You are on page 1of 1
a 4 MAGNETIC PARTICLE INSPECTIO! REPORT Ne. 45 = 2 ue CLIENT CONTRACTOR LOCATION Agoco SHEET 1 OF 1 sana Engineering | FERROSTAAL | ‘saRiR OILFIELD Taknia Construction Dept. ECD462/2010 GC-2 aes (E.C.D) MATERIAL WELD PROCESS EQUIPMENT CONTACT SPACING Carbon Steel GTAW Permanent Magnet 4~6cm. SIZE THICKNESS TYPE CONTRAST PAINT fe 5.69mm & 3.38 mm Magnaflux WCP-2 Magnaflux SCHEDULE PREPARATION SURFACE COND’N. MAGNETIC INK Sch.CL300 & Sch.40 Fillet Weld As welded 7HF Magnoflux LINE IDENTIFICATION AREA 1-NG-40026.2-A1 GC-2 DRAWING Ne. ACCEPTANCE STD. WELD CLASS 2385-NM-1350-102, ANS! 831.3 10% ‘SPOOL / ITEM Neo. OPERATOR DATE N/A IV,RE AE 22 JULY 2020 WELD WLDR | WELD IDENT. DIA. | SCH. naa AREA TYPE INTERPRETATION RESULT sw 121] 1” | C3000 F10 100% ELBOW NSD A swi66 | 1” 40 F10 100% PIPE _ _ NSD A < — > *NOTHING FOLLOWS* ee if ‘COMMENT / SKETCH : COMPANY STAKNIA ‘AGOCO ‘AGOCO -Sarir [NAME (Rey Eduardo: Abdul Hamed S, DESIGNATION. “WDTinispegtor, ESD Dapt Coordinator SIGNATURE CERES ee Fi DATE JULY 2620 JULY 2020 LEGEND: NSB NO SIGNIFICANT DEFECT PG—POROSITY LF LACK OF FUSION A-AccEPrED NSD. NO REIECTABLE SIGNIFICANT DEFECT CK — CRACK. SUC- UNDERCUT H-REPAIR