You are on page 1of 1
RSD. NOR MAGN TICLE AG. ETIC PARTICLE INSPECTION | REPORT No. 08 CLIENT CONTRACTOR LOCATION ~~ AGOCO FERPORTAAL | Engineering 7 ae SARIR OILFIELD — i Construction Dept. | £CD462/2010 Taknia anstruction Dep! 62/: REQUEST Ne, 1-22 (E.C.D) MATERIAL WELD PROCESS EQUIPMENT ‘CONTACT SPACING Carbon Steel GTAW Permanent Magnet 4~6cm, SIZE | THICKNESS TYPE CONTRAST PAINT 3/40 Sch.80 Magnaflux WeP-2 Magnaflux SCHEDULE PREPARATION SURFACE COND’N. MAGNETIC INK Standard Fillet Weld As welded THE Magnaflux LINE IDENTIFICATION ‘AREA 10” NG-40002-A1 GC3 DRAWING Ne. ‘ACCEPTANCE STD. WELD CLASS N/A ANSI B31.3 10% SPOOL / ITEM Ne. OPERATOR DATE WA WVREAE 03 APRIL 2020 7 WELD wor | WELD ; , wv ipenr, |M- | SCH Raia bees PE INTERPRETATION RESULT swes | 3/4” | 80 F10 | 100% | NIPOLET NSD A swe7| 3/4” | 80 | Fi0 | 100% | FLANGE NSD - A & al > *NOTHING FOLLOWS* | | COMMENT / SKETCH : COMPANY TAKNIA, ‘AGOCO AGOCO -Sarir NAME Rey Eduardo Lic ko Ahirozel Hadad DESIGNATION (BID inspgetor \ucgk Gy | “Ec. bept. Cgordifator SIGNATURE (EET. TABS DATE April 2020 «Gs %OLO 04 April2020 LEGEND: NSD- NO SIGNIFICANT DEFECT PG-poROSITY _LF~ LACK OF FUSION A-AccePTED {JECTABLE SIGNIFICANT DEFECT CK ~ CRACK sUC- UNDERCUT ne Repain