You are on page 1of 1
———— Oo 0 MAGNETIC PARTICLE INSPECTION | REPORT Ne, 58 wD = CLIENT | CONTRACTOR LOCATION - ‘AGOCO wert 4 Engineering FERROSTAAL | sariR OILFIELD as Construction Dept. | £CD462/201 mi Taknia ‘onstruction Dept (CD462/2010 6c-4 (ear 0 (E.C.0) MATERIAL ‘WELD PROCESS EQUIPMENT CONTACT SPACING Carbon Steel GTAW Permanent Magnet _ | 4~6.m. SIZE | ‘THICKNESS TYPE CONTRAST PAINT r'dia. 5.69MM. Magnaflux WCP-2 Magnaflux ‘SCHEDULE PREPARATION SURFACE COND'N. MAGNETIC INK AS BELOW Fillet Weld l As welded 7HF Magnoflux LINE IDENTIFICATION ‘AREA 1-NG-30019-A1-HC . : ,GC-4 DRAWING No. ‘ACCEPTANCE STD. WELD CLASS ANS! 831.3 10% ‘SPOOL / ITEM No. ‘OPERATOR DATE N/A JV,REAE 03 AUGUST 2020 WELD WLOR | WELD pent, | DIA | SCH. aan ener TYPE INTERPRETATION RESULT swas | 1” [c13000 | Fo1 | 100% | ELBOW NSD) [A swi79| 1” | ci3000| Foi | 100% | ELBOW NSD [LA |< = t ea *NOTHING FOLLOWS* F ~ 7 aa _ _ COMMENT / SKETCH: COMPANY ‘AGOCO, AGOCO -Sarir NAME _ “Rey. Eduardo. ‘Abdul Hamed S, DESIGNATION Aiprinspedar SE.CP Dept Goordinator SIGNATURE | ( “7 ID DATE (03 AUGUST 2020 (_\03 AuGust 2020 LEGEND: NSD NO SIGNIFICANT DEFECT PG-POROSTY LP LACK OF FUSION A-ACCEPTED [NIISD- NO REJECTABLE SIGNIFICANT DEFECT CK ~ CRACK suc REPAIR