of 1 Panel 1234mmx3800mm 384.09
PRELIMINARY COMPUTATION DEAD LOAD OF PANEL

Page 33/40
DESCRIPTION OF STRUCTURAL CALCULATION

Code for reference/ Trích dẫn Tiêu chuẩn tham khảo

Page 34/40
DESCRIPTION OF STRUCTURAL CALCULATION

Page 35/40
DESCRIPTION OF STRUCTURAL CALCULATION

3. Annex 3: Load capacity analysis of cast-in channel at location 1 level 12 to level 18/ Phụ lục 3: Phân tích khả
năng chịu lực của cast-in channel vị trí 1 tầng 12 đến tầng 18

Page 36/40
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
Specifier's comments: LV 12-18, Load case: 1.4FSW+1.4(FWLP+FFL)
Annex 3.1

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4, longitudinal shear as per Hilti method
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = 180 mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: 0 mm

2 Overall Result
Design ok! (Maximum utilization: 62%)

IMPORTANT! Failure analysis modes evaluated by PROFIS follow EOTA TR 047/EN 1992-4. This DOES NOT include
evaluating the base material (e.g. edge-of-slab) capacity to resist compressive forces generated by the fixture.  The engineer
must ALWAYS verify the base material (e.g. edge-of-slab) design is capable of resisting the applied loading.
Compressive forces generated by the fixture = 16.666 kN

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm
Standoff: No standoff
Plate dimensions: 250 mm x 243 mm x 10 mm
1.1 1.2
Anchorplate design calculated: no Tension
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 5.473 3.286 1.177 3.068
1.2 5.816 8.632 1.177 8.552

max. concrete compressive strain: 0.10 [‰] Compression


max. concrete compressive stress: 3.4 [N/mm2]
resulting tension force in (x/y)=(127.6/203.0): 11.289 [kN]
resulting compression force in (x/y)=(118.3/97.3): 16.666 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.230 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] Vy [kN]
a1 5.576 4.718
a2 5.713 6.902

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
Anchor longitudinal shear forces [kN]
Anchor Vx
a1 1.177
a2 1.177

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 5.713 18.389 32 ok
Connection anchor-channel 5.713 13.889 42 ok
Channel lip 5.816 13.889 42 ok
Channel bolt 5.816 83.733 7 ok
Flexure channel 0.230 0.852 28 ok
Pull-out 5.713 31.350 19 ok
Concrete cone 5.713 16.442 35 ok
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

5.1.1 Steel failure (EN 1992-4 section 7.4.1.3)


5.1.1.1 Anchor (Anchor a2, Channel a)
NRk,s,a
NaEd ≤ NRd,s,a =
gMs

NaEd [kN] NRk,s,a [kN] gMs NRd,s,a [kN]


5.713 33.100 1.800 18.389

5.1.1.2 Connection between anchor and channel (Anchor a2, Channel a)


NRk,s,c
NaEd ≤ NRd,s,c =
gMs,ca

NaEd [kN] NRk,s,c [kN] gMs,ca NRd,s,c [kN]


5.713 25.000 1.800 13.889

5.1.1.3 Local flexure of channel lip (Fixture 1, Channel bolt 1.2, Channel a)
NRk,s,l
Ncb
Ed ≤ NRd,s,l =
gMs,l
NRk,s,l = N0Rk,s,l · y l,N

y l,N = 0.5 · 1 + ( scbo


sl,N )
≤ 1.0

scbo [mm] sl,N [mm] y l,N


170 82 1.000
Ncb
Ed [kN] N0Rk,s,l [kN] NRk,s,l [kN] gMs,l NRd,s,l [kN]
5.816 25.000 25.000 1.800 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.1.1.4 Channel bolt (Fixture 1, Channel bolt 1.2, Channel a)
NRk,s
Ncb
Ed ≤ NRd,s =
gMs

Ncb
Ed [kN] NRk,s [kN] gMs NRd,s [kN]
5.816 125.600 1.500 83.733

5.1.1.5 Flexure of channel (Channel a)


MRk,s,flex
Mch
Ed ≤ MRd,s,flex =
gMs,flex

Mch
Ed [kNm] MRk,s,flex [kNm] gMs,flex MRd,s,flex [kNm]
0.230 0.980 1.150 0.852

5.1.2 Pull-out failure (Anchor a2, Channel a) (EN 1992-4 section 7.4.1.4)
NRk,p
NaEd ≤ NRd,p =
gMp
NRk,p = k2 · Ah · fck

Ah [mm2]
209
NaEd [kN] k2 fck [N/mm2] NRk,p [kN] gMp NRd,p [kN]
5.713 7.5 30.0 47.025 1.500 31.350

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.1.3 Concrete cone (Anchor a2, Channel a) (EN 1992-4 section 7.4.1.5)
NRk,c
NaEd ≤ NRd,c =
gMc
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,N N0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5 · hef

0.5
y ch,c,N,1 = (cc ) 2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc ) 2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.827 120 195 0.784
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
NaEd [kN] NRk,c [kN] gMc NRd,c [kN]
5.713 24.663 1.500 16.442

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 8.632 50.240 18 ok
Flexure channel lip w/o lever arm - 8.552 13.889 62 ok
perpendicular
Flexure channel lip w/o lever arm - 1.177 7.817 16 ok
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 6.902 13.889 50 ok
Anchor - longitudinal 1.177 12.267 10 ok
Connection anchor/channel - 6.902 13.889 50 ok
perpendicular
Connection anchor/channel - 1.177 6.944 17 ok
longitudinal
Concrete pryout, perpendicular 6.902 34.687 20 ok
Concrete pryout, longitudinal 1.177 32.744 4 ok
Concrete edge - perpendicular N/A N/A N/A N/A
Concrete edge - longitudinal 2.354 50.562 5 ok
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
8.632 8.552 1.177 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y )
≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


170 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
8.552 34.900 34.900 1.800 19.389 13.889

5.2.1.3 Local flexure of channel lip - shear longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (Hilti method
based on CEN/TR 17080 section 7.3.3.1)

VRk,s,l,x
Vcb
Ed,x ≤ VRd,s,l,x =
gMs,l,x
VRk,s,l,x = V0Rk,s,l,x · y l,V
y l,V = 1.0
gMs,l,x = ginst · gMs,l

Vcb
Ed,x [kN] V0Rk,s,l,x [kN] VRk,s,l,x [kN] gMs,l ginst gMs,l,x VRd,s,l,x [kN]
1.177 19.700 19.700 1.800 1.400 2.520 7.817

5.2.1.4 Anchor - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


6.902 39.600 1.500 26.400 13.889

5.2.1.5 Anchor - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080 section 7.2.2.2.2)
VRk,s,a,x
VaEd,x ≤ VRd,s,a,x =
gMs

VaEd,x [kN] VRk,s,a,x [kN] gMs VRd,s,a,x [kN]


1.177 18.400 1.500 12.267

5.2.1.6 Connection between anchor and channel - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


6.902 39.600 1.800 22.000 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.1.7 Connection between anchor and channel - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR
17080 section 7.2.2.2.3)

VRk,s,c,x
VaEd,x ≤ VRd,s,c,x =
gMs,ca

VaEd,x [kN] VRk,s,c,x [kN] gMs,ca VRd,s,c,x [kN]


1.177 12.500 1.800 6.944

5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.872 120 195 0.784
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
6.902 2.0 26.015 52.030 1.500 34.687

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.3 Concrete pry-out failure - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080
section 7.2.2.3)

VRk,cp,x
VaEd,x ≤ VRd,cp,x =
gMc
VRk,cp,x = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.823 - 195 1.000
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- 120 1.000 0.784 1.000
VaEd,x [kN] k8 NRk,c [kN] VRk,cp,x [kN] gMc VRd,cp,x [kN]
1.177 2.0 24.558 49.117 1.500 32.744

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.4 Concrete edge failure - shear longitudinal, direction y- (Anchor a1, Channel a) (Hilti method based on EN 1992-4
section 7.2.2.5, CEN/TR 17080 section 7.2.2.4)

VRk,c,x
VaEd,x ≤ VRd,c,x =
gMc
Ac,V
VRk,c,x = V0Rk,c · · y s,V · y h,V · y re,V
A0c,V

V0Rk,c = k9 · danom · lbf · √fck · c1.5


1

0.5
a = 0.1 (cl )f
1

0.2
b = 0.1 (dc )nom
1

c2
y s,V = 0.7 + 0.3 ≤ 1.0
1.5 · c1
0.5
y h,V = (1.5h· c ) 1
≥ 1.0

k9 dnom [mm] l f [mm] a b fck [N/mm2] c1 [mm]


1.7 7 86 0.085 0.057 30.0 120
V0Rk,c [kN] Ac,V [mm2] A0c,V [mm2] c2 [mm] y s,V
18.650 109800 64800 - 1.000
h [mm] y h,V y a,V y re,V
180 1.000 2.000 1.200
VaEd,x [kN] VRk,c,x [kN] gMc VRd,c,x [kN]
2.354 75.844 1.500 50.562

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Channel bolt (Fixture 1, Channel bolt 1.2)
2 2

(NN ) + (√V V + V ) ≤ 1.000


cb cb 2 cb 2
Ed Ed,y Ed,x
bN+V,s =
Rd,s,cb Rd,s,cb

2
=( ) = 0.00482
cb
N Ed
bN,s
N Rd,s,cb

2
=( ) = 0.02952
√V cb 2
+V
Ed,y
cb 2
Ed,x
bV,s
V Rd,s,cb

bN+V,s = (0.00482) + (0.02952) = 0.03435 ≤ 1.000


(Utilization : 4%)

5.3.2 Point of load application - channel lip (Fixture 1, Channel bolt 1.2)
k71 k71 2

(NN ; MM ) + (VV ) + (VV ) ≤ 1.0


cb ch cb cb
Ed Ed Ed,y Ed,x
bN+V,la,c = max
Rd,s,l Rd,s,flex Rd,s,l,y Rd,s,l,x

2.0
= max ( ) = 0.17535
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

2.0
=( ) = 0.37912
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.02267
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.17535 + 0.37912 + 0.02267 ≤ 1.0


(Utilization : 58%)

bN,la,c, governing failure mode: Channel lip


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: Flexure channel lip w/o lever arm - longitudinal

5.3.3 Anchor and connection between anchor and channel (Anchor a2)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
2.0
= max( )
a
N Ed NaEd
bN,ac , = 0.16919
N Rd,s,a NRd,s,c
2.0
= max( ) = 0.24694
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.02873
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.16919 + 0.24694 + 0.02873 ≤ 1.0

(Utilization : 45%)

bN,ac, governing failure mode: Connection anchor-channel


bV,ac,y, governing failure mode: Anchor - perpendicular
bV,ac,x, governing failure mode: Connection anchor/channel - longitudinal

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3.4 Concrete anchor (Anchor a2)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.20481
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.08876
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.01005
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.20481 + 0.08876 + 0.01005 = 0.30361 ≤ 1.0


(Utilization : 31%)

bN,c, governing failure mode: Concrete cone


bV,c,y, governing failure mode: Concrete pryout, perpendicular
bV,c,x, governing failure mode: Concrete edge - longitudinal

Remarks and warnings


• Results for longitudinal shear are calculated according to CEN/TR 17080 (Design of fastenings for use in concrete - Anchor
channels - Supplementary rules), EN 1992-4 (Eurocode 2: Design of concrete structures - Part 4: Design of fastenings for
use in concrete)
• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The anchor plate overlaps the concrete base plate edges. A local concrete spalling due to compression close to the edges
has to be checked separately!
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 62%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 16
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 250 mm x 243 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

125 125

40
1.1 1.2

122
x
203
117

122

40 170 40

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 17
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
Specifier's comments: LV 12-18, Load case: 1.4FSW+1.4(FWLS+FFL)
Annex 3.2

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4, longitudinal shear as per Hilti method
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = 180 mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: -25 mm

2 Overall Result
Design ok! (Maximum utilization: 90%)

IMPORTANT! Failure analysis modes evaluated by PROFIS follow EOTA TR 047/EN 1992-4. This DOES NOT include
evaluating the base material (e.g. edge-of-slab) capacity to resist compressive forces generated by the fixture.  The engineer
must ALWAYS verify the base material (e.g. edge-of-slab) design is capable of resisting the applied loading.
Compressive forces generated by the fixture = 5.377 kN

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm
Standoff: No standoff
Plate dimensions: 250 mm x 243 mm x 10 mm
1.1 1.2
Anchorplate design calculated: no Compression
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 0.000 11.533 1.177 -11.473
1.2 0.000 6.104 1.177 -5.990

max. concrete compressive strain: 0.01 [‰]


max. concrete compressive stress: 0.5 [N/mm2]
resulting tension force in (x/y)=(0/0): 0.000 [kN]
resulting compression force in (x/y)=(98.7/199.9): 5.377 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.000 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] Vy [kN]
a1 0.000 -10.846
a2 0.000 -6.617

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
Anchor longitudinal shear forces [kN]
Anchor Vx
a1 1.177
a2 1.177

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor N/A N/A N/A N/A
Connection anchor-channel N/A N/A N/A N/A
Channel lip N/A N/A N/A N/A
Channel bolt N/A N/A N/A N/A
Flexure channel N/A N/A N/A N/A
Pull-out N/A N/A N/A N/A
Concrete cone N/A N/A N/A N/A
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 11.533 50.240 23 ok
Flexure channel lip w/o lever arm - 11.473 19.389 60 ok
perpendicular
Flexure channel lip w/o lever arm - 1.177 7.817 16 ok
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 10.846 26.400 42 ok
Anchor - longitudinal 1.177 12.267 10 ok
Connection anchor/channel - 10.846 22.000 50 ok
perpendicular
Connection anchor/channel - 1.177 6.944 17 ok
longitudinal
Concrete pryout, perpendicular 10.846 35.172 31 ok
Concrete pryout, longitudinal 1.177 32.744 4 ok
Concrete edge - perpendicular 10.846 12.113 90 ok
Concrete edge - longitudinal 2.354 50.562 5 ok
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
11.533 11.473 1.177 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y )
≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


170 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
11.473 34.900 34.900 1.800 19.389 19.389

5.2.1.3 Local flexure of channel lip - shear longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (Hilti method
based on CEN/TR 17080 section 7.3.3.1)

VRk,s,l,x
Vcb
Ed,x ≤ VRd,s,l,x =
gMs,l,x
VRk,s,l,x = V0Rk,s,l,x · y l,V
y l,V = 1.0
gMs,l,x = ginst · gMs,l

Vcb
Ed,x [kN] V0Rk,s,l,x [kN] VRk,s,l,x [kN] gMs,l ginst gMs,l,x VRd,s,l,x [kN]
1.177 19.700 19.700 1.800 1.400 2.520 7.817

5.2.1.4 Anchor - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


10.846 39.600 1.500 26.400 26.400

5.2.1.5 Anchor - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080 section 7.2.2.2.2)
VRk,s,a,x
VaEd,x ≤ VRd,s,a,x =
gMs

VaEd,x [kN] VRk,s,a,x [kN] gMs VRd,s,a,x [kN]


1.177 18.400 1.500 12.267

5.2.1.6 Connection between anchor and channel - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


10.846 39.600 1.800 22.000 22.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.1.7 Connection between anchor and channel - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR
17080 section 7.2.2.2.3)

VRk,s,c,x
VaEd,x ≤ VRd,s,c,x =
gMs,ca

VaEd,x [kN] VRk,s,c,x [kN] gMs,ca VRd,s,c,x [kN]


1.177 12.500 1.800 6.944

5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.884 120 195 0.784
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
10.846 2.0 26.379 52.757 1.500 35.172

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.3 Concrete pry-out failure - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080
section 7.2.2.3)

VRk,cp,x
VaEd,x ≤ VRd,cp,x =
gMc
VRk,cp,x = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.823 - 195 1.000
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- 120 1.000 0.784 1.000
VaEd,x [kN] k8 NRk,c [kN] VRk,cp,x [kN] gMc VRd,cp,x [kN]
1.177 2.0 24.558 49.117 1.500 32.744

