You are on page 1of 1
MAGNETIC PARTICLE INSPECTION | REPORT Ne. O7 - eo “a CLIENT CONTRACTOR LOCATION, | GLEE ‘AGOCO FERRSTAAL een | Fogincering SHEET 1 OF 1 SARIR OILFIELD - i Construction Dept. | EC 0 Taknia ‘onstruction Dept 10462/201 REQUEST Ne. 122 | (ECD) | MATERIAL WELD PROCESS | EQUIPMENT | CONTACT SPACING Carbon Steel GTAW |__ Permanent Magnet __| 4~6 cm. SIZE THICKNESS | TYPE | CONTRAST PAINT 3/4"0 Sch.80 | Magnoflux WCP-2. Magnaflux SCHEDULE, PREPARATION | SURFACE COND’N. MAGNETIC INK Standard Fillet Weld As welded 7HE Magnaflux LINE IDENTIFICATION ‘AREA 3" C-40011-A1 6C-3 DRAWING Ne. | ACCEPTANCE STD. WELD CLASS N/A ANSI 831.3 10% SPOOL / ITEM Ne. OPERATOR DATE NA JV,R.EAE 03 APRIL. 2020 WELD | wipRr | WELD pent, | DIA: | SCH. mel area | TYPE INTERPRETATION RESULT sw27| 3/4” | 80 Fio | 100% | NIPOLET NSD A sw 28 | 3/4” | 80 F10 | 100% | FLANGE NSD A eet | *NOTHING FOLLOWS* re | — COMMENT / SKETCH COMPANY TAKNIA AGOCO AGOCO -Sarir NAME Rey Eduardo Ae ined # le - DESIGNATION STAnspgetor Ved Gear E.C.D Dept. Cgdtdinator SIGNATURE | (\CIpial” See Z DATE 04 April 2020 2S 04 April 2020 LEGEND: NSW NOSIGNIFICANT DEFECT PG-POROSTY LP LACK OF FUSION A nccerTeD NIRSD- NO REJECTABLE SIGNIFICANT DEFECT CK CRACK. SUe- UNDERCUT H-REPAIR