You are on page 1of 3

Tony Peda

From: Sunny Wong <SunnyW@tilling.com.au>


Sent: Friday, 14 September 2018 9:52 AM
To: pedaconsulting@gmail.com
Subject: BAL29 - TILLING
Attachments: BAL 29.pdf

Hi,

Attached are the requirements for BAL 29.

Properties are as below:

Red Alert SmartLVL11 (max. supply length = 12m)


f’b (edge) = 38 MPa (**For beams with a depth greater than 90, multiply by (90/d)^0.197.
f’b (flat) = 38 MPa (**For LVL on the flat with a thickness greater than 45, multiply by (45/t)^0.333.
f’t = 24 MPa (**For tension members with the larger cross sectional dimension exceeding 150mm multiply by
(150/d)^0.197 where d is the depth
f’s = 3.1 MPa
f’c = 23 MPa
Strength Group = SD6
Joint Group = JD4
f’p = 9.5 MPa
f’sj = 3.1 MPa
E = 11700 MPa
G = 585 MPa
J2 = 2

SmartLVL14 (max. supply length = 12m)


f’b (edge) = 50 MPa (**For beams with a depth greater than 90, multiply by (90/d)^0.15.
f’b (flat) = 50 MPa (**For LVL on the flat with a thickness greater than 45, multiply by (45/t)^0.333.
f’t = 25 MPa (**For tension members with the larger cross sectional dimension exceeding 150mm multiply by
(150/d)^0.167 where d is the depth
f’s = 4.2 MPa
f’c = 42 MPa
Strength Group = SD6
Joint Group = JD4
f’p = 12 MPa
f’sj = 5.2 MPa
E = 14000 MPa
G = 700 MPa
J2 = 2

SmartLVL15 (max. supply length = 12m)


f’b (edge) = 59 MPa (**For beams with a depth greater than 90, multiply by (90/d)^0.197.
f’b (flat) = 46 MPa (**For LVL on the flat with a thickness greater than 45, multiply by (45/t)^0.333.
f’t = 35 MPa (**For tension members with the larger cross sectional dimension exceeding 150mm multiply by
(150/d)^0.197 where d is the depth
f’s = 4.2 MPa
f’c = 39 MPa
Strength Group = SD6
1
Joint Group (face) = JD3
Joint Group (edge & end) = JD4
f’p = 12 MPa
f’sj = 5.2 MPa
E = 15500 MPa
G = 775 MPa
J2 = 2

SmartLVL19 (max. supply length = 7.2m)


f’b (edge) = 72MPa (**For beams with a depth greater than 300, multiply by (300/d)^0.167.
f’t = 47 MPa
f’s = 6.4 MPa
f’c = 45 MPa
Strength Group = SD3
Joint Goup = JD4
f’p = 19 MPa
f’sj = 7.3 MPa
E = 19500 MPa
G = 975 MPa
J2 = 2

GL18C (max. supply length = 7.2m)


f’b (edge) = 45MPa (**For beams with a depth greater than 300, multiply by (300/d)^0.167.
f’t = 25 MPa
f’s = 5 MPa
f’c = 45 MPa
Strength Group = SD3
Joint Goup = JD4
f’p = 20 MPa
f’sj = 7.2 MPa
E = 18500 MPa
G = 1230 MPa
J2 = 2

Kind Regards
Sunny Wong
Structural Engineer

Download our free design software, SmartFrame, at: https://www.tilling.com.au/wp-


content/uploads/software/SmartFrameV1401_SetupFull_WIN_Vista_7_8_10.exe

31-45 Orchard Street | Kilsyth | Melbourne | 3137


p 03 9725 0222 f 03 9725 3045
e SunnyW@tilling.com.au w www.tilling.com.au

2
This message contains confidential information and is intended only for the individual named. If you are not the named addressee you should not
disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete
this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted,
lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the
contents of this message. Finally, the recipient should check this email and any attachments for the presence of viruses. Tilling Timber accepts no
liability for any damage caused by any virus transmitted by this email.