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.4 Concrete edge failure - shear perpendicular, direction y- (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 120 24.314
s [mm] scr,V [mm] y ch,s,V
250 562 0.799
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
- - 281 1.000 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
180 296 0.780 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
10.846 18.169 1.500 12.113

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.5 Concrete edge failure - shear longitudinal, direction y- (Anchor a1, Channel a) (Hilti method based on EN 1992-4
section 7.2.2.5, CEN/TR 17080 section 7.2.2.4)

VRk,c,x
VaEd,x ≤ VRd,c,x =
gMc
Ac,V
VRk,c,x = V0Rk,c · · y s,V · y h,V · y re,V
A0c,V

V0Rk,c = k9 · danom · lbf · √fck · c1.5


1

0.5
a = 0.1 (cl )f
1

0.2
b = 0.1 (dc )nom
1

c2
y s,V = 0.7 + 0.3 ≤ 1.0
1.5 · c1
0.5
y h,V = (1.5h· c ) 1
≥ 1.0

k9 dnom [mm] l f [mm] a b fck [N/mm2] c1 [mm]


1.7 7 86 0.085 0.057 30.0 120
V0Rk,c [kN] Ac,V [mm2] A0c,V [mm2] c2 [mm] y s,V
18.650 109800 64800 - 1.000
h [mm] y h,V y a,V y re,V
180 1.000 2.000 1.200
VaEd,x [kN] VRk,c,x [kN] gMc VRd,c,x [kN]
2.354 75.844 1.500 50.562

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Point of load application - channel lip (Fixture 1, Channel bolt 1.1)
k71 k71 2
bN+V,la,c = max ( Ncb
Ed
; ) ( ) (
Mch
Ed
NRd,s,l MRd,s,flex
+
Vcb
Ed,y
VRd,s,l,y
+
Vcb
Ed,x
VRd,s,l,x ) ≤ 1.0
1.0
= max ( ) = 0.00000
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

1.0
=( ) = 0.59174
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.02267
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.00000 + 0.59174 + 0.02267 ≤ 1.0


(Utilization : 62%)

bN,la,c, governing failure mode: N/A


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: Flexure channel lip w/o lever arm - longitudinal

5.3.2 Anchor and connection between anchor and channel (Anchor a1)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
1.0
= max( )
a
N Ed NaEd
bN,ac , = 0.00000
N Rd,s,a NRd,s,c
1.0
= max( ) = 0.49300
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.02873
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.00000 + 0.49300 + 0.02873 ≤ 1.0

(Utilization : 53%)

bN,ac, governing failure mode: N/A


bV,ac,y, governing failure mode: Connection anchor/channel - perpendicular
bV,ac,x, governing failure mode: Connection anchor/channel - longitudinal

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.3.3 Concrete anchor (Anchor a1)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.00000
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.84727
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.01005
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.00000 + 0.84727 + 0.01005 = 0.85732 ≤ 1.0


(Utilization : 86%)

bN,c, governing failure mode: N/A


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: Concrete edge - longitudinal

Remarks and warnings


• Results for longitudinal shear are calculated according to CEN/TR 17080 (Design of fastenings for use in concrete - Anchor
channels - Supplementary rules), EN 1992-4 (Eurocode 2: Design of concrete structures - Part 4: Design of fastenings for
use in concrete)
• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The anchor plate overlaps the concrete base plate edges. A local concrete spalling due to compression close to the edges
has to be checked separately!
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 90%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 250 mm x 243 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

125 125

40
1.1 1.2

122
x
203
117

122

40 170 40

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 16
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
Specifier's comments: LV 12 18, Load case: 1.2FSW+1.2(FWLS+FFL)+1.2x0.8FSL
Annex 3.3

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4, longitudinal shear as per Hilti method
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = 180 mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: -25 mm

2 Overall Result
Design ok! (Maximum utilization: 82%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm
Standoff: No standoff
Plate dimensions: 250 mm x 243 mm x 10 mm
1.1
Compression 1.2
Anchorplate design calculated: no
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 0.000 10.326 1.009 -10.277
1.2 0.000 5.667 1.009 -5.576

max. concrete compressive strain: 0.02 [‰]


max. concrete compressive stress: 0.5 [N/mm2]
resulting tension force in (x/y)=(0/0): 0.000 [kN]
resulting compression force in (x/y)=(98.7/211.4): 4.609 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.000 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] Vy [kN]
a1 0.000 -9.791
a2 0.000 -6.062

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
Anchor longitudinal shear forces [kN]
Anchor Vx
a1 1.009
a2 1.009

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor N/A N/A N/A N/A
Connection anchor-channel N/A N/A N/A N/A
Channel lip N/A N/A N/A N/A
Channel bolt N/A N/A N/A N/A
Flexure channel N/A N/A N/A N/A
Pull-out N/A N/A N/A N/A
Concrete cone N/A N/A N/A N/A
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 10.326 50.240 21 ok
Flexure channel lip w/o lever arm - 10.277 19.389 54 ok
perpendicular
Flexure channel lip w/o lever arm - 1.009 7.817 13 ok
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 9.791 26.400 38 ok
Anchor - longitudinal 1.009 12.267 9 ok
Connection anchor/channel - 9.791 22.000 45 ok
perpendicular
Connection anchor/channel - 1.009 6.944 15 ok
longitudinal
Concrete pryout, perpendicular 9.791 35.111 28 ok
Concrete pryout, longitudinal 1.009 32.744 4 ok
Concrete edge - perpendicular 9.791 12.077 82 ok
Concrete edge - longitudinal 2.018 50.562 4 ok
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
10.326 10.277 1.009 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y )
≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


170 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
10.277 34.900 34.900 1.800 19.389 19.389

5.2.1.3 Local flexure of channel lip - shear longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (Hilti method
based on CEN/TR 17080 section 7.3.3.1)

VRk,s,l,x
Vcb
Ed,x ≤ VRd,s,l,x =
gMs,l,x
VRk,s,l,x = V0Rk,s,l,x · y l,V
y l,V = 1.0
gMs,l,x = ginst · gMs,l

Vcb
Ed,x [kN] V0Rk,s,l,x [kN] VRk,s,l,x [kN] gMs,l ginst gMs,l,x VRd,s,l,x [kN]
1.009 19.700 19.700 1.800 1.400 2.520 7.817

5.2.1.4 Anchor - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


9.791 39.600 1.500 26.400 26.400

5.2.1.5 Anchor - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080 section 7.2.2.2.2)
VRk,s,a,x
VaEd,x ≤ VRd,s,a,x =
gMs

VaEd,x [kN] VRk,s,a,x [kN] gMs VRd,s,a,x [kN]


1.009 18.400 1.500 12.267

5.2.1.6 Connection between anchor and channel - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


9.791 39.600 1.800 22.000 22.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.1.7 Connection between anchor and channel - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR
17080 section 7.2.2.2.3)

VRk,s,c,x
VaEd,x ≤ VRd,s,c,x =
gMs,ca

VaEd,x [kN] VRk,s,c,x [kN] gMs,ca VRd,s,c,x [kN]


1.009 12.500 1.800 6.944

5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.882 120 195 0.784
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
9.791 2.0 26.333 52.666 1.500 35.111

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.3 Concrete pry-out failure - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080
section 7.2.2.3)

VRk,cp,x
VaEd,x ≤ VRd,cp,x =
gMc
VRk,cp,x = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.823 - 195 1.000
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- 120 1.000 0.784 1.000
VaEd,x [kN] k8 NRk,c [kN] VRk,cp,x [kN] gMc VRd,cp,x [kN]
1.009 2.0 24.558 49.117 1.500 32.744

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.4 Concrete edge failure - shear perpendicular, direction y- (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 120 24.314
s [mm] scr,V [mm] y ch,s,V
250 562 0.796
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
- - 281 1.000 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
180 296 0.780 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
9.791 18.115 1.500 12.077

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.5 Concrete edge failure - shear longitudinal, direction y- (Anchor a1, Channel a) (Hilti method based on EN 1992-4
section 7.2.2.5, CEN/TR 17080 section 7.2.2.4)

VRk,c,x
VaEd,x ≤ VRd,c,x =
gMc
Ac,V
VRk,c,x = V0Rk,c · · y s,V · y h,V · y re,V
A0c,V

V0Rk,c = k9 · danom · lbf · √fck · c1.5


1

0.5
a = 0.1 (cl )f
1

0.2
b = 0.1 (dc )nom
1

c2
y s,V = 0.7 + 0.3 ≤ 1.0
1.5 · c1
0.5
y h,V = (1.5h· c ) 1
≥ 1.0

k9 dnom [mm] l f [mm] a b fck [N/mm2] c1 [mm]


1.7 7 86 0.085 0.057 30.0 120
V0Rk,c [kN] Ac,V [mm2] A0c,V [mm2] c2 [mm] y s,V
18.650 109800 64800 - 1.000
h [mm] y h,V y a,V y re,V
180 1.000 2.000 1.200
VaEd,x [kN] VRk,c,x [kN] gMc VRd,c,x [kN]
2.018 75.844 1.500 50.562

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Point of load application - channel lip (Fixture 1, Channel bolt 1.1)
k71 k71 2
bN+V,la,c = max ( Ncb
Ed
; ) ( ) (
Mch
Ed
NRd,s,l MRd,s,flex
+
Vcb
Ed,y
VRd,s,l,y
+
Vcb
Ed,x
VRd,s,l,x ) ≤ 1.0
1.0
= max ( ) = 0.00000
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

1.0
=( ) = 0.53004
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.01666
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.00000 + 0.53004 + 0.01666 ≤ 1.0


(Utilization : 55%)

bN,la,c, governing failure mode: N/A


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: Flexure channel lip w/o lever arm - longitudinal

5.3.2 Anchor and connection between anchor and channel (Anchor a1)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
1.0
= max( )
a
N Ed NaEd
bN,ac , = 0.00000
N Rd,s,a NRd,s,c
1.0
= max( ) = 0.44504
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.02111
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.00000 + 0.44504 + 0.02111 ≤ 1.0

(Utilization : 47%)

bN,ac, governing failure mode: N/A


bV,ac,y, governing failure mode: Connection anchor/channel - perpendicular
bV,ac,x, governing failure mode: Connection anchor/channel - longitudinal

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3.3 Concrete anchor (Anchor a1)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.00000
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.72996
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.00797
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.00000 + 0.72996 + 0.00797 = 0.73794 ≤ 1.0


(Utilization : 74%)

bN,c, governing failure mode: N/A


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: Concrete edge - longitudinal

Remarks and warnings


• Results for longitudinal shear are calculated according to CEN/TR 17080 (Design of fastenings for use in concrete - Anchor
channels - Supplementary rules), EN 1992-4 (Eurocode 2: Design of concrete structures - Part 4: Design of fastenings for
use in concrete)
• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The anchor plate overlaps the concrete base plate edges. A local concrete spalling due to compression close to the edges
has to be checked separately!
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 82%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 250 mm x 243 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

125 125

40
1.1 1.2

122
x
203
117

122

40 170 40

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 16
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
DESCRIPTION OF STRUCTURAL CALCULATION

4. Annex 4: Load capacity analysis of cast-in channel at location 1 level 19 to level 25/ Phụ lục 4: Phân tích khả
năng chịu lực của cast-in channel vị trí 1 tầng 19 đến tầng 25

Page 37/40
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.4FSW+1.4(FWLP+FFL)
Annex 4.1

1 Input data
Channel type HAC-50 106/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 106 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 42 mm, height: hch = 31 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4, longitudinal shear as per Hilti method
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = 180 mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: 0 mm

2 Overall Result
Design ok! (Maximum utilization: 46%)

IMPORTANT! Failure analysis modes evaluated by PROFIS follow EOTA TR 047/EN 1992-4. This DOES NOT include
evaluating the base material (e.g. edge-of-slab) capacity to resist compressive forces generated by the fixture.  The engineer
must ALWAYS verify the base material (e.g. edge-of-slab) design is capable of resisting the applied loading.
Compressive forces generated by the fixture = 16.957 kN

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm
Standoff: No standoff
Plate dimensions: 250 mm x 243 mm x 10 mm
1.1 1.2
Anchorplate design calculated: no Tension
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 5.611 3.434 1.231 3.206
1.2 5.970 9.023 1.231 8.939

max. concrete compressive strain: 0.10 [‰] Compression


max. concrete compressive stress: 3.4 [N/mm2]
resulting tension force in (x/y)=(127.6/203.0): 11.580 [kN]
resulting compression force in (x/y)=(118.1/97.2): 16.957 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 346 [mm] ≥ s
Iy = 33125 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.236 [kNm]

hef = 106

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] Vy [kN]
a1 5.721 4.969
a2 5.859 7.176

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
Anchor longitudinal shear forces [kN]
Anchor Vx
a1 1.231
a2 1.231

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 5.859 29.167 21 ok
Connection anchor-channel 5.859 19.444 31 ok
Channel lip 5.970 19.444 31 ok
Channel bolt 5.970 83.733 8 ok
Flexure channel 0.236 1.170 21 ok
Pull-out 5.859 38.700 16 ok
Concrete cone 5.859 19.252 31 ok
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

5.1.1 Steel failure (EN 1992-4 section 7.4.1.3)


5.1.1.1 Anchor (Anchor a2, Channel a)
NRk,s,a
NaEd ≤ NRd,s,a =
gMs

NaEd [kN] NRk,s,a [kN] gMs NRd,s,a [kN]


5.859 52.500 1.800 29.167

5.1.1.2 Connection between anchor and channel (Anchor a2, Channel a)


NRk,s,c
NaEd ≤ NRd,s,c =
gMs,ca

NaEd [kN] NRk,s,c [kN] gMs,ca NRd,s,c [kN]


5.859 35.000 1.800 19.444

5.1.1.3 Local flexure of channel lip (Fixture 1, Channel bolt 1.2, Channel a)
NRk,s,l
Ncb
Ed ≤ NRd,s,l =
gMs,l
NRk,s,l = N0Rk,s,l · y l,N

y l,N = 0.5 · 1 + ( scbo


sl,N )
≤ 1.0

scbo [mm] sl,N [mm] y l,N


170 84 1.000
Ncb
Ed [kN] N0Rk,s,l [kN] NRk,s,l [kN] gMs,l NRd,s,l [kN]
5.970 35.000 35.000 1.800 19.444

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.1.1.4 Channel bolt (Fixture 1, Channel bolt 1.2, Channel a)
NRk,s
Ncb
Ed ≤ NRd,s =
gMs

Ncb
Ed [kN] NRk,s [kN] gMs NRd,s [kN]
5.970 125.600 1.500 83.733

5.1.1.5 Flexure of channel (Channel a)


MRk,s,flex
Mch
Ed ≤ MRd,s,flex =
gMs,flex

Mch
Ed [kNm] MRk,s,flex [kNm] gMs,flex MRd,s,flex [kNm]
0.236 1.345 1.150 1.170

5.1.2 Pull-out failure (Anchor a2, Channel a) (EN 1992-4 section 7.4.1.4)
NRk,p
NaEd ≤ NRd,p =
gMp
NRk,p = k2 · Ah · fck

Ah [mm2]
258
NaEd [kN] k2 fck [N/mm2] NRk,p [kN] gMp NRd,p [kN]
5.859 7.5 30.0 58.050 1.500 38.700

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.1.3 Concrete cone (Anchor a2, Channel a) (EN 1992-4 section 7.4.1.5)
NRk,c
NaEd ≤ NRd,c =
gMc
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,N N0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5 · hef

0.5
y ch,c,N,1 = (cc ) 2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc ) 2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.2 30.0 106 49.015
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 431 0.790 120 216 0.746
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
NaEd [kN] NRk,c [kN] gMc NRd,c [kN]
5.859 28.879 1.500 19.252

