You are on page 1of 1
MAGNETIC PARTICLE INSPECT: a od a BCTION || pcport no. 42 - CLIENT CONTRACTOR LOCATION Eble | 46000 SHEET 1 oF 1 sane Engineering FERROSTAAL | saRIR OILFIELD : i Construction Dept. | _ £CD462/2010 GC-2 Taknia tuction Dep 1: REQUEST Ne. 1-22 (ECD) MATERIAL WELD PROCESS EQUIPMENT CONTACT SPACING Carbon Steel GTAW Permanent Magnet 4~6.m. SIZE THICKNESS TYPE ‘CONTRAST PAINT 0 455mm Magnaflux WCP-2 Magnaflux ‘SCHEDULE PREPARATION ‘SURFACE COND'N. MAGNETIC INK Sch.80 Fillet Weld ‘As welded HF Magnaflux LINE IDENTIFICATION ‘AREA 1-NG40024-A1-HC GC-2 DRAWING No. ‘ACCEPTANCE STD. WELD CLASS 2385-NM-1350-102 ANSI 831.3 | 10% ‘SPOOL / ITEM No. OPERATOR | DATE N/A JV,REAE |__22 uy 2020 WELD | WLpR | WELD went, | IA | SCH. Ne | AREA TYPE INTERPRETATION RESULT sw93] 2” | 80 | For | 100% PIPE NSD ia swis3| 1” | 80 Fo1 | 100% PIPE NSD A - = — " = _ *NOTHING FOLLOWS* | | | ‘ COMMENT / SKETCH COMPANY TAKNIA] Yj" ‘AGOCO, ‘AGOCO -Sarir NAME Bey Eduardo q Abdul Hamed S, | DESIGNATION (NoTipspettor® C.D Dept. Coordinator SIGNATURE 2 BSS Ao, DATE JULY 2020 2JULY 2020 LEGEND: : Los . NSHP NOSIGNIFICANT DEFECT PG-PoRosty | —_LE~ Lack oF FUSION A-AccePTED [NMESID- NO REJECTABLE SIGNIFICANT DEFECT CK ~ CRACK SUC- UNDERCUT RR-RePaR