You are on page 1of 1
MAGNETIC PARTICLE INSPECTION REPORT No, 54 CLIENT. CONTRACTOR | LOCATION AgocO SHEET 1 Engineering FERROSTAAL | ‘sariR OILFIELD aa T i Construction Dept. | _ £C0462/2010 cca Taknia ee it | REQUEST No. 1-22 (E.C0) MATERIAL WELD PROCESS — | EQUIPMENT CONTACT SPACING ~ Carbon Steel GTAW Permanent Magnet 4~6.cm. SIZE THICKNESS TYPE CONTRAST PAINT 3/4"dia As per request Magnaflux WCcP-2_ Magnaflux SCHEDULE PREPARATION ‘SURFACE COND'N. MAGNETIC INK AS BELOW Fillet Weld As welded 7HF Magnaflux LINE IDENTIFICATION ] AREA 6-NG-30103-B1-PP | GC-4 DRAWING No. ‘ACCEPTANCE STD. WELD CLASS ANSI 831.3 10% SPOOL / ITEM No. OPERATOR DATE N/A JV,REAE 01 AUGUST 2020 WELD WLbR | WELD tent, | DIA: | cH. ne fanen | TPE: INTERPRETATION RESULT sw2_[3/4” [ci3000[ F10 [100% | NIPOLET NSD |r sw3 | 3/4” | ciz000 | F10 | 100% | VALVE NSD A sw4 | 3/4” | 160 | F10 | 100% | _NIPPLE NSD A sw 16 | 3/4” | c13000 NIPOLET NSD [a sw 17_| 3/4” | c12000 VALVE NSD A sw 1s | 3/4” [160 NIPPLE NSD A + = <== > =NOTHING FOLLOWS® | a | ——~} = | al [ COMMENT / SKETCH : COMPANY (VT eTAKNIA\ =) AGOCO AGOCO -Sarir NAME 1 Rey Eduardo |) Abdul Hamed S, DESIGNATION IT Inspestor EC.D.dapt Coprdinator SIGNATURE ; Su | DATE AUGUST 2020 \UGUST 2020 LEGEND: 'NSID— No SiGwirican DEFECT PG-POROSTY LP LACK OF FUSION A-accePTED NIESD-NO REJECTABLE SIGNIFICANT DEFECT CK — CRACK SuC- UNDERCUT m-aePaR