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 9.023 50.240 18 ok
Flexure channel lip w/o lever arm - 8.939 19.444 46 ok
perpendicular
Flexure channel lip w/o lever arm - 1.231 7.817 16 ok
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 7.176 19.444 37 ok
Anchor - longitudinal 1.231 19.333 7 ok
Connection anchor/channel - 7.176 19.444 37 ok
perpendicular
Connection anchor/channel - 1.231 9.722 13 ok
longitudinal
Concrete pryout, perpendicular 7.176 41.011 18 ok
Concrete pryout, longitudinal 1.231 38.310 4 ok
Concrete edge - perpendicular N/A N/A N/A N/A
Concrete edge - longitudinal 2.461 53.886 5 ok
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
9.023 8.939 1.231 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y )
≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


170 84 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
8.939 47.500 47.500 1.800 26.389 19.444

5.2.1.3 Local flexure of channel lip - shear longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (Hilti method
based on CEN/TR 17080 section 7.3.3.1)

VRk,s,l,x
Vcb
Ed,x ≤ VRd,s,l,x =
gMs,l,x
VRk,s,l,x = V0Rk,s,l,x · y l,V
y l,V = 1.0
gMs,l,x = ginst · gMs,l

Vcb
Ed,x [kN] V0Rk,s,l,x [kN] VRk,s,l,x [kN] gMs,l ginst gMs,l,x VRd,s,l,x [kN]
1.231 19.700 19.700 1.800 1.400 2.520 7.817

5.2.1.4 Anchor - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


7.176 53.600 1.500 35.733 19.444

5.2.1.5 Anchor - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080 section 7.2.2.2.2)
VRk,s,a,x
VaEd,x ≤ VRd,s,a,x =
gMs

VaEd,x [kN] VRk,s,a,x [kN] gMs VRd,s,a,x [kN]


1.231 29.000 1.500 19.333

5.2.1.6 Connection between anchor and channel - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


7.176 53.600 1.800 29.778 19.444

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.1.7 Connection between anchor and channel - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR
17080 section 7.2.2.2.3)

VRk,s,c,x
VaEd,x ≤ VRd,s,c,x =
gMs,ca

VaEd,x [kN] VRk,s,c,x [kN] gMs,ca VRd,s,c,x [kN]


1.231 17.500 1.800 9.722

5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.2 30.0 106 49.015
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 431 0.841 120 216 0.746
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
7.176 2.0 30.758 61.516 1.500 41.011

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.3 Concrete pry-out failure - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080
section 7.2.2.3)

VRk,cp,x
VaEd,x ≤ VRd,cp,x =
gMc
VRk,cp,x = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.2 30.0 106 49.015
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 431 0.786 - 216 1.000
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- 120 1.000 0.746 1.000
VaEd,x [kN] k8 NRk,c [kN] VRk,cp,x [kN] gMc VRd,cp,x [kN]
1.231 2.0 28.733 57.465 1.500 38.310

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.4 Concrete edge failure - shear longitudinal, direction y- (Anchor a1, Channel a) (Hilti method based on EN 1992-4
section 7.2.2.5, CEN/TR 17080 section 7.2.2.4)

VRk,c,x
VaEd,x ≤ VRd,c,x =
gMc
Ac,V
VRk,c,x = V0Rk,c · · y s,V · y h,V · y re,V
A0c,V

V0Rk,c = k9 · danom · lbf · √fck · c1.5


1

0.5
a = 0.1 (cl )f
1

0.2
b = 0.1 (dc )nom
1

c2
y s,V = 0.7 + 0.3 ≤ 1.0
1.5 · c1
0.5
y h,V = (1.5h· c ) 1
≥ 1.0

k9 dnom [mm] l f [mm] a b fck [N/mm2] c1 [mm]


1.7 9 106 0.094 0.060 30.0 120
V0Rk,c [kN] Ac,V [mm2] A0c,V [mm2] c2 [mm] y s,V
19.876 109800 64800 - 1.000
h [mm] y h,V y a,V y re,V
180 1.000 2.000 1.200
VaEd,x [kN] VRk,c,x [kN] gMc VRd,c,x [kN]
2.461 80.829 1.500 53.886

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Channel bolt (Fixture 1, Channel bolt 1.2)
2 2

(NN ) + (√V V + V ) ≤ 1.000


cb cb 2 cb 2
Ed Ed,y Ed,x
bN+V,s =
Rd,s,cb Rd,s,cb

2
=( ) = 0.00508
cb
N Ed
bN,s
N Rd,s,cb

2
=( ) = 0.03226
√V cb 2
+V
Ed,y
cb 2
Ed,x
bV,s
V Rd,s,cb

bN+V,s = (0.00508) + (0.03226) = 0.03734 ≤ 1.000


(Utilization : 4%)

5.3.2 Point of load application - channel lip (Fixture 1, Channel bolt 1.2)
k71 k71 2

(NN ; MM ) + (VV ) + (VV ) ≤ 1.0


cb ch cb cb
Ed Ed Ed,y Ed,x
bN+V,la,c = max
Rd,s,l Rd,s,flex Rd,s,l,y Rd,s,l,x

2.0
= max ( ) = 0.09426
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

2.0
=( ) = 0.21133
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.02478
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.09426 + 0.21133 + 0.02478 ≤ 1.0


(Utilization : 34%)

bN,la,c, governing failure mode: Channel lip


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: Flexure channel lip w/o lever arm - longitudinal

5.3.3 Anchor and connection between anchor and channel (Anchor a2)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
2.0
= max( )
a
N Ed NaEd
bN,ac , = 0.09080
N Rd,s,a NRd,s,c
2.0
= max( ) = 0.13618
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.01602
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.09080 + 0.13618 + 0.01602 ≤ 1.0

(Utilization : 25%)

bN,ac, governing failure mode: Connection anchor-channel


bV,ac,y, governing failure mode: Anchor - perpendicular
bV,ac,x, governing failure mode: Connection anchor/channel - longitudinal

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3.4 Concrete anchor (Anchor a2)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.16789
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.07319
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.00976
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.16789 + 0.07319 + 0.00976 = 0.25084 ≤ 1.0


(Utilization : 26%)

bN,c, governing failure mode: Concrete cone


bV,c,y, governing failure mode: Concrete pryout, perpendicular
bV,c,x, governing failure mode: Concrete edge - longitudinal

Remarks and warnings


• Results for longitudinal shear are calculated according to CEN/TR 17080 (Design of fastenings for use in concrete - Anchor
channels - Supplementary rules), EN 1992-4 (Eurocode 2: Design of concrete structures - Part 4: Design of fastenings for
use in concrete)
• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The anchor plate overlaps the concrete base plate edges. A local concrete spalling due to compression close to the edges
has to be checked separately!
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 46%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 16
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 250 mm x 243 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

125 125

40
1.1 1.2

122
x
203
117

122

40 170 40

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 17
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.4FSW+1.4(FWLS+FFL)
Annex 4.2

1 Input data
Channel type HAC-50 106/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 106 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 42 mm, height: hch = 31 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4, longitudinal shear as per Hilti method
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = 180 mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: -25 mm

2 Overall Result
Design ok! (Maximum utilization: 95%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm
Standoff: No standoff
Plate dimensions: 250 mm x 243 mm x 10 mm
1.1
Compression 1.2
Anchorplate design calculated: no
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 0.000 12.054 1.231 -11.991
1.2 0.000 6.378 1.231 -6.259

max. concrete compressive strain: 0.02 [‰]


max. concrete compressive stress: 0.6 [N/mm2]
resulting tension force in (x/y)=(0/0): 0.000 [kN]
resulting compression force in (x/y)=(97.5/208.6): 5.377 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 346 [mm] ≥ s
Iy = 33125 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.000 [kNm]

hef = 106

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] Vy [kN]
a1 0.000 -11.261
a2 0.000 -6.989

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
Anchor longitudinal shear forces [kN]
Anchor Vx
a1 1.231
a2 1.231

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor N/A N/A N/A N/A
Connection anchor-channel N/A N/A N/A N/A
Channel lip N/A N/A N/A N/A
Channel bolt N/A N/A N/A N/A
Flexure channel N/A N/A N/A N/A
Pull-out N/A N/A N/A N/A
Concrete cone N/A N/A N/A N/A
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 12.054 50.240 24 ok
Flexure channel lip w/o lever arm - 11.991 26.389 46 ok
perpendicular
Flexure channel lip w/o lever arm - 1.231 7.817 16 ok
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 11.261 35.733 32 ok
Anchor - longitudinal 1.231 19.333 7 ok
Connection anchor/channel - 11.261 29.778 38 ok
perpendicular
Connection anchor/channel - 1.231 9.722 13 ok
longitudinal
Concrete pryout, perpendicular 11.261 41.698 28 ok
Concrete pryout, longitudinal 1.231 38.310 4 ok
Concrete edge - perpendicular 11.261 11.940 95 ok
Concrete edge - longitudinal 2.461 53.886 5 ok
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
12.054 11.991 1.231 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y )
≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


170 84 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
11.991 47.500 47.500 1.800 26.389 26.389

5.2.1.3 Local flexure of channel lip - shear longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (Hilti method
based on CEN/TR 17080 section 7.3.3.1)

VRk,s,l,x
Vcb
Ed,x ≤ VRd,s,l,x =
gMs,l,x
VRk,s,l,x = V0Rk,s,l,x · y l,V
y l,V = 1.0
gMs,l,x = ginst · gMs,l

Vcb
Ed,x [kN] V0Rk,s,l,x [kN] VRk,s,l,x [kN] gMs,l ginst gMs,l,x VRd,s,l,x [kN]
1.231 19.700 19.700 1.800 1.400 2.520 7.817

5.2.1.4 Anchor - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


11.261 53.600 1.500 35.733 35.733

5.2.1.5 Anchor - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080 section 7.2.2.2.2)
VRk,s,a,x
VaEd,x ≤ VRd,s,a,x =
gMs

VaEd,x [kN] VRk,s,a,x [kN] gMs VRd,s,a,x [kN]


1.231 29.000 1.500 19.333

5.2.1.6 Connection between anchor and channel - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


11.261 53.600 1.800 29.778 29.778

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.1.7 Connection between anchor and channel - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR
17080 section 7.2.2.2.3)

VRk,s,c,x
VaEd,x ≤ VRd,s,c,x =
gMs,ca

VaEd,x [kN] VRk,s,c,x [kN] gMs,ca VRd,s,c,x [kN]


1.231 17.500 1.800 9.722

5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.2 30.0 106 49.015
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 431 0.855 120 216 0.746
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
11.261 2.0 31.273 62.547 1.500 41.698

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.3 Concrete pry-out failure - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080
section 7.2.2.3)

VRk,cp,x
VaEd,x ≤ VRd,cp,x =
gMc
VRk,cp,x = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.2 30.0 106 49.015
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 431 0.786 - 216 1.000
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- 120 1.000 0.746 1.000
VaEd,x [kN] k8 NRk,c [kN] VRk,cp,x [kN] gMc VRd,cp,x [kN]
1.231 2.0 28.733 57.465 1.500 38.310

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.4 Concrete edge failure - shear perpendicular, direction y- (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 120 24.314
s [mm] scr,V [mm] y ch,s,V
250 564 0.795
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
- - 282 1.000 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
180 302 0.772 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
11.261 17.910 1.500 11.940

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.5 Concrete edge failure - shear longitudinal, direction y- (Anchor a1, Channel a) (Hilti method based on EN 1992-4
section 7.2.2.5, CEN/TR 17080 section 7.2.2.4)

VRk,c,x
VaEd,x ≤ VRd,c,x =
gMc
Ac,V
VRk,c,x = V0Rk,c · · y s,V · y h,V · y re,V
A0c,V

V0Rk,c = k9 · danom · lbf · √fck · c1.5


1

0.5
a = 0.1 (cl )f
1

0.2
b = 0.1 (dc )nom
1

c2
y s,V = 0.7 + 0.3 ≤ 1.0
1.5 · c1
0.5
y h,V = (1.5h· c ) 1
≥ 1.0

k9 dnom [mm] l f [mm] a b fck [N/mm2] c1 [mm]


1.7 9 106 0.094 0.060 30.0 120
V0Rk,c [kN] Ac,V [mm2] A0c,V [mm2] c2 [mm] y s,V
19.876 109800 64800 - 1.000
h [mm] y h,V y a,V y re,V
180 1.000 2.000 1.200
VaEd,x [kN] VRk,c,x [kN] gMc VRd,c,x [kN]
2.461 80.829 1.500 53.886

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Point of load application - channel lip (Fixture 1, Channel bolt 1.1)
k71 k71 2
bN+V,la,c = max ( Ncb
Ed
; ) ( ) (
Mch
Ed
NRd,s,l MRd,s,flex
+
Vcb
Ed,y
VRd,s,l,y
+
Vcb
Ed,x
VRd,s,l,x ) ≤ 1.0
1.0
= max ( ) = 0.00000
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

1.0
=( ) = 0.45441
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.02478
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.00000 + 0.45441 + 0.02478 ≤ 1.0


(Utilization : 48%)

bN,la,c, governing failure mode: N/A


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: Flexure channel lip w/o lever arm - longitudinal

5.3.2 Anchor and connection between anchor and channel (Anchor a1)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
1.0
= max( )
a
N Ed NaEd
bN,ac , = 0.00000
N Rd,s,a NRd,s,c
1.0
= max( ) = 0.37816
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.01602
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.00000 + 0.37816 + 0.01602 ≤ 1.0

(Utilization : 40%)

bN,ac, governing failure mode: N/A


bV,ac,y, governing failure mode: Connection anchor/channel - perpendicular
bV,ac,x, governing failure mode: Connection anchor/channel - longitudinal

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.3.3 Concrete anchor (Anchor a1)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.00000
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.91591
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.00976
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.00000 + 0.91591 + 0.00976 = 0.92567 ≤ 1.0


(Utilization : 93%)

bN,c, governing failure mode: N/A


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: Concrete edge - longitudinal

Remarks and warnings


• Results for longitudinal shear are calculated according to CEN/TR 17080 (Design of fastenings for use in concrete - Anchor
channels - Supplementary rules), EN 1992-4 (Eurocode 2: Design of concrete structures - Part 4: Design of fastenings for
use in concrete)
• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The anchor plate overlaps the concrete base plate edges. A local concrete spalling due to compression close to the edges
has to be checked separately!
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 95%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 250 mm x 243 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

125 125

40
1.1 1.2

122
x
203
117

122

40 170 40

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 16
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.2FSW+1.2(FWLS+FFL)+1.2x0.8FSL
Annex 4.3

1 Input data
Channel type HAC-50 106/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 106 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 42 mm, height: hch = 31 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4, longitudinal shear as per Hilti method
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = 180 mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: -25 mm

2 Overall Result
Design ok! (Maximum utilization: 86%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm
Standoff: No standoff
Plate dimensions: 250 mm x 243 mm x 10 mm Compression
1.1 1.2
Anchorplate design calculated: no
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 0.000 10.772 1.055 -10.720
1.2 0.000 5.903 1.055 -5.808

max. concrete compressive strain: 0.02 [‰]


max. concrete compressive stress: 0.7 [N/mm2]
resulting tension force in (x/y)=(0/0): 0.000 [kN]
resulting compression force in (x/y)=(97.5/220.2): 4.609 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 346 [mm] ≥ s
Iy = 33125 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.000 [kNm]

hef = 106

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] Vy [kN]
a1 0.000 -10.145
a2 0.000 -6.383

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
Anchor longitudinal shear forces [kN]
Anchor Vx
a1 1.055
a2 1.055

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor N/A N/A N/A N/A
Connection anchor-channel N/A N/A N/A N/A
Channel lip N/A N/A N/A N/A
Channel bolt N/A N/A N/A N/A
Flexure channel N/A N/A N/A N/A
Pull-out N/A N/A N/A N/A
Concrete cone N/A N/A N/A N/A
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 10.772 50.240 22 ok
Flexure channel lip w/o lever arm - 10.720 26.389 41 ok
perpendicular
Flexure channel lip w/o lever arm - 1.055 7.817 14 ok
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 10.145 35.733 29 ok
Anchor - longitudinal 1.055 19.333 6 ok
Connection anchor/channel - 10.145 29.778 35 ok
perpendicular
Connection anchor/channel - 1.055 9.722 11 ok
longitudinal
Concrete pryout, perpendicular 10.145 41.615 25 ok
Concrete pryout, longitudinal 1.055 38.310 3 ok
Concrete edge - perpendicular 10.145 11.906 86 ok
Concrete edge - longitudinal 2.109 53.886 4 ok
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
10.772 10.720 1.055 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y )
≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


