| - MAGNETIC PARTICLE INSPECTI9) REPORT NSTA7 = (co) um CLIENT, CONTRACTOR LOCATION ‘AGOCO mm mt mm | Engineering FERROSTAAL | sarinoitrte.n |SMET 1 OF 1 Taknia | Construction Dept. | £CD462/2010 GC-2 CEST, AA (E.C.0) MATERIAL WELD PROCESS EQUIPMENT CONTACT SPACING Carbon Steel GTAW Permanent Magnet 4~6em. SIZE THICKNESS TYPE CONTRAST PAINT v 5.69mm Magnoflux WCP-2 Magnaflux ‘SCHEDULE PREPARATION ‘SURFACE COND’N. MAGNETIC INK Sch.CL3000 Fillet Weld As welded 7HE Magnofiux LINE IDENTIFICATION "AREA 0-NG-P329A.P1-A1-01 GC-2 DRAWING Ne. ‘ACCEPTANCE STD. WELD CLASS 2385-NM-1350-102 ANSI 831.3 10% SPOOL / ITEM Ne. ‘OPERATOR DATE N/A VRE AE 22 JULY 2020 WELD wior | WELD Dent, | DIA: | SCH. ROR | AREA TYPE INTERPRETATION RESULT sw2 | 2” | ci3o00| Foi | 100% | ELBOW NSD A + = > | NOTHING FOLLOWS* [= COMMENT / SKETCH COMPANY AGOCO ‘AGOCO -Sarir NAME Abdul Hamed S, DESIGNATION ESD Dept. coordinator SIGNATURE DATE “JULY 2020 << yosuLy 2020 No SIGNIFICANT DEFECT PG-POROSIY LP LACK OF FUSION A ~AccEPTED NO REJECTABLE SIGNIFICANT DEFECT CK ~ CRACK SUC- UNDERCUT He REPAIR