You are on page 1of 1
VETIC PARTICLE INSPECTION =~0.2 _| REPORT Ne. 09 = um CLIENT CONTRACTOR LOCATION - jelae} FER: ingineering - SARIR OILFIELD }———~ ~ i Construction Dept. ECD462/2019 Takia | crmecin oer | eee [nur (ECD) | MATERIAL WELD PROCESS EQUIPMENT CONTACT SPACING Carbon Steel GTAW. Permanent Magnet 4~6cm. SIZE | THICKNESS: ‘TYPE CONTRAST PAINT 3/4"0. Sch.80 Magnaflux. WCP-2 Magnoflux SCHEDULE PREPARATION SURFACE COND’N. MAGNETIC INK Standard Fillet Weld As welded 7HF Magnoflux LINE IDENTIFICATION. AREA 4” NG-40003-A1 GC-3 DRAWING Ne. ACCEPTANCE STD. ‘WELD CLASS N/A ANSI 831.3, 10% ‘SPOOL / ITEM No. OPERATOR DATE N/A JV,R.E,AE 03 APRIL 2020 WELD WLDR WELD IDENT. DIA. | SCH. Ne AREA TYPE INTERPRETATION RESULT sws | 3/4” 80 F10 100% | NIPOLET NSD A swe | 3/4” 80 F10 100% | FLANGE NSD A < > | * z . *NOTHING FOLLOWS* — 7 | ‘COMMENT / SKETCH : COMPANY TAKNIA. AGOCO, AGOCO -Sarir NAME_ Rey Eduardo Ted Hilo: | Ahitd Alawjal. DESIGNATION \MOT|Inspector (ae: E.C.D Dept. Coordinator SIGNATURE Cin = ke DATE “OF April 2020 S4- 22d 04 ApMt2020 LEGEND: ‘NSD = NOSIGNICANT DEFECT PG-POROSITY LF LACK OF FUSION A-AccEPTED NWSI NOREIECTABLE SIGNIFICANT DESECT. CK CRACK suc-uNoeRcuT me atPain