170 84 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
10.720 47.500 47.500 1.800 26.389 26.389

5.2.1.3 Local flexure of channel lip - shear longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (Hilti method
based on CEN/TR 17080 section 7.3.3.1)

VRk,s,l,x
Vcb
Ed,x ≤ VRd,s,l,x =
gMs,l,x
VRk,s,l,x = V0Rk,s,l,x · y l,V
y l,V = 1.0
gMs,l,x = ginst · gMs,l

Vcb
Ed,x [kN] V0Rk,s,l,x [kN] VRk,s,l,x [kN] gMs,l ginst gMs,l,x VRd,s,l,x [kN]
1.055 19.700 19.700 1.800 1.400 2.520 7.817

5.2.1.4 Anchor - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


10.145 53.600 1.500 35.733 35.733

5.2.1.5 Anchor - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080 section 7.2.2.2.2)
VRk,s,a,x
VaEd,x ≤ VRd,s,a,x =
gMs

VaEd,x [kN] VRk,s,a,x [kN] gMs VRd,s,a,x [kN]


1.055 29.000 1.500 19.333

5.2.1.6 Connection between anchor and channel - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


10.145 53.600 1.800 29.778 29.778

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.1.7 Connection between anchor and channel - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR
17080 section 7.2.2.2.3)

VRk,s,c,x
VaEd,x ≤ VRd,s,c,x =
gMs,ca

VaEd,x [kN] VRk,s,c,x [kN] gMs,ca VRd,s,c,x [kN]


1.055 17.500 1.800 9.722

5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.2 30.0 106 49.015
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 431 0.854 120 216 0.746
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
10.145 2.0 31.211 62.422 1.500 41.615

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.3 Concrete pry-out failure - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080
section 7.2.2.3)

VRk,cp,x
VaEd,x ≤ VRd,cp,x =
gMc
VRk,cp,x = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.2 30.0 106 49.015
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 431 0.786 - 216 1.000
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- 120 1.000 0.746 1.000
VaEd,x [kN] k8 NRk,c [kN] VRk,cp,x [kN] gMc VRd,cp,x [kN]
1.055 2.0 28.733 57.465 1.500 38.310

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.4 Concrete edge failure - shear perpendicular, direction y- (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 120 24.314
s [mm] scr,V [mm] y ch,s,V
250 564 0.793
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
- - 282 1.000 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
180 302 0.772 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
10.145 17.859 1.500 11.906

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.5 Concrete edge failure - shear longitudinal, direction y- (Anchor a1, Channel a) (Hilti method based on EN 1992-4
section 7.2.2.5, CEN/TR 17080 section 7.2.2.4)

VRk,c,x
VaEd,x ≤ VRd,c,x =
gMc
Ac,V
VRk,c,x = V0Rk,c · · y s,V · y h,V · y re,V
A0c,V

V0Rk,c = k9 · danom · lbf · √fck · c1.5


1

0.5
a = 0.1 (cl )f
1

0.2
b = 0.1 (dc )nom
1

c2
y s,V = 0.7 + 0.3 ≤ 1.0
1.5 · c1
0.5
y h,V = (1.5h· c ) 1
≥ 1.0

k9 dnom [mm] l f [mm] a b fck [N/mm2] c1 [mm]


1.7 9 106 0.094 0.060 30.0 120
V0Rk,c [kN] Ac,V [mm2] A0c,V [mm2] c2 [mm] y s,V
19.876 109800 64800 - 1.000
h [mm] y h,V y a,V y re,V
180 1.000 2.000 1.200
VaEd,x [kN] VRk,c,x [kN] gMc VRd,c,x [kN]
2.109 80.829 1.500 53.886

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Point of load application - channel lip (Fixture 1, Channel bolt 1.1)
k71 k71 2
bN+V,la,c = max ( Ncb
Ed
; ) ( ) (
Mch
Ed
NRd,s,l MRd,s,flex
+
Vcb
Ed,y
VRd,s,l,y
+
Vcb
Ed,x
VRd,s,l,x ) ≤ 1.0
1.0
= max ( ) = 0.00000
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

1.0
=( ) = 0.40625
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.01820
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.00000 + 0.40625 + 0.01820 ≤ 1.0


(Utilization : 43%)

bN,la,c, governing failure mode: N/A


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: Flexure channel lip w/o lever arm - longitudinal

5.3.2 Anchor and connection between anchor and channel (Anchor a1)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
1.0
= max( )
a
N Ed NaEd
bN,ac , = 0.00000
N Rd,s,a NRd,s,c
1.0
= max( ) = 0.34068
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.01176
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.00000 + 0.34068 + 0.01176 ≤ 1.0

(Utilization : 36%)

bN,ac, governing failure mode: N/A


bV,ac,y, governing failure mode: Connection anchor/channel - perpendicular
bV,ac,x, governing failure mode: Connection anchor/channel - longitudinal

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3.3 Concrete anchor (Anchor a1)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.00000
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.78649
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.00774
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.00000 + 0.78649 + 0.00774 = 0.79423 ≤ 1.0


(Utilization : 80%)

bN,c, governing failure mode: N/A


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: Concrete edge - longitudinal

Remarks and warnings


• Results for longitudinal shear are calculated according to CEN/TR 17080 (Design of fastenings for use in concrete - Anchor
channels - Supplementary rules), EN 1992-4 (Eurocode 2: Design of concrete structures - Part 4: Design of fastenings for
use in concrete)
• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The anchor plate overlaps the concrete base plate edges. A local concrete spalling due to compression close to the edges
has to be checked separately!
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 86%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 250 mm x 243 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 250 x 10 x 0 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

125 125

40
1.1 1.2

122
x
203
117

122

40 170 40

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 16
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 1
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
DESCRIPTION OF STRUCTURAL CALCULATION

5. Annex 5: Load capacity analysis of cast-in channel at location 2 level 12 to level 25/ Phụ lục 5: Phân tích khả
năng chịu lực của cast-in channel vị trí 2 tầng 12 đến tầng 25

Page 38/40
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.4FSW+1.4(FWLP+FFL)
Annex 5.1

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4, longitudinal shear as per Hilti method
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = ∞ mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: -25 mm

2 Overall Result
Design ok! (Maximum utilization: 22%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 150 x 20 x 10 mm
Standoff: No standoff
Plate dimensions: 300 mm x 150 mm x 10 mm
Anchorplate design calculated: no
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 0.000 2.957 1.231 -2.689
1.2 0.000 2.957 1.231 -2.689 1.1 1.2

max. concrete compressive strain: 0.02 [‰]


Compression
max. concrete compressive stress: 0.6 [N/mm2]
resulting tension force in (x/y)=(0/0): 0.000 [kN]
resulting compression force in (x/y)=(165.8/50.6): 11.712 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.000 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] Vy [kN]
a1 0.000 -3.003
a2 0.000 -2.374

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
Anchor longitudinal shear forces [kN]
Anchor Vx
a1 1.231
a2 1.231

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor N/A N/A N/A N/A
Connection anchor-channel N/A N/A N/A N/A
Channel lip N/A N/A N/A N/A
Channel bolt N/A N/A N/A N/A
Flexure channel N/A N/A N/A N/A
Pull-out N/A N/A N/A N/A
Concrete cone N/A N/A N/A N/A
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 2.957 50.240 6 ok
Flexure channel lip w/o lever arm - 2.689 19.389 14 ok
perpendicular
Flexure channel lip w/o lever arm - 1.231 7.817 16 ok
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 3.003 26.400 12 ok
Anchor - longitudinal 1.231 12.267 11 ok
Connection anchor/channel - 3.003 22.000 14 ok
perpendicular
Connection anchor/channel - 1.231 6.944 18 ok
longitudinal
Concrete pryout, perpendicular 3.003 33.290 10 ok
Concrete pryout, longitudinal 1.231 24.617 5 ok
Concrete edge - perpendicular 3.003 14.004 22 ok
Concrete edge - longitudinal 2.461 48.560 6 ok
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
2.957 2.689 1.231 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y )
≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


180 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
2.689 34.900 34.900 1.800 19.389 19.389

5.2.1.3 Local flexure of channel lip - shear longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (Hilti method
based on CEN/TR 17080 section 7.3.3.1)

VRk,s,l,x
Vcb
Ed,x ≤ VRd,s,l,x =
gMs,l,x
VRk,s,l,x = V0Rk,s,l,x · y l,V
y l,V = 1.0
gMs,l,x = ginst · gMs,l

Vcb
Ed,x [kN] V0Rk,s,l,x [kN] VRk,s,l,x [kN] gMs,l ginst gMs,l,x VRd,s,l,x [kN]
1.231 19.700 19.700 1.800 1.400 2.520 7.817

5.2.1.4 Anchor - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


3.003 39.600 1.500 26.400 26.400

5.2.1.5 Anchor - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080 section 7.2.2.2.2)
VRk,s,a,x
VaEd,x ≤ VRd,s,a,x =
gMs

VaEd,x [kN] VRk,s,a,x [kN] gMs VRd,s,a,x [kN]


1.231 18.400 1.500 12.267

5.2.1.6 Connection between anchor and channel - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


3.003 39.600 1.800 22.000 22.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.1.7 Connection between anchor and channel - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR
17080 section 7.2.2.2.3)

VRk,s,c,x
VaEd,x ≤ VRd,s,c,x =
gMs,ca

VaEd,x [kN] VRk,s,c,x [kN] gMs,ca VRd,s,c,x [kN]


1.231 12.500 1.800 6.944

5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.855 115 195 0.768
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
3.003 2.0 24.968 49.936 1.500 33.290

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.3 Concrete pry-out failure - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080
section 7.2.2.3)

VRk,cp,x
VaEd,x ≤ VRd,cp,x =
gMc
VRk,cp,x = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.823 - 195 1.000
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
115 115 0.768 0.768 1.000
VaEd,x [kN] k8 NRk,c [kN] VRk,cp,x [kN] gMc VRd,cp,x [kN]
1.231 2.0 18.463 36.925 1.500 24.617

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.4 Concrete edge failure - shear perpendicular, direction y- (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 115 22.973
s [mm] scr,V [mm] y ch,s,V
250 542 0.762
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
- - 271 1.000 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
10000 286 1.000 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
3.003 21.006 1.500 14.004

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.5 Concrete edge failure - shear longitudinal, direction y+ (Anchor a1, Channel a) (Hilti method based on EN 1992-4
section 7.2.2.5, CEN/TR 17080 section 7.2.2.4)

VRk,c,x
VaEd,x ≤ VRd,c,x =
gMc
Ac,V
VRk,c,x = V0Rk,c · · y s,V · y h,V · y re,V
A0c,V

V0Rk,c = k9 · danom · lbf · √fck · c1.5


1

0.5
a = 0.1 (cl )f
1

0.2
b = 0.1 (dc )nom
1

c2
y s,V = 0.7 + 0.3 ≤ 1.0
1.5 · c1
0.5
y h,V = (1.5h· c ) 1
≥ 1.0

k9 dnom [mm] l f [mm] a b fck [N/mm2] c1 [mm]


1.7 7 86 0.087 0.057 30.0 115
V0Rk,c [kN] Ac,V [mm2] A0c,V [mm2] c2 [mm] y s,V
17.598 102638 59513 - 1.000
h [mm] y h,V y a,V y re,V
10000 1.000 2.000 1.200
VaEd,x [kN] VRk,c,x [kN] gMc VRd,c,x [kN]
2.461 72.840 1.500 48.560

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Point of load application - channel lip (Fixture 1, Channel bolt 1.1)
k71 k71 2
bN+V,la,c = max ( Ncb
Ed
; ) ( ) (
Mch
Ed
NRd,s,l MRd,s,flex
+
Vcb
Ed,y
VRd,s,l,y
+
Vcb
Ed,x
VRd,s,l,x ) ≤ 1.0
1.0
= max ( ) = 0.00000
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

1.0
=( ) = 0.13866
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.02478
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.00000 + 0.13866 + 0.02478 ≤ 1.0


(Utilization : 17%)

bN,la,c, governing failure mode: N/A


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: Flexure channel lip w/o lever arm - longitudinal

5.3.2 Anchor and connection between anchor and channel (Anchor a1)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
1.0
= max( )
a
N Ed NaEd
bN,ac , = 0.00000
N Rd,s,a NRd,s,c
1.0
= max( ) = 0.13652
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.03140
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.00000 + 0.13652 + 0.03140 ≤ 1.0

(Utilization : 17%)

bN,ac, governing failure mode: N/A


bV,ac,y, governing failure mode: Connection anchor/channel - perpendicular
bV,ac,x, governing failure mode: Connection anchor/channel - longitudinal

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3.3 Concrete anchor (Anchor a1)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.00000
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.09932
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.01141
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.00000 + 0.09932 + 0.01141 = 0.11073 ≤ 1.0


(Utilization : 12%)

bN,c, governing failure mode: N/A


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: Concrete edge - longitudinal

Remarks and warnings


• Results for longitudinal shear are calculated according to CEN/TR 17080 (Design of fastenings for use in concrete - Anchor
channels - Supplementary rules), EN 1992-4 (Eurocode 2: Design of concrete structures - Part 4: Design of fastenings for
use in concrete)
• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 22%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 300 mm x 150 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 150 x 20 x 10 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

150 150

65

1.1 1.2 75
x
85

75

60 180 60

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 16
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.4FSW+1.4(FWLS+FFL)
Annex 5.2

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4, longitudinal shear as per Hilti method
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = ∞ mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: -25 mm

2 Overall Result
Design ok! (Maximum utilization: 98%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 150 x 20 x 10 mm
Standoff: No standoff
Plate dimensions: 300 mm x 150 mm x 10 mm
Anchorplate design calculated: no
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 12.021 2.957 1.231 -2.689
1.2 11.326 2.957 1.231 -2.689
1.1 1.2
Tension
max. concrete compressive strain: 0.10 [‰]
max. concrete compressive stress: 3.3 [N/mm2]
resulting tension force in (x/y)=(147.3/75.0): 23.346 [kN]
resulting compression force in (x/y)=(171.2/4.8): 5.746 [kN]
Compression
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.545 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] Vy [kN]
a1 13.187 -3.003
a2 10.159 -2.374

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
Anchor longitudinal shear forces [kN]
Anchor Vx
a1 1.231
a2 1.231

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 13.187 18.389 72 ok
Connection anchor-channel 13.187 13.889 95 ok
Channel lip 12.021 13.889 87 ok
Channel bolt 12.021 83.733 15 ok
Flexure channel 0.545 0.852 64 ok
Pull-out 13.187 31.350 43 ok
Concrete cone 13.187 16.706 79 ok
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

5.1.1 Steel failure (EN 1992-4 section 7.4.1.3)


5.1.1.1 Anchor (Anchor a1, Channel a)
NRk,s,a
NaEd ≤ NRd,s,a =
gMs

NaEd [kN] NRk,s,a [kN] gMs NRd,s,a [kN]


13.187 33.100 1.800 18.389

5.1.1.2 Connection between anchor and channel (Anchor a1, Channel a)


NRk,s,c
NaEd ≤ NRd,s,c =
gMs,ca

NaEd [kN] NRk,s,c [kN] gMs,ca NRd,s,c [kN]


13.187 25.000 1.800 13.889

5.1.1.3 Local flexure of channel lip (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s,l
Ncb
Ed ≤ NRd,s,l =
gMs,l
NRk,s,l = N0Rk,s,l · y l,N

y l,N = 0.5 · 1 + ( scbo


sl,N )
≤ 1.0

scbo [mm] sl,N [mm] y l,N


180 82 1.000
Ncb
Ed [kN] N0Rk,s,l [kN] NRk,s,l [kN] gMs,l NRd,s,l [kN]
12.021 25.000 25.000 1.800 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.1.1.4 Channel bolt (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s
Ncb
Ed ≤ NRd,s =
gMs

