MAGNETIC PARTICLE INSPECTION = = REPORT Ne. 40 - = CLIENT _ CONTRACTOR LOCATION itil agoeo SHEET 1 OF 1 2 Engineering FERROSTAAL SARIR OILFIELD |" i Construction Dept. | ECD462/2010 Taknia | Construction Dep 2/20 Gs REQUEST No. 1-22 (6.0) MATERIAL ‘WELD PROCESS EQUIPMENT | CONTACT SPACING Carbon Steel GTAW Permanent Magnet 4~6cm. SIZE THICKNESS TYPE ‘CONTRAST PAINT 3/4" 4.90mm Magnoflux WCP-2 Magnaflux ‘SCHEDULE PREPARATION SURFACE COND'N. MAGNETIC INK Sch.80 Fillet Weld As welded 7HE Mognafiux LINE IDENTIFICATION AREA 12-NG40002-A1-HC GC-2 DRAWING Ne. ‘ACCEPTANCE STD. WELD CLASS 2385-NM-1350-102 ANS! B31.3 10% SPOOL / ITEM No, OPERATOR DATE N/A IV,REAE 22 JULY 2020 WELD wir | WELD | . pent, {DIA |scH. | APR | Rea TYPE INTERPRETATION RESULT sw7i | 3/4” | 80 Fio | 100% | _ NIPOLET NSD A |< => *NOTHING FOLLOWS* ‘COMMENT / SKETCH : COMPANY ‘AGOCO, AGOCO -Sarir NAME ‘Abdul Hamed S, DESIGNATION NDT Inspector E.8.D Dent, Goprdinator. SIGNATURE zi DATE JULY 2020 : 1 jULY 2020 LEGEND: NSD NO SIGNIFICANT DEFECT PG=POROSITY LF LACK OF FUSION AccerreD [NIRSD- NO REJECTABLE SIGNIFICANT DEFECT CK CRACK Suc- UNDERCUT REPAIR