SAUDI ARAMCO ID/PID - 2/19/05 - REV 0 (Standards Cutoff - August 2004)

SAIC NUMBER DATE APPROVED QR NUMBER


SAUDI ARAMCO INSPECTION CHECKLIST
Inspection /Verification of Radiographic Testing Devices,
SAIC-RT-2004 25-May-05 NDE-
Monitors and Safety Equipment.
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
A Radiographic Testing Devices
Radiation Source is one of the following: (Check type of source)
1. X-ray generators (up to 6 MeV)
2. Iridium 192 (Ir-192) (up to 200 Ci) SAEP-1143,
A1 3. Cobalt 60 (Co-60) (up to 100 Ci) Para. 6.1 &
4. Selenium 75 (Se-75) (up to 50 Ci) Para. 8.1.2
Note: Use of Co-60 is only permitted when the thickness of the
material exceeds the practical limits of Ir-192 or Se-75.

All sealed sources, i.e; Iridium 192 (Ir-192), Cobalt 60 (Co-60),. Selenium
75 (Se-75) are housed in approved, remote operated, or shielded SAEP-1141
A2
projector type devices. Para. 10.1.1

Levels of radiation for the isotope projector shall not exceed the
following limits when a radioactive source is in its shielded position
(inside the storage camera):
1. The radiation level at 15 cm.(6 inches) from any
surface shall not exceed the limitations set forth by the SAEP-1141
A3
manufacturer of the equipment. Para. 10.1.3
2. The maximum radiation reading 4 inches (10 cm) from any exterior
surface, shall not exceed 200 mR per hour, or shall not exceed
10 mR per hour three feet (90 cm) from any exterior surface.

New sources shall be accompanied by a certificate that leak tests were


performed prior to shipment.
Note: Leak testing shall be conducted, using a procedure capable of SAEP-1141
A4
detecting the presence of 0.005 microcuries of removable Para. 7.1
contamination at the equipment associated with sealed source.

Radiographic exposure devices are provided with a lock designed to


prevent unauthorized or accidental removal or exposure of a sealed
source. SAEP-1141
A5 Note: If the exposure device (isotope projector) lock become Para. 7.1
inoperative, the isotope projector will immediately be taken
out of service for repair by authorized personnel.

SAEP-1141
A6 X-Ray Equipments control system are provided with a locking device.
Sec.14

Isotope exposure device accessories such as Wind-Out and Guide SAEP-1141


A7
Tubes are free of damages cuts and kinks. Para. 13.2

X-Ray equipment control and indicator assembly are free of loose


SAEP-1141
A8 hardware and damage. Control cables are free of cuts, breaks, and
Para. 13.2
broken fittings.

B Radiation Monitoring Equipment

Radiation survey instrument having a minimum range of two SAEP-1141


B1
milliroentgens per hour to one roentgen per hour are provided. Para. 5.1

Page 1 of 3
SAUDI ARAMCO ID/PID - 2/19/05 - REV 0 (Standards Cutoff - August 2004)
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Inspection /Verification of Radiographic Testing Devices,
SAIC-RT-2004 25-May-05 NDE-
Monitors and Safety Equipment.
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

0 0 0
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Radiation survey instrument are calibrated and operable.
Note: Radiation survey instruments shall be calibrated every SAEP-1141
B2
six (6) months. Each survey instrument shall carry a tag Para. 5.1& 5.2
showing the calibration and expiration dates
Pocket dosimeter capable of measuring doses from zero to 200 SAEP-1141
B3 milliroentgens are provided. Para. 4.1.1
Dosimeter Chargers are also provided for charging the dosimeters. Para. 4.1.4
SAEP-1141
B4 Thermal Luminescent/ personnel dosimeter are provided.
Para. 4.1.1

C Safety Equipments

Radiation Warning Signs are made in English and Arabic with a sign
bearing the radiation caution symbol, red (magenta) on yellow
background. The required radiation warning signs are as follows:
a. "Caution - Radiation Area" - for posting at the storage areas of
Isotope and at the perimeter of Radiographic work area.
(Para. 7.4)
b. "Danger, Radiation" - for posting on the front and rear of
vehicles transporting the isotope. See Standard Drawing SAEP-1141
C1
AB-036895 provided as shown in Attachment 1. (Para. 8.8) Para. 7.4
c. "Caution High Radiation Area" - for posting in areas where
space limitations do not allow the boundary to be established
at less than, or equal to, 2 mR per hour. (Para. 9.2)
d. "WARNING: KEEP A DISTANCE OF 100 METERS AROUND
THIS VEHICLE UNTIL HELP ARRIVES". This sign is affixed to
the top and inside cover of the isotope projector box.
(Para. 11.1.4)

All Saudi Aramco or contractor radiographic crews have a copy of the SAEP-1141
C7
Radiation Safety Manual in their vehicle or work location at all times. Para. 7.4

REMARKS:

REFERENCE DOCUMENTS:
1. SAEP-1143, Radiographic Examination, (29 May, 2002)
2. SAEP-1141, Industrial Radiation Safety, (31 December, 1996)

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED

Page 2 of 3