Ncb
Ed [kN] NRk,s [kN] gMs NRd,s [kN]
12.021 125.600 1.500 83.733

5.1.1.5 Flexure of channel (Channel a)


MRk,s,flex
Mch
Ed ≤ MRd,s,flex =
gMs,flex

Mch
Ed [kNm] MRk,s,flex [kNm] gMs,flex MRd,s,flex [kNm]
0.545 0.980 1.150 0.852

5.1.2 Pull-out failure (Anchor a1, Channel a) (EN 1992-4 section 7.4.1.4)
NRk,p
NaEd ≤ NRd,p =
gMp
NRk,p = k2 · Ah · fck

Ah [mm2]
209
NaEd [kN] k2 fck [N/mm2] NRk,p [kN] gMp NRd,p [kN]
13.187 7.5 30.0 47.025 1.500 31.350

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.1.3 Concrete cone (Anchor a1, Channel a) (EN 1992-4 section 7.4.1.5)
NRk,c
NaEd ≤ NRd,c =
gMc
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,N N0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5 · hef

0.5
y ch,c,N,1 = (cc ) 2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc ) 2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.858 115 195 0.768
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
NaEd [kN] NRk,c [kN] gMc NRd,c [kN]
13.187 25.059 1.500 16.706

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 2.957 50.240 6 ok
Flexure channel lip w/o lever arm - 2.689 13.889 20 ok
perpendicular
Flexure channel lip w/o lever arm - 1.231 7.817 16 ok
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 3.003 13.889 22 ok
Anchor - longitudinal 1.231 12.267 11 ok
Connection anchor/channel - 3.003 13.889 22 ok
perpendicular
Connection anchor/channel - 1.231 6.944 18 ok
longitudinal
Concrete pryout, perpendicular 3.003 33.290 10 ok
Concrete pryout, longitudinal 1.231 24.617 5 ok
Concrete edge - perpendicular 3.003 14.004 22 ok
Concrete edge - longitudinal 2.461 48.560 6 ok
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
2.957 2.689 1.231 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y )
≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


180 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
2.689 34.900 34.900 1.800 19.389 13.889

5.2.1.3 Local flexure of channel lip - shear longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (Hilti method
based on CEN/TR 17080 section 7.3.3.1)

VRk,s,l,x
Vcb
Ed,x ≤ VRd,s,l,x =
gMs,l,x
VRk,s,l,x = V0Rk,s,l,x · y l,V
y l,V = 1.0
gMs,l,x = ginst · gMs,l

Vcb
Ed,x [kN] V0Rk,s,l,x [kN] VRk,s,l,x [kN] gMs,l ginst gMs,l,x VRd,s,l,x [kN]
1.231 19.700 19.700 1.800 1.400 2.520 7.817

5.2.1.4 Anchor - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


3.003 39.600 1.500 26.400 13.889

5.2.1.5 Anchor - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080 section 7.2.2.2.2)
VRk,s,a,x
VaEd,x ≤ VRd,s,a,x =
gMs

VaEd,x [kN] VRk,s,a,x [kN] gMs VRd,s,a,x [kN]


1.231 18.400 1.500 12.267

5.2.1.6 Connection between anchor and channel - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


3.003 39.600 1.800 22.000 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.1.7 Connection between anchor and channel - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR
17080 section 7.2.2.2.3)

VRk,s,c,x
VaEd,x ≤ VRd,s,c,x =
gMs,ca

VaEd,x [kN] VRk,s,c,x [kN] gMs,ca VRd,s,c,x [kN]


1.231 12.500 1.800 6.944

5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.855 115 195 0.768
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
3.003 2.0 24.968 49.936 1.500 33.290

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.3 Concrete pry-out failure - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080
section 7.2.2.3)

VRk,cp,x
VaEd,x ≤ VRd,cp,x =
gMc
VRk,cp,x = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.823 - 195 1.000
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
115 115 0.768 0.768 1.000
VaEd,x [kN] k8 NRk,c [kN] VRk,cp,x [kN] gMc VRd,cp,x [kN]
1.231 2.0 18.463 36.925 1.500 24.617

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.4 Concrete edge failure - shear perpendicular, direction y- (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 115 22.973
s [mm] scr,V [mm] y ch,s,V
250 542 0.762
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
- - 271 1.000 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
10000 286 1.000 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
3.003 21.006 1.500 14.004

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.5 Concrete edge failure - shear longitudinal, direction y+ (Anchor a1, Channel a) (Hilti method based on EN 1992-4
section 7.2.2.5, CEN/TR 17080 section 7.2.2.4)

VRk,c,x
VaEd,x ≤ VRd,c,x =
gMc
Ac,V
VRk,c,x = V0Rk,c · · y s,V · y h,V · y re,V
A0c,V

V0Rk,c = k9 · danom · lbf · √fck · c1.5


1

0.5
a = 0.1 (cl )f
1

0.2
b = 0.1 (dc )nom
1

c2
y s,V = 0.7 + 0.3 ≤ 1.0
1.5 · c1
0.5
y h,V = (1.5h· c ) 1
≥ 1.0

k9 dnom [mm] l f [mm] a b fck [N/mm2] c1 [mm]


1.7 7 86 0.087 0.057 30.0 115
V0Rk,c [kN] Ac,V [mm2] A0c,V [mm2] c2 [mm] y s,V
17.598 102638 59513 - 1.000
h [mm] y h,V y a,V y re,V
10000 1.000 2.000 1.200
VaEd,x [kN] VRk,c,x [kN] gMc VRd,c,x [kN]
2.461 72.840 1.500 48.560

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Channel bolt (Fixture 1, Channel bolt 1.1)
2 2

(NN ) + (√V V + V ) ≤ 1.000


cb cb 2 cb 2
Ed Ed,y Ed,x
bN+V,s =
Rd,s,cb Rd,s,cb

2
=( ) = 0.02061
cb
N Ed
bN,s
N Rd,s,cb

2
=( ) = 0.00346
√V cb 2
+V
Ed,y
cb 2
Ed,x
bV,s
V Rd,s,cb

bN+V,s = (0.02061) + (0.00346) = 0.02407 ≤ 1.000


(Utilization : 3%)

5.3.2 Point of load application - channel lip (Fixture 1, Channel bolt 1.1)
k71 k71 2

(NN ; MM ) + (VV ) + (VV ) ≤ 1.0


cb ch cb cb
Ed Ed Ed,y Ed,x
bN+V,la,c = max
Rd,s,l Rd,s,flex Rd,s,l,y Rd,s,l,x

2.0
= max ( ) = 0.74907
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

2.0
=( ) = 0.03747
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.02478
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.74907 + 0.03747 + 0.02478 ≤ 1.0


(Utilization : 82%)

bN,la,c, governing failure mode: Channel lip


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: Flexure channel lip w/o lever arm - longitudinal

5.3.3 Anchor and connection between anchor and channel (Anchor a1)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
2.0
= max( )
a
N Ed NaEd
bN,ac , = 0.90146
N Rd,s,a NRd,s,c
2.0
= max( ) = 0.04676
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.03140
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.90146 + 0.04676 + 0.03140 ≤ 1.0

(Utilization : 98%)

bN,ac, governing failure mode: Connection anchor-channel


bV,ac,y, governing failure mode: Anchor - perpendicular
bV,ac,x, governing failure mode: Connection anchor/channel - longitudinal

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 16
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3.4 Concrete anchor (Anchor a1)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.70128
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.09932
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.01141
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.70128 + 0.09932 + 0.01141 = 0.81201 ≤ 1.0


(Utilization : 82%)

bN,c, governing failure mode: Concrete cone


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: Concrete edge - longitudinal

Remarks and warnings


• Results for longitudinal shear are calculated according to CEN/TR 17080 (Design of fastenings for use in concrete - Anchor
channels - Supplementary rules), EN 1992-4 (Eurocode 2: Design of concrete structures - Part 4: Design of fastenings for
use in concrete)
• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 98%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 17
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 300 mm x 150 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 150 x 20 x 10 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

150 150

75

75
1.1 1.2 x
75

75

60 180 60

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 18
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.2FSW+1.2(FWLS+FFL)+1.2x0.8FSL
Annex 5.3

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4, longitudinal shear as per Hilti method
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = ∞ mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: -25 mm

2 Overall Result
Design ok! (Maximum utilization: 83%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 150 x 20 x 10 mm
Standoff: No standoff
Plate dimensions: 300 mm x 150 mm x 10 mm
Anchorplate design calculated: no
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 10.440 2.534 1.055 -2.305
1.2 9.844 2.534 1.055 -2.305 1.1 1.2
Tension

max. concrete compressive strain: 0.08 [‰]


max. concrete compressive stress: 2.5 [N/mm2]
resulting tension force in (x/y)=(147.4/85.0): 20.284 [kN]
resulting compression force in (x/y)=(174.2/4.9): 4.314 [kN]
Compression
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.474 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] Vy [kN]
a1 11.455 -2.574
a2 8.828 -2.035

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
Anchor longitudinal shear forces [kN]
Anchor Vx
a1 1.055
a2 1.055

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 11.455 18.389 63 ok
Connection anchor-channel 11.455 13.889 83 ok
Channel lip 10.440 13.889 76 ok
Channel bolt 10.440 83.733 13 ok
Flexure channel 0.474 0.852 56 ok
Pull-out 11.455 31.350 37 ok
Concrete cone 11.455 16.705 69 ok
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

5.1.1 Steel failure (EN 1992-4 section 7.4.1.3)


5.1.1.1 Anchor (Anchor a1, Channel a)
NRk,s,a
NaEd ≤ NRd,s,a =
gMs

NaEd [kN] NRk,s,a [kN] gMs NRd,s,a [kN]


11.455 33.100 1.800 18.389

5.1.1.2 Connection between anchor and channel (Anchor a1, Channel a)


NRk,s,c
NaEd ≤ NRd,s,c =
gMs,ca

NaEd [kN] NRk,s,c [kN] gMs,ca NRd,s,c [kN]


11.455 25.000 1.800 13.889

5.1.1.3 Local flexure of channel lip (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s,l
Ncb
Ed ≤ NRd,s,l =
gMs,l
NRk,s,l = N0Rk,s,l · y l,N

y l,N = 0.5 · 1 + ( scbo


sl,N )
≤ 1.0

scbo [mm] sl,N [mm] y l,N


180 82 1.000
Ncb
Ed [kN] N0Rk,s,l [kN] NRk,s,l [kN] gMs,l NRd,s,l [kN]
10.440 25.000 25.000 1.800 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.1.1.4 Channel bolt (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s
Ncb
Ed ≤ NRd,s =
gMs

Ncb
Ed [kN] NRk,s [kN] gMs NRd,s [kN]
10.440 125.600 1.500 83.733

5.1.1.5 Flexure of channel (Channel a)


MRk,s,flex
Mch
Ed ≤ MRd,s,flex =
gMs,flex

Mch
Ed [kNm] MRk,s,flex [kNm] gMs,flex MRd,s,flex [kNm]
0.474 0.980 1.150 0.852

5.1.2 Pull-out failure (Anchor a1, Channel a) (EN 1992-4 section 7.4.1.4)
NRk,p
NaEd ≤ NRd,p =
gMp
NRk,p = k2 · Ah · fck

Ah [mm2]
209
NaEd [kN] k2 fck [N/mm2] NRk,p [kN] gMp NRd,p [kN]
11.455 7.5 30.0 47.025 1.500 31.350

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.1.3 Concrete cone (Anchor a1, Channel a) (EN 1992-4 section 7.4.1.5)
NRk,c
NaEd ≤ NRd,c =
gMc
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,N N0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5 · hef

0.5
y ch,c,N,1 = (cc ) 2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc ) 2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.858 115 195 0.768
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
NaEd [kN] NRk,c [kN] gMc NRd,c [kN]
11.455 25.058 1.500 16.705

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 2.534 50.240 6 ok
Flexure channel lip w/o lever arm - 2.305 13.889 17 ok
perpendicular
Flexure channel lip w/o lever arm - 1.055 7.817 14 ok
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 2.574 13.889 19 ok
Anchor - longitudinal 1.055 12.267 9 ok
Connection anchor/channel - 2.574 13.889 19 ok
perpendicular
Connection anchor/channel - 1.055 6.944 16 ok
longitudinal
Concrete pryout, perpendicular 2.574 33.290 8 ok
Concrete pryout, longitudinal 1.055 24.617 5 ok
Concrete edge - perpendicular 2.574 14.004 19 ok
Concrete edge - longitudinal 2.109 48.560 5 ok
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
2.534 2.305 1.055 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y )
≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


180 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
2.305 34.900 34.900 1.800 19.389 13.889

5.2.1.3 Local flexure of channel lip - shear longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (Hilti method
based on CEN/TR 17080 section 7.3.3.1)

VRk,s,l,x
Vcb
Ed,x ≤ VRd,s,l,x =
gMs,l,x
VRk,s,l,x = V0Rk,s,l,x · y l,V
y l,V = 1.0
gMs,l,x = ginst · gMs,l

Vcb
Ed,x [kN] V0Rk,s,l,x [kN] VRk,s,l,x [kN] gMs,l ginst gMs,l,x VRd,s,l,x [kN]
1.055 19.700 19.700 1.800 1.400 2.520 7.817

5.2.1.4 Anchor - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


2.574 39.600 1.500 26.400 13.889

5.2.1.5 Anchor - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080 section 7.2.2.2.2)
VRk,s,a,x
VaEd,x ≤ VRd,s,a,x =
gMs

VaEd,x [kN] VRk,s,a,x [kN] gMs VRd,s,a,x [kN]


1.055 18.400 1.500 12.267

5.2.1.6 Connection between anchor and channel - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


2.574 39.600 1.800 22.000 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.1.7 Connection between anchor and channel - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR
17080 section 7.2.2.2.3)

VRk,s,c,x
VaEd,x ≤ VRd,s,c,x =
gMs,ca

VaEd,x [kN] VRk,s,c,x [kN] gMs,ca VRd,s,c,x [kN]


1.055 12.500 1.800 6.944

5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.855 115 195 0.768
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
2.574 2.0 24.968 49.936 1.500 33.290

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.3 Concrete pry-out failure - shear longitudinal (Anchor a1, Channel a) (Hilti method based on CEN/TR 17080
section 7.2.2.3)

VRk,cp,x
VaEd,x ≤ VRd,cp,x =
gMc
VRk,cp,x = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.823 - 195 1.000
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
115 115 0.768 0.768 1.000
VaEd,x [kN] k8 NRk,c [kN] VRk,cp,x [kN] gMc VRd,cp,x [kN]
1.055 2.0 18.463 36.925 1.500 24.617

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.4 Concrete edge failure - shear perpendicular, direction y- (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 115 22.973
s [mm] scr,V [mm] y ch,s,V
250 542 0.762
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
- - 271 1.000 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
10000 286 1.000 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
2.574 21.006 1.500 14.004

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.5 Concrete edge failure - shear longitudinal, direction y+ (Anchor a1, Channel a) (Hilti method based on EN 1992-4
section 7.2.2.5, CEN/TR 17080 section 7.2.2.4)

VRk,c,x
VaEd,x ≤ VRd,c,x =
gMc
Ac,V
VRk,c,x = V0Rk,c · · y s,V · y h,V · y re,V
A0c,V

V0Rk,c = k9 · danom · lbf · √fck · c1.5


1

0.5
a = 0.1 (cl )f
1

0.2
b = 0.1 (dc )nom
1

c2
y s,V = 0.7 + 0.3 ≤ 1.0
1.5 · c1
0.5
y h,V = (1.5h· c ) 1
≥ 1.0

k9 dnom [mm] l f [mm] a b fck [N/mm2] c1 [mm]


1.7 7 86 0.087 0.057 30.0 115
V0Rk,c [kN] Ac,V [mm2] A0c,V [mm2] c2 [mm] y s,V
17.598 102638 59513 - 1.000
h [mm] y h,V y a,V y re,V
10000 1.000 2.000 1.200
VaEd,x [kN] VRk,c,x [kN] gMc VRd,c,x [kN]
2.109 72.840 1.500 48.560

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Channel bolt (Fixture 1, Channel bolt 1.1)
2 2

