You are on page 1of 1
MAGNETIC PARTICLE INSPECTION = & REPORT No. 64 CLIENT CONTRACTOR LOCATION - _ | faeces SHEET 1 OF 1 —_ Engineering FERROSTAAL | SARIR OILFIELD i Construction Dept. | £CD462/2010 4 Taknia one aa sc REQUEST Ne, 4-22 (ECD) | MATERIAL ‘WELD PROCESS EQUIPMENT CONTACT SPACING Carbon Stee! GTAW Permanent Magnet 4~6cm. SIZE THICKNESS TYPE ‘CONTRAST PAINT V'dia. As per request | Magnaflux WCP-2 Magnaflux ‘SCHEDULE, PREPARATION | — SURFACE COND’t MAGNETIC INK AS BELOW Fillet Weld As welded 7HE Magnaflux LINE IDENTIFICATION ‘AREA 0-NGP321B.P1-A1-01 GC-4 DRAWING Ne. ‘ACCEPTANCE STD. WELD CLASS + ANS! 831.3 10% SPOOL / ITEM No. OPERATOR DATE N/A JV,REAE 03 AUGUST 2020 | wero |. WELD WLOR | pent, | DIA: | SCH. rasa PRED TYPE INTERPRETATION RESULT swa | 2” | 80 F10__[ 100% [FLANGE | NSD A | sw2 | 1” | c3000 | F10_ | 100% | PIPE NSD _A sw3 | 1” | 160 | F10 | 100% | ELBOW | NSD A swa | 1” | cso | F10_| 100% NIPPLE NSD la « = — > z *NOTHING FOLLOWS* | COMMENT / SKETCH \ COMPANY N AGOCO ‘AGOCO -Sarir NAME Rey Eduardo//” Abdul Hamed S, DESIGNATION (NDT |nspector XE.C.D,Dapt-Goordinator SIGNATURE BP DATE (03/AUGUST 2020 0g hucust 2020 LEGEND: NSD NO SIGNIFICANT D PG-POROSTY LF LACK OF FUSION A-accePreD NSD. NO REJECTABLE SIGNIFICANT DEFECT CK CRACK ‘SUG- UNDERCUT REPAIR