ETIC DLE INSPECTI! 4 = GN iC PARTICLE INSPEC t iON REPORT No. 23 - (<) os CLIENT [__ CONTRACTOR LOCATION _ EEDA agoco SHEET 1 oF 1 mm mmm | Engineering | FERROSTAAL | sarin OILFIELD i Construction Dept. | £CD462/2015 6c3 Taknia ee Ca if REQUEST Ne, 1-22 (ECD) MATERIAL WELD PROCESS EQUIPMENT CONTACT SPACING Carbon Stee! GTAW Permanent Magnet 4~6cm. SIZE THICKNESS TYPE ‘CONTRAST PAINT 1/2" 3.91mm Magnaflux WCP.2 Magnaflux ‘SCHEDULE PREPARATION SURFACE COND’N. MAGNETIC INK Sch.80 Fillet Weld As welded 7HF Magnoflux LINE IDENTIFICATION ‘AREA FL-UTILITY PIPING 8-322 Gc-3 DRAWING Ne. ACCEPTANCE STD. | WELD CLASS GC-3_ZEC1900295-PL-DR ANS! 831.3 100 % SPOOL / ITEM Ne. OPERATOR DATE N/A JV,REAE 15 JUNE 2020 WELD wipr | WELD ipenr, | DIA: | SCH. Ne farca | TPE INTERPRETATION RESULT Fw2 | 1” | 80 Fo1__| 100% | SOCKET NSD A Fw3 | 1” | 80 Fo1__| 100% | SOCKET NSD a__| rwa | 2” | 80 | For | 100% | SOCKET: NSD A < 3 *NOTHING FOLLOWS* z — . ‘ COMMENT / SKETCH SNR COMPANY PecTaknay’ =] AGOCO ‘AGOCO -Sar NAME ReyEduardo | ABDuc HANED DESIGNATION SADT Inspector E.C.D Dept. Coordinator SIGNATURE 2 DATE {JUNE 2020 16 JUNE 2020 LEGEND: ‘ : NSD NOSIGNIFICANT DEFECT PG-PoROSTY LF Lack OF FUSION A ACCEPTED 1D. NO REJECTASLE SIGNIFICANT DEFECT CK—CRACK SuC- UNDERCUT REPAIR,