(NN ) + (√V V + V ) ≤ 1.000


cb cb 2 cb 2
Ed Ed,y Ed,x
bN+V,s =
Rd,s,cb Rd,s,cb

2
=( ) = 0.01554
cb
N Ed
bN,s
N Rd,s,cb

2
=( ) = 0.00254
√V cb 2
+V
Ed,y
cb 2
Ed,x
bV,s
V Rd,s,cb

bN+V,s = (0.01554) + (0.00254) = 0.01809 ≤ 1.000


(Utilization : 2%)

5.3.2 Point of load application - channel lip (Fixture 1, Channel bolt 1.1)
k71 k71 2

(NN ; MM ) + (VV ) + (VV ) ≤ 1.0


cb ch cb cb
Ed Ed Ed,y Ed,x
bN+V,la,c = max
Rd,s,l Rd,s,flex Rd,s,l,y Rd,s,l,x

2.0
= max ( ) = 0.56498
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

2.0
=( ) = 0.02753
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.01820
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.56498 + 0.02753 + 0.01820 ≤ 1.0


(Utilization : 62%)

bN,la,c, governing failure mode: Channel lip


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: Flexure channel lip w/o lever arm - longitudinal

5.3.3 Anchor and connection between anchor and channel (Anchor a1)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
2.0
= max( )
a
N Ed NaEd
bN,ac , = 0.68026
N Rd,s,a NRd,s,c
2.0
= max( ) = 0.03436
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.02306
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.68026 + 0.03436 + 0.02306 ≤ 1.0

(Utilization : 74%)

bN,ac, governing failure mode: Connection anchor-channel


bV,ac,y, governing failure mode: Anchor - perpendicular
bV,ac,x, governing failure mode: Connection anchor/channel - longitudinal

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 16
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3.4 Concrete anchor (Anchor a1)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.56783
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.07882
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.00905
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.56783 + 0.07882 + 0.00905 = 0.65570 ≤ 1.0


(Utilization : 66%)

bN,c, governing failure mode: Concrete cone


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: Concrete edge - longitudinal

Remarks and warnings


• Results for longitudinal shear are calculated according to CEN/TR 17080 (Design of fastenings for use in concrete - Anchor
channels - Supplementary rules), EN 1992-4 (Eurocode 2: Design of concrete structures - Part 4: Design of fastenings for
use in concrete)
• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 83%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 17
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 300 mm x 150 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 150 x 20 x 10 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

150 150

65

1.1 1.2 75
x
85

75

60 180 60

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 18
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 2
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
DESCRIPTION OF STRUCTURAL CALCULATION

6. Annex 6: Load capacity analysis of cast-in channel at location 3 level 12 to level 25/ Phụ lục 6: Phân tích khả
năng chịu lực của cast-in channel vị trí 3 tầng 12 đến tầng 25

Page 39/40
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.4FSW+1.4FWLP
Annex 6.1

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = ∞ mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: 25 mm

2 Overall Result
Design ok! (Maximum utilization: 20%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 120 x 20 x 10 mm
Standoff: No standoff
Plate dimensions: 340 mm x 120 mm x 10 mm
Anchorplate design calculated: no
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 0.407 0.971 0.000 0.971
1.2 0.000 3.660 0.000 -3.660
1.1 1.2
Tension
max. concrete compressive strain: 0.03 [‰] Compression
max. concrete compressive stress: 0.8 [N/mm2]
resulting tension force in (x/y)=(45.0/60.0): 0.407 [kN]
resulting compression force in (x/y)=(274.6/42.9): 6.480 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.020 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] V [kN]
a1 0.256 -0.148
a2 0.151 -2.541

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 0.256 18.389 2 ok
Connection anchor-channel 0.256 13.889 2 ok
Channel lip 0.407 13.889 3 ok
Channel bolt 0.407 83.733 1 ok
Flexure channel 0.020 0.852 3 ok
Pull-out 0.256 31.350 1 ok
Concrete cone 0.256 17.281 2 ok
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

5.1.1 Steel failure (EN 1992-4 section 7.4.1.3)


5.1.1.1 Anchor (Anchor a1, Channel a)
NRk,s,a
NaEd ≤ NRd,s,a =
gMs

NaEd [kN] NRk,s,a [kN] gMs NRd,s,a [kN]


0.256 33.100 1.800 18.389

5.1.1.2 Connection between anchor and channel (Anchor a1, Channel a)


NRk,s,c
NaEd ≤ NRd,s,c =
gMs,ca

NaEd [kN] NRk,s,c [kN] gMs,ca NRd,s,c [kN]


0.256 25.000 1.800 13.889

5.1.1.3 Local flexure of channel lip (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s,l
Ncb
Ed ≤ NRd,s,l =
gMs,l
NRk,s,l = N0Rk,s,l · y l,N

y l,N = 0.5 · 1 + ( scbo


sl,N )
≤ 1.0

scbo [mm] sl,N [mm] y l,N


180 82 1.000
Ncb
Ed [kN] N0Rk,s,l [kN] NRk,s,l [kN] gMs,l NRd,s,l [kN]
0.407 25.000 25.000 1.800 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.1.1.4 Channel bolt (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s
Ncb
Ed ≤ NRd,s =
gMs

Ncb
Ed [kN] NRk,s [kN] gMs NRd,s [kN]
0.407 125.600 1.500 83.733

5.1.1.5 Flexure of channel (Channel a)


MRk,s,flex
Mch
Ed ≤ MRd,s,flex =
gMs,flex

Mch
Ed [kNm] MRk,s,flex [kNm] gMs,flex MRd,s,flex [kNm]
0.020 0.980 1.150 0.852

5.1.2 Pull-out failure (Anchor a1, Channel a) (EN 1992-4 section 7.4.1.4)
NRk,p
NaEd ≤ NRd,p =
gMp
NRk,p = k2 · Ah · fck

Ah [mm2]
209
NaEd [kN] k2 fck [N/mm2] NRk,p [kN] gMp NRd,p [kN]
0.256 7.5 30.0 47.025 1.500 31.350

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.1.3 Concrete cone (Anchor a1, Channel a) (EN 1992-4 section 7.4.1.5)
NRk,c
NaEd ≤ NRd,c =
gMc
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,N N0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5 · hef

0.5
y ch,c,N,1 = (cc ) 2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc ) 2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.887 115 195 0.768
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
395 - 1.000 1.000 1.000
NaEd [kN] NRk,c [kN] gMc NRd,c [kN]
0.256 25.921 1.500 17.281

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 3.660 50.240 8 ok
Flexure channel lip w/o lever arm - 3.660 19.389 19 ok
perpendicular
Flexure channel lip w/o lever arm - N/A N/A N/A N/A
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 2.541 26.400 10 ok
Anchor - longitudinal N/A N/A N/A N/A
Connection anchor/channel - 2.541 22.000 12 ok
perpendicular
Connection anchor/channel - N/A N/A N/A N/A
longitudinal
Concrete pryout, perpendicular 2.541 33.172 8 ok
Concrete pryout, longitudinal N/A N/A N/A N/A
Concrete edge - perpendicular 2.541 13.144 20 ok
Concrete edge - longitudinal N/A N/A N/A N/A
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
3.660 3.660 0.000 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y)≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


180 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
3.660 34.900 34.900 1.800 19.389 19.389

5.2.1.3 Anchor - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


2.541 39.600 1.500 26.400 26.400

5.2.1.4 Connection between anchor and channel - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


2.541 39.600 1.800 22.000 22.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.988 115 195 0.768
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
145 - 0.862 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
2.541 2.0 24.879 49.758 1.500 33.172

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.3 Concrete edge failure - shear perpendicular, direction y- (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 115 22.973
s [mm] scr,V [mm] y ch,s,V
250 542 0.978
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
145 - 271 0.732 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
10000 286 1.000 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
2.541 19.716 1.500 13.144

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Channel bolt (Fixture 1, Channel bolt 1.1)
2 2

(NN ) + (√V V + V ) ≤ 1.000


cb cb 2 cb 2
Ed Ed,y Ed,x
bN+V,s =
Rd,s,cb Rd,s,cb

2
=( ) = 0.00002
cb
N Ed
bN,s
N Rd,s,cb

2
=( ) = 0.00037
√V cb 2
+V
Ed,y
cb 2
Ed,x
bV,s
V Rd,s,cb

bN+V,s = (0.00002) + (0.00037) = 0.00040 ≤ 1.000


(Utilization : 1%)

5.3.2 Point of load application - channel lip (Fixture 1, Channel bolt 1.1)
k71 k71 2

(NN ; MM ) + (VV ) + (VV ) ≤ 1.0


cb ch cb cb
Ed Ed Ed,y Ed,x
bN+V,la,c = max
Rd,s,l Rd,s,flex Rd,s,l,y Rd,s,l,x

2.0
= max ( ) = 0.00086
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

2.0
=( ) = 0.00489
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.00000
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.00086 + 0.00489 + 0.00000 ≤ 1.0


(Utilization : 1%)

bN,la,c, governing failure mode: Channel lip


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: N/A

5.3.3 Anchor and connection between anchor and channel (Anchor a2)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
1.0
= max( )
a
N Ed NaEd
bN,ac , = 0.01086
N Rd,s,a NRd,s,c
1.0
= max( ) = 0.11551
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.00000
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.01086 + 0.11551 + 0.00000 ≤ 1.0

(Utilization : 13%)

bN,ac, governing failure mode: Connection anchor-channel


bV,ac,y, governing failure mode: Connection anchor/channel - perpendicular
bV,ac,x, governing failure mode: N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3.4 Concrete anchor (Anchor a2)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.00136
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.08501
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.00000
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.00136 + 0.08501 + 0.00000 = 0.08637 ≤ 1.0


(Utilization : 9%)

bN,c, governing failure mode: Concrete cone


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: N/A

Remarks and warnings


• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 20%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 340 mm x 120 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 120 x 20 x 10 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

y
120

170 170

60

60
1.1 1.2 x
60

60

45 180 115

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.4FSW+1.4FWLS
Annex 6.2

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = ∞ mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: 0 mm

2 Overall Result
Design ok! (Maximum utilization: 86%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 120 x 20 x 10 mm
Standoff: No standoff
Plate dimensions: 340 mm x 120 mm x 10 mm
Anchorplate design calculated: no
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 3.016 0.971 0.000 0.971
1.2 11.902 3.660 0.000 -3.660
1.1 1.2
Tension
max. concrete compressive strain: 0.17 [‰]
max. concrete compressive stress: 5.7 [N/mm2]
Compression
resulting tension force in (x/y)=(188.6/60.0): 14.918 [kN]
resulting compression force in (x/y)=(28.9/13.2): 5.793 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.281 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] V [kN]
a1 5.236 -0.305
a2 9.682 -2.384

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 9.682 18.389 53 ok
Connection anchor-channel 9.682 13.889 70 ok
Channel lip 11.902 13.889 86 ok
Channel bolt 11.902 83.733 15 ok
Flexure channel 0.281 0.852 34 ok
Pull-out 9.682 31.350 31 ok
Concrete cone 9.682 15.044 65 ok
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

5.1.1 Steel failure (EN 1992-4 section 7.4.1.3)


5.1.1.1 Anchor (Anchor a2, Channel a)
NRk,s,a
NaEd ≤ NRd,s,a =
gMs

NaEd [kN] NRk,s,a [kN] gMs NRd,s,a [kN]


9.682 33.100 1.800 18.389

5.1.1.2 Connection between anchor and channel (Anchor a2, Channel a)


NRk,s,c
NaEd ≤ NRd,s,c =
gMs,ca

NaEd [kN] NRk,s,c [kN] gMs,ca NRd,s,c [kN]


9.682 25.000 1.800 13.889

5.1.1.3 Local flexure of channel lip (Fixture 1, Channel bolt 1.2, Channel a)
NRk,s,l
Ncb
Ed ≤ NRd,s,l =
gMs,l
NRk,s,l = N0Rk,s,l · y l,N

y l,N = 0.5 · 1 + ( scbo


sl,N )
≤ 1.0

scbo [mm] sl,N [mm] y l,N


180 82 1.000
Ncb
Ed [kN] N0Rk,s,l [kN] NRk,s,l [kN] gMs,l NRd,s,l [kN]
11.902 25.000 25.000 1.800 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.1.1.4 Channel bolt (Fixture 1, Channel bolt 1.2, Channel a)
NRk,s
Ncb
Ed ≤ NRd,s =
gMs

Ncb
Ed [kN] NRk,s [kN] gMs NRd,s [kN]
11.902 125.600 1.500 83.733

5.1.1.5 Flexure of channel (Channel a)


MRk,s,flex
Mch
Ed ≤ MRd,s,flex =
gMs,flex

Mch
Ed [kNm] MRk,s,flex [kNm] gMs,flex MRd,s,flex [kNm]
0.281 0.980 1.150 0.852

5.1.2 Pull-out failure (Anchor a2, Channel a) (EN 1992-4 section 7.4.1.4)
NRk,p
NaEd ≤ NRd,p =
gMp
NRk,p = k2 · Ah · fck

Ah [mm2]
209
NaEd [kN] k2 fck [N/mm2] NRk,p [kN] gMp NRd,p [kN]
9.682 7.5 30.0 47.025 1.500 31.350

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.1.3 Concrete cone (Anchor a2, Channel a) (EN 1992-4 section 7.4.1.5)
NRk,c
NaEd ≤ NRd,c =
gMc
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,N N0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5 · hef

0.5
y ch,c,N,1 = (cc ) 2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc ) 2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.896 115 195 0.768
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
145 - 0.862 1.000 1.000
NaEd [kN] NRk,c [kN] gMc NRd,c [kN]
9.682 22.565 1.500 15.044

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 3.660 50.240 8 ok
Flexure channel lip w/o lever arm - 3.660 13.889 27 ok
perpendicular
Flexure channel lip w/o lever arm - N/A N/A N/A N/A
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 2.384 13.889 18 ok
Anchor - longitudinal N/A N/A N/A N/A
Connection anchor/channel - 2.384 13.889 18 ok
perpendicular
Connection anchor/channel - N/A N/A N/A N/A
longitudinal
Concrete pryout, perpendicular 2.384 32.687 8 ok
Concrete pryout, longitudinal N/A N/A N/A N/A
Concrete edge - perpendicular 2.384 12.798 19 ok
Concrete edge - longitudinal N/A N/A N/A N/A
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
3.660 3.660 0.000 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y)≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


180 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
3.660 34.900 34.900 1.800 19.389 13.889

5.2.1.3 Anchor - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


2.384 39.600 1.500 26.400 13.889

5.2.1.4 Connection between anchor and channel - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


2.384 39.600 1.800 22.000 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.973 115 195 0.768
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
145 - 0.862 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
2.384 2.0 24.515 49.030 1.500 32.687

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.3 Concrete edge failure - shear perpendicular, direction y- (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 115 22.973
s [mm] scr,V [mm] y ch,s,V
250 542 0.952
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
145 - 271 0.732 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
10000 286 1.000 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
2.384 19.197 1.500 12.798

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Channel bolt (Fixture 1, Channel bolt 1.2)
2 2

(NN ) + (√V V + V ) ≤ 1.000


cb cb 2 cb 2
Ed Ed,y Ed,x
bN+V,s =
Rd,s,cb Rd,s,cb

2
=( ) = 0.02020
cb
N Ed
bN,s
N Rd,s,cb

2
=( ) = 0.00531
√V cb 2
+V
Ed,y
cb 2
Ed,x
bV,s
V Rd,s,cb

bN+V,s = (0.02020) + (0.00531) = 0.02551 ≤ 1.000


(Utilization : 3%)

5.3.2 Point of load application - channel lip (Fixture 1, Channel bolt 1.2)
k71 k71 2

(NN ; MM ) + (VV ) + (VV ) ≤ 1.0


cb ch cb cb
Ed Ed Ed,y Ed,x
bN+V,la,c = max
Rd,s,l Rd,s,flex Rd,s,l,y Rd,s,l,x

2.0
= max ( ) = 0.73433
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

2.0
=( ) = 0.06944
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.00000
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.73433 + 0.06944 + 0.00000 ≤ 1.0


(Utilization : 81%)

bN,la,c, governing failure mode: Channel lip


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: N/A

5.3.3 Anchor and connection between anchor and channel (Anchor a2)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
2.0
= max( )
a
N Ed NaEd
bN,ac , = 0.48593
N Rd,s,a NRd,s,c
2.0
= max( ) = 0.02946
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.00000
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.48593 + 0.02946 + 0.00000 ≤ 1.0

(Utilization : 52%)

bN,ac, governing failure mode: Connection anchor-channel


bV,ac,y, governing failure mode: Anchor - perpendicular
bV,ac,x, governing failure mode: N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3.4 Concrete anchor (Anchor a2)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.51631
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.08039
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.00000
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.51631 + 0.08039 + 0.00000 = 0.59670 ≤ 1.0


(Utilization : 60%)

bN,c, governing failure mode: Concrete cone


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: N/A

Remarks and warnings


• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 86%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 340 mm x 120 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 120 x 20 x 10 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

y
120

170 170

60

60
1.1 1.2 x
60

60

45 180 115

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.2FSW+1.2FWLS+1.2x0.8FSL
Annex 6.3

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = ∞ mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: 0 mm

2 Overall Result
Design ok! (Maximum utilization: 79%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 120 x 20 x 10 mm
Standoff: No standoff
Plate dimensions: 340 mm x 120 mm x 10 mm
Anchorplate design calculated: no
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 3.503 0.832 0.000 0.832
1.2 10.897 3.137 0.000 -3.137
1.1 1.2
Tension
max. concrete compressive strain: 0.17 [‰]
max. concrete compressive stress: 5.7 [N/mm2]
Compression
resulting tension force in (x/y)=(181.2/60.0): 14.400 [kN]
resulting compression force in (x/y)=(34.7/11.6): 6.136 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.261 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] V [kN]
a1 5.304 -0.262
a2 9.096 -2.043

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 9.096 18.389 50 ok
Connection anchor-channel 9.096 13.889 66 ok
Channel lip 10.897 13.889 79 ok
Channel bolt 10.897 83.733 14 ok
Flexure channel 0.261 0.852 31 ok
Pull-out 9.096 31.350 30 ok
Concrete cone 9.096 14.922 61 ok
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

5.1.1 Steel failure (EN 1992-4 section 7.4.1.3)


5.1.1.1 Anchor (Anchor a2, Channel a)
NRk,s,a
NaEd ≤ NRd,s,a =
gMs

NaEd [kN] NRk,s,a [kN] gMs NRd,s,a [kN]


9.096 33.100 1.800 18.389

5.1.1.2 Connection between anchor and channel (Anchor a2, Channel a)


NRk,s,c
NaEd ≤ NRd,s,c =
gMs,ca

NaEd [kN] NRk,s,c [kN] gMs,ca NRd,s,c [kN]


9.096 25.000 1.800 13.889

5.1.1.3 Local flexure of channel lip (Fixture 1, Channel bolt 1.2, Channel a)
NRk,s,l
Ncb
Ed ≤ NRd,s,l =
gMs,l
NRk,s,l = N0Rk,s,l · y l,N

y l,N = 0.5 · 1 + ( scbo


sl,N )
≤ 1.0

scbo [mm] sl,N [mm] y l,N


180 82 1.000
Ncb
Ed [kN] N0Rk,s,l [kN] NRk,s,l [kN] gMs,l NRd,s,l [kN]
10.897 25.000 25.000 1.800 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.1.1.4 Channel bolt (Fixture 1, Channel bolt 1.2, Channel a)
NRk,s
Ncb
Ed ≤ NRd,s =
gMs

Ncb
Ed [kN] NRk,s [kN] gMs NRd,s [kN]
10.897 125.600 1.500 83.733

5.1.1.5 Flexure of channel (Channel a)


MRk,s,flex
Mch
Ed ≤ MRd,s,flex =
gMs,flex

Mch
Ed [kNm] MRk,s,flex [kNm] gMs,flex MRd,s,flex [kNm]
0.261 0.980 1.150 0.852

5.1.2 Pull-out failure (Anchor a2, Channel a) (EN 1992-4 section 7.4.1.4)
NRk,p
NaEd ≤ NRd,p =
gMp
NRk,p = k2 · Ah · fck

Ah [mm2]
209
NaEd [kN] k2 fck [N/mm2] NRk,p [kN] gMp NRd,p [kN]
9.096 7.5 30.0 47.025 1.500 31.350

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.1.3 Concrete cone (Anchor a2, Channel a) (EN 1992-4 section 7.4.1.5)
NRk,c
NaEd ≤ NRd,c =
gMc
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,N N0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5 · hef

0.5
y ch,c,N,1 = (cc ) 2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc ) 2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.889 115 195 0.768
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
145 - 0.862 1.000 1.000
NaEd [kN] NRk,c [kN] gMc NRd,c [kN]
9.096 22.383 1.500 14.922

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 3.137 50.240 7 ok
Flexure channel lip w/o lever arm - 3.137 13.889 23 ok
perpendicular
Flexure channel lip w/o lever arm - N/A N/A N/A N/A
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 2.043 13.889 15 ok
Anchor - longitudinal N/A N/A N/A N/A
Connection anchor/channel - 2.043 13.889 15 ok
perpendicular
Connection anchor/channel - N/A N/A N/A N/A
longitudinal
Concrete pryout, perpendicular 2.043 32.687 7 ok
Concrete pryout, longitudinal N/A N/A N/A N/A
Concrete edge - perpendicular 2.043 12.798 16 ok
Concrete edge - longitudinal N/A N/A N/A N/A
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
3.137 3.137 0.000 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y)≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


180 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
3.137 34.900 34.900 1.800 19.389 13.889

5.2.1.3 Anchor - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


2.043 39.600 1.500 26.400 13.889

5.2.1.4 Connection between anchor and channel - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


2.043 39.600 1.800 22.000 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.973 115 195 0.768
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
145 - 0.862 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
2.043 2.0 24.515 49.030 1.500 32.687

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.2.3 Concrete edge failure - shear perpendicular, direction y- (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 115 22.973
s [mm] scr,V [mm] y ch,s,V
250 542 0.952
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
145 - 271 0.732 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
10000 286 1.000 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
2.043 19.197 1.500 12.798

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Channel bolt (Fixture 1, Channel bolt 1.2)
2 2

(NN ) + (√V V + V ) ≤ 1.000


cb cb 2 cb 2
Ed Ed,y Ed,x
bN+V,s =
Rd,s,cb Rd,s,cb

2
=( ) = 0.01694
cb
N Ed
bN,s
N Rd,s,cb

2
=( ) = 0.00390
√V cb 2
+V
Ed,y
cb 2
Ed,x
bV,s
V Rd,s,cb

bN+V,s = (0.01694) + (0.00390) = 0.02084 ≤ 1.000


(Utilization : 3%)

5.3.2 Point of load application - channel lip (Fixture 1, Channel bolt 1.2)
k71 k71 2

(NN ; MM ) + (VV ) + (VV ) ≤ 1.0


cb ch cb cb
Ed Ed Ed,y Ed,x
bN+V,la,c = max
Rd,s,l Rd,s,flex Rd,s,l,y Rd,s,l,x

2.0
= max ( ) = 0.61556
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

2.0
=( ) = 0.05103
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.00000
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.61556 + 0.05103 + 0.00000 ≤ 1.0


(Utilization : 67%)

bN,la,c, governing failure mode: Channel lip


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: N/A

5.3.3 Anchor and connection between anchor and channel (Anchor a2)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
2.0
= max( )
a
N Ed NaEd
bN,ac , = 0.42892
N Rd,s,a NRd,s,c
2.0
= max( ) = 0.02165
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.00000
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.42892 + 0.02165 + 0.00000 ≤ 1.0

(Utilization : 46%)

bN,ac, governing failure mode: Connection anchor-channel


bV,ac,y, governing failure mode: Anchor - perpendicular
bV,ac,x, governing failure mode: N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:
5.3.4 Concrete anchor (Anchor a2)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.47593
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.06380
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.00000
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.47593 + 0.06380 + 0.00000 = 0.53972 ≤ 1.0


(Utilization : 54%)

bN,c, governing failure mode: Concrete cone


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: N/A

Remarks and warnings


• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 79%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 340 mm x 120 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 120 x 20 x 10 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

y
120

170 170

60

60
1.1 1.2 x
60

60

45 180 115

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai Q3 Fastening point: Type 2 - Location 3
Phone | Fax: | Location | Date: 23/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
DESCRIPTION OF STRUCTURAL CALCULATION

7. Annex 7: Load capacity analysis of cast-in channel at location 4 level 12 to level 25/ Phụ lục 7: Phân tích khả
năng chịu lực của cast-in channel vị trí 4 tầng 12 đến tầng 25

Page 40/40
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.4FSW+1.4FWLP
Annex 7.1

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = 180 mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: -25 mm

2 Overall Result
Design ok! (Maximum utilization: 29%)

IMPORTANT! Failure analysis modes evaluated by PROFIS follow EOTA TR 047/EN 1992-4. This DOES NOT include
evaluating the base material (e.g. edge-of-slab) capacity to resist compressive forces generated by the fixture.  The engineer
must ALWAYS verify the base material (e.g. edge-of-slab) design is capable of resisting the applied loading.
Compressive forces generated by the fixture = 9.782 kN

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 220 x 10 x 0 mm
Standoff: No standoff
Plate dimensions: 220 mm x 243 mm x 10 mm
Anchorplate design calculated: no
1.1 1.2
Bolt N [kN] V [kN] Vx [kN] Vy [kN] Tension
1.1 3.609 2.386 0.000 2.386
1.2 3.483 3.814 0.000 3.814

max. concrete compressive strain: 0.07 [‰] Compression


max. concrete compressive stress: 2.4 [N/mm2]
resulting tension force in (x/y)=(108.8/183.0): 7.093 [kN]
resulting compression force in (x/y)=(113.2/96.0): 9.782 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.224 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] V [kN]
a1 3.982 3.229
a2 3.110 2.971

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 3.982 18.389 22 ok
Connection anchor-channel 3.982 13.889 29 ok
Channel lip 3.609 13.889 26 ok
Channel bolt 3.609 83.733 5 ok
Flexure channel 0.224 0.852 27 ok
Pull-out 3.982 31.350 13 ok
Concrete cone 3.982 15.548 26 ok
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

5.1.1 Steel failure (EN 1992-4 section 7.4.1.3)


5.1.1.1 Anchor (Anchor a1, Channel a)
NRk,s,a
NaEd ≤ NRd,s,a =
gMs

NaEd [kN] NRk,s,a [kN] gMs NRd,s,a [kN]


3.982 33.100 1.800 18.389

5.1.1.2 Connection between anchor and channel (Anchor a1, Channel a)


NRk,s,c
NaEd ≤ NRd,s,c =
gMs,ca

NaEd [kN] NRk,s,c [kN] gMs,ca NRd,s,c [kN]


3.982 25.000 1.800 13.889

5.1.1.3 Local flexure of channel lip (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s,l
Ncb
Ed ≤ NRd,s,l =
gMs,l
NRk,s,l = N0Rk,s,l · y l,N

y l,N = 0.5 · 1 + ( scbo


sl,N )
≤ 1.0

scbo [mm] sl,N [mm] y l,N


140 82 1.000
Ncb
Ed [kN] N0Rk,s,l [kN] NRk,s,l [kN] gMs,l NRd,s,l [kN]
3.609 25.000 25.000 1.800 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.1.1.4 Channel bolt (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s
Ncb
Ed ≤ NRd,s =
gMs

Ncb
Ed [kN] NRk,s [kN] gMs NRd,s [kN]
3.609 125.600 1.500 83.733

5.1.1.5 Flexure of channel (Channel a)


MRk,s,flex
Mch
Ed ≤ MRd,s,flex =
gMs,flex

Mch
Ed [kNm] MRk,s,flex [kNm] gMs,flex MRd,s,flex [kNm]
0.224 0.980 1.150 0.852

5.1.2 Pull-out failure (Anchor a1, Channel a) (EN 1992-4 section 7.4.1.4)
NRk,p
NaEd ≤ NRd,p =
gMp
NRk,p = k2 · Ah · fck

Ah [mm2]
209
NaEd [kN] k2 fck [N/mm2] NRk,p [kN] gMp NRd,p [kN]
3.982 7.5 30.0 47.025 1.500 31.350

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.1.3 Concrete cone (Anchor a1, Channel a) (EN 1992-4 section 7.4.1.5)
NRk,c
NaEd ≤ NRd,c =
gMc
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,N N0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5 · hef

0.5
y ch,c,N,1 = (cc ) 2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc ) 2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.856 100 195 0.716
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
NaEd [kN] NRk,c [kN] gMc NRd,c [kN]
3.982 23.322 1.500 15.548

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 3.814 50.240 8 ok
Flexure channel lip w/o lever arm - 3.814 13.889 28 ok
perpendicular
Flexure channel lip w/o lever arm - N/A N/A N/A N/A
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 3.229 13.889 24 ok
Anchor - longitudinal N/A N/A N/A N/A
Connection anchor/channel - 3.229 13.889 24 ok
perpendicular
Connection anchor/channel - N/A N/A N/A N/A
longitudinal
Concrete pryout, perpendicular 3.229 30.320 11 ok
Concrete pryout, longitudinal N/A N/A N/A N/A
Concrete edge - perpendicular N/A N/A N/A N/A
Concrete edge - longitudinal N/A N/A N/A N/A
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
3.814 3.814 0.000 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y)≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


140 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
3.814 34.900 34.900 1.800 19.389 13.889

5.2.1.3 Anchor - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


3.229 39.600 1.500 26.400 13.889

5.2.1.4 Connection between anchor and channel - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


3.229 39.600 1.800 22.000 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a1, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.835 100 195 0.716
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
3.229 2.0 22.740 45.479 1.500 30.320

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Channel bolt (Fixture 1, Channel bolt 1.2)
2 2

(NN ) + (√V V + V ) ≤ 1.000


cb cb 2 cb 2
Ed Ed,y Ed,x
bN+V,s =
Rd,s,cb Rd,s,cb

2
=( ) = 0.00173
cb
N Ed
bN,s
N Rd,s,cb

2
=( ) = 0.00576
√V cb 2
+V
Ed,y
cb 2
Ed,x
bV,s
V Rd,s,cb

bN+V,s = (0.00173) + (0.00576) = 0.00749 ≤ 1.000


(Utilization : 1%)

5.3.2 Point of load application - channel lip (Fixture 1, Channel bolt 1.2)
k71 k71 2

(NN ; MM ) + (VV ) + (VV ) ≤ 1.0


cb ch cb cb
Ed Ed Ed,y Ed,x
bN+V,la,c = max
Rd,s,l Rd,s,flex Rd,s,l,y Rd,s,l,x

2.0
= max ( ) = 0.06918
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

2.0
=( ) = 0.07542
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.00000
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.06918 + 0.07542 + 0.00000 ≤ 1.0


(Utilization : 15%)

bN,la,c, governing failure mode: Flexure channel


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: N/A

5.3.3 Anchor and connection between anchor and channel (Anchor a1)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
2.0
= max( )
a
N Ed NaEd
bN,ac , = 0.08221
N Rd,s,a NRd,s,c
2.0
= max( ) = 0.05405
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.00000
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.08221 + 0.05405 + 0.00000 ≤ 1.0

(Utilization : 14%)

bN,ac, governing failure mode: Connection anchor-channel


bV,ac,y, governing failure mode: Anchor - perpendicular
bV,ac,x, governing failure mode: N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3.4 Concrete anchor (Anchor a1)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.12962
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.03475
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.00000
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.12962 + 0.03475 + 0.00000 = 0.16437 ≤ 1.0


(Utilization : 17%)

bN,c, governing failure mode: Concrete cone


bV,c,y, governing failure mode: Concrete pryout, perpendicular
bV,c,x, governing failure mode: N/A

Remarks and warnings


• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The anchor plate overlaps the concrete base plate edges. A local concrete spalling due to compression close to the edges
has to be checked separately!
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 29%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 220 mm x 243 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 220 x 10 x 0 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

110 110

60

122
1.1 1.2

x
183
117

122

40 140 40

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.4FSW+1.4FWLS
Annex 7.2

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = 180 mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: 25 mm

2 Overall Result
Design ok! (Maximum utilization: 54%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 220 x 10 x 0 mm
Standoff: No standoff
Plate dimensions: 220 mm x 243 mm x 10 mm
Compression
Anchorplate design calculated: no
1.1 1.2
Bolt N [kN] V [kN] Vx [kN] Vy [kN]
1.1 0.000 3.587 0.000 -3.587
1.2 0.000 5.730 0.000 -5.730

max. concrete compressive strain: 0.01 [‰]


max. concrete compressive stress: 0.3 [N/mm2]
resulting tension force in (x/y)=(0/0): 0.000 [kN]
resulting compression force in (x/y)=(124.9/212.9): 2.689 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.000 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] V [kN]
a1 0.000 -3.762
a2 0.000 -5.555

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor N/A N/A N/A N/A
Connection anchor-channel N/A N/A N/A N/A
Channel lip N/A N/A N/A N/A
Channel bolt N/A N/A N/A N/A
Flexure channel N/A N/A N/A N/A
Pull-out N/A N/A N/A N/A
Concrete cone N/A N/A N/A N/A
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 5.730 50.240 12 ok
Flexure channel lip w/o lever arm - 5.730 19.389 30 ok
perpendicular
Flexure channel lip w/o lever arm - N/A N/A N/A N/A
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 5.555 26.400 22 ok
Anchor - longitudinal N/A N/A N/A N/A
Connection anchor/channel - 5.555 22.000 26 ok
perpendicular
Connection anchor/channel - N/A N/A N/A N/A
longitudinal
Concrete pryout, perpendicular 5.555 31.703 18 ok
Concrete pryout, longitudinal N/A N/A N/A N/A
Concrete edge - perpendicular 5.555 10.433 54 ok
Concrete edge - longitudinal N/A N/A N/A N/A
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
5.730 5.730 0.000 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y)≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


140 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
5.730 34.900 34.900 1.800 19.389 19.389

5.2.1.3 Anchor - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


5.555 39.600 1.500 26.400 26.400

5.2.1.4 Connection between anchor and channel - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


5.555 39.600 1.800 22.000 22.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.873 100 195 0.716
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
5.555 2.0 23.778 47.555 1.500 31.703

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:
5.2.3 Concrete edge failure - shear perpendicular, direction y- (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 100 19.067
s [mm] scr,V [mm] y ch,s,V
250 482 0.816
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
- - 241 1.000 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
180 256 0.839 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
5.555 15.650 1.500 10.433

Remarks and warnings


• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The anchor plate overlaps the concrete base plate edges. A local concrete spalling due to compression close to the edges
has to be checked separately!
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

Design ok! (Maximum utilization: 54%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 220 mm x 243 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 220 x 10 x 0 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

110 110

60

122
1.1 1.2

x
183
117

122

40 140 40

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 22/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 1
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
Specifier's comments: LV 19-25, Load case: 1.2FSW+1.2FWLS+1.2x0.8FSL
Annex 7.3

1 Input data
Channel type HAC-40 91/300 F
bolt HBC-C-N 8.8F, M16 x 50 mm
Effective embedment depth hef = 91 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 28 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 9/27/2019 | -
Standard EN 1992-4
Base material cracked, C30/37, fck,cylinder = 30.0 N/mm2, h = 180 mm
Reinforcement Exist. Reinf.: Widely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -25 mm/25 mm
most unfavorable tolerance: 25 mm

2 Overall Result
Design ok! (Maximum utilization: 49%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 2
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 3
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 4
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-C-N 8.8F, M16 x 50 mm
Profile: ; L x W x T = 220 x 10 x 0 mm
Standoff: No standoff
Plate dimensions: 220 mm x 243 mm x 10 mm Compression
Anchorplate design calculated: no
1.1 1.2
Bolt N [kN] V [kN] Vx [kN] Vy [kN] Tension
1.1 0.059 3.279 0.000 -3.279
1.2 0.000 5.136 0.000 -5.136

max. concrete compressive strain: 0.01 [‰]


max. concrete compressive stress: 0.4 [N/mm2]
resulting tension force in (x/y)=(40.0/183.0): 0.059 [kN]
resulting compression force in (x/y)=(125.2/223.0): 2.364 [kN]
Anchor forces are calculated based on the assumption of a rigid anchor plate.

4.2 Derivation of forces acting on anchor channels


NaEd,i = k · A'i · NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1

li = 13 · I0.05
y · s0.5 » 338 [mm] ≥ s
Iy = 21463 [mm4]
s = 250 [mm]
VaEd,i = k · A'i · VEd [kN]
MEd,y,max = 0.003 [kNm]

hef = 91

a1 a2

25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N [kN] V [kN]
a1 0.036 -3.410
a2 0.023 -5.005

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 5
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 0.036 18.389 1 ok
Connection anchor-channel 0.036 13.889 1 ok
Channel lip 0.059 13.889 1 ok
Channel bolt 0.059 83.733 1 ok
Flexure channel 0.003 0.852 1 ok
Pull-out 0.036 31.350 1 ok
Concrete cone 0.036 15.927 1 ok
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

5.1.1 Steel failure (EN 1992-4 section 7.4.1.3)


5.1.1.1 Anchor (Anchor a1, Channel a)
NRk,s,a
NaEd ≤ NRd,s,a =
gMs

NaEd [kN] NRk,s,a [kN] gMs NRd,s,a [kN]


0.036 33.100 1.800 18.389

5.1.1.2 Connection between anchor and channel (Anchor a1, Channel a)


NRk,s,c
NaEd ≤ NRd,s,c =
gMs,ca

NaEd [kN] NRk,s,c [kN] gMs,ca NRd,s,c [kN]


0.036 25.000 1.800 13.889

5.1.1.3 Local flexure of channel lip (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s,l
Ncb
Ed ≤ NRd,s,l =
gMs,l
NRk,s,l = N0Rk,s,l · y l,N

y l,N = 0.5 · 1 + ( scbo


sl,N )
≤ 1.0

scbo [mm] sl,N [mm] y l,N


140 82 1.000
Ncb
Ed [kN] N0Rk,s,l [kN] NRk,s,l [kN] gMs,l NRd,s,l [kN]
0.059 25.000 25.000 1.800 13.889

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 6
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.1.1.4 Channel bolt (Fixture 1, Channel bolt 1.1, Channel a)
NRk,s
Ncb
Ed ≤ NRd,s =
gMs

Ncb
Ed [kN] NRk,s [kN] gMs NRd,s [kN]
0.059 125.600 1.500 83.733

5.1.1.5 Flexure of channel (Channel a)


MRk,s,flex
Mch
Ed ≤ MRd,s,flex =
gMs,flex

Mch
Ed [kNm] MRk,s,flex [kNm] gMs,flex MRd,s,flex [kNm]
0.003 0.980 1.150 0.852

5.1.2 Pull-out failure (Anchor a1, Channel a) (EN 1992-4 section 7.4.1.4)
NRk,p
NaEd ≤ NRd,p =
gMp
NRk,p = k2 · Ah · fck

Ah [mm2]
209
NaEd [kN] k2 fck [N/mm2] NRk,p [kN] gMp NRd,p [kN]
0.036 7.5 30.0 47.025 1.500 31.350

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 7
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.1.3 Concrete cone (Anchor a1, Channel a) (EN 1992-4 section 7.4.1.5)
NRk,c
NaEd ≤ NRd,c =
gMc
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,N N0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5 · hef

0.5
y ch,c,N,1 = (cc ) 2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc ) 2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.877 100 195 0.716
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
NaEd [kN] NRk,c [kN] gMc NRd,c [kN]
0.036 23.891 1.500 15.927

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 8
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 5.136 50.240 11 ok
Flexure channel lip w/o lever arm - 5.136 19.389 27 ok
perpendicular
Flexure channel lip w/o lever arm - N/A N/A N/A N/A
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 5.005 26.400 19 ok
Anchor - longitudinal N/A N/A N/A N/A
Connection anchor/channel - 5.005 22.000 23 ok
perpendicular
Connection anchor/channel - N/A N/A N/A N/A
longitudinal
Concrete pryout, perpendicular 5.005 31.678 16 ok
Concrete pryout, longitudinal N/A N/A N/A N/A
Concrete edge - perpendicular 5.005 10.421 49 ok
Concrete edge - longitudinal N/A N/A N/A N/A
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (EN 1992-4 section 7.4.2.3)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN
1992-4 section 7.4.2.3, Hilti method based on CEN/TR 17080 section 7.2.2.2.1)

VRk,s
Vcb
Ed ≤ VRd,s =
gMs

Ed = √(VEd,y) + (VEd,x)
2 2
Vcb cb cb

Vcb
Ed [kN] Vcb
Ed,y [kN] Vcb
Ed,x [kN] VRk,s [kN] gMs VRd,s [kN]
5.136 5.136 0.000 62.800 1.250 50.240

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 9
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.2, Channel a) (EN 1992-4
section 7.4.2.3)

VRk,s,l,y
Vcb
Ed,y ≤ VRd,s,l,y =
gMs,l
VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y)≤ 1.0

VRd,s,l,y = min(VRd,s,l,y,ETA, NRd,s,l)

scbo [mm] sl,V,y [mm] y l,V


140 82 1.000
Vcb
Ed,y [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] gMs,l VRd,s,l,y,ETA [kN] VRd,s,l,y [kN]
5.136 34.900 34.900 1.800 19.389 19.389

5.2.1.3 Anchor - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,a,y
VaEd,y ≤ VRd,s,a,y =
gMs
VRd,s,a,y = min(VRd,s,a,y,ETA, NRd,s,a, NRd,s,c)

VaEd,y [kN] VRk,s,a,y [kN] gMs VRd,s,a,y,ETA [kN] VRd,s,a,y [kN]


5.005 39.600 1.500 26.400 26.400

5.2.1.4 Connection between anchor and channel - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.3)
VRk,s,c,y
VaEd,y ≤ VRd,s,c,y =
gMs,ca
VRd,s,c,y = min(VRd,s,c,y,ETA, NRd,s,c, NRd,s,a)

VaEd,y [kN] VRk,s,c,y [kN] gMs,ca VRk,s,c,y,ETA [kN] VRd,s,c,y [kN]


5.005 39.600 1.800 22.000 22.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 10
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.4)
VRk,cp,y
VaEd,y ≤ VRd,cp,y =
gMc
VRk,cp,y = k8 · NRk,c
NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N
N0Rk,c = k1 · √fck · h1.5
ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc )
cr,N
1
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 fck [N/mm2] hef [mm] N0Rk,c [kN]


8.0 30.0 91 38.038
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
250 390 0.872 100 195 0.716
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
- - 1.000 1.000 1.000
VaEd,y [kN] k8 NRk,c [kN] VRk,cp,y [kN] gMc VRd,cp,y [kN]
5.005 2.0 23.758 47.517 1.500 31.678

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 11
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.2.3 Concrete edge failure - shear perpendicular, direction y- (Anchor a2, Channel a) (EN 1992-4 section 7.4.2.5)
VRk,c,y
VaEd,y ≤ VRd,c,y =
gMc
VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V
V0Rk,c = k12 · √fck · c4/3
1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch
0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = ( )
c2,2
ccr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch


0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 fck [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 30.0 100 19.067
s [mm] scr,V [mm] y ch,s,V
250 482 0.815
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
- - 241 1.000 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
180 256 0.839 1.000 1.200
VaEd,y [kN] VRk,c,y [kN] gMc VRd,c,y [kN]
5.005 15.632 1.500 10.421

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 12
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3 Combined tension and shear loads ( EN 1992-4 section 8.3.3, Hilti method based on CEN/TR 17080 section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Channel bolt (Fixture 1, Channel bolt 1.1)
2 2

(NN ) + (√V V + V ) ≤ 1.000


cb cb 2 cb 2
Ed Ed,y Ed,x
bN+V,s =
Rd,s,cb Rd,s,cb

2
=( ) = 0.00000
cb
N Ed
bN,s
N Rd,s,cb

2
=( ) = 0.00426
√V cb 2
+V
Ed,y
cb 2
Ed,x
bV,s
V Rd,s,cb

bN+V,s = (0.00000) + (0.00426) = 0.00426 ≤ 1.000


(Utilization : 1%)

5.3.2 Point of load application - channel lip (Fixture 1, Channel bolt 1.2)
k71 k71 2

(NN ; MM ) + (VV ) + (VV ) ≤ 1.0


cb ch cb cb
Ed Ed Ed,y Ed,x
bN+V,la,c = max
Rd,s,l Rd,s,flex Rd,s,l,y Rd,s,l,x

1.0
= max ( ) = 0.00067
cb ch
N M Ed Ed
bN,la,c ;
N M Rd,s,l Rd,s,flex

1.0
=( ) = 0.26490
cb
V Ed,y
bV,la,c,y
V Rd,s,l,y

2
=( ) = 0.00000
cb
V Ed,x
bV,la,c,x
V Rd,s,l,x

bN+V,la,c = 0.00067 + 0.26490 + 0.00000 ≤ 1.0


(Utilization : 27%)

bN,la,c, governing failure mode: Flexure channel


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: N/A

5.3.3 Anchor and connection between anchor and channel (Anchor a2)
k72 k72 2
bN+V,ac = max( NaEd
,
NaEd
NRd,s,a NRd,s,c ) + max ( VaEd,y Va
, Ed,y
VRd,s,a,y VRd,s,c,y ) + max( VaEd,x Va
, Ed,x
VRd,s,a,x VRd,s,c,x ) ≤ 1.0
1.0
= max( )
a
N Ed NaEd
bN,ac , = 0.00168
N Rd,s,a NRd,s,c
1.0
= max( ) = 0.22749
a
V Ed,y VaEd,y
bV,ac,y ,
V Rd,s,a,y VRd,s,c,y
2
= max( ) = 0.00000
a
V Ed,x VaEd,x
bV,ac,x ,
V Rd,s,a,x VRd,s,c,x
bN+V,ac = 0.00168 + 0.22749 + 0.00000 ≤ 1.0

(Utilization : 23%)

bN,ac, governing failure mode: Connection anchor-channel


bV,ac,y, governing failure mode: Connection anchor/channel - perpendicular
bV,ac,x, governing failure mode: N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 13
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:
5.3.4 Concrete anchor (Anchor a2)
a a a
bN+V,c =( NaEd
NRd ) ( ) ( ) ≤ 1.0
+
VaEd,y
VRd,y
+
VaEd,x
VRd,x
1.5
=( ) = 0.00007
a
N Ed
bN,c
N Rd

1.5
=( ) = 0.33282
a
V Ed,y
bV,c,y
V Rd,y

1.5
=( ) = 0.00000
a
V Ed,x
bV,c,x
V Rd,x

bN+V,c = 0.00007 + 0.33282 + 0.00000 = 0.33289 ≤ 1.0


(Utilization : 34%)

bN,c, governing failure mode: Concrete cone


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: N/A

Remarks and warnings


• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The anchor plate overlaps the concrete base plate edges. A local concrete spalling due to compression close to the edges
has to be checked separately!
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of EN 1992-4 Annex A, section 10, and the structurally required reinforcement
has to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in EOTA
TR 047 and/or EC2.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 49%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 14
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-C-N 8.8F, M16 x 50 mm
Plate dimensions: 220 mm x 243 mm x 10 mm Bolt length: 50 mm
Profile: ; L x W x T = 220 x 10 x 0 mm Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.185 kNm

110 110

60

122
1.1 1.2

x
183
117

122

40 140 40

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Vietnam.html PROFIS Anchor Channel 1.7.5
Company: Hilti Vietnam Page: 15
Specifier: Project: Lancaster Luminaire
Address: 198 Nguyen Thi Minh Khai D3 Fastening point: Type 2 - Location 4
Phone | Fax: | Location | Date: 20/04/2021
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like