You are on page 1of 22

3000 MTPD AMMONIA

CALCULATION REPORT: UNIT 1710


17-EQ-020V
CONCRETE STRUCTURE CALCULATION REPORT

PROJECT : AMMONIA AND UREA PRODUCTION, KINGISEPP

SITE : KINGISEPP RUSSIAN FEDERATION

OWNER : LLC “EUROCHEM NORTHWEST-2”

TCM JOB No : 4124

TCM DOC. NUMBER : 4124-AA-CS-21710V020S01

P. Nair
01 Issue for Information 03-12-2021 G.Gargaglione G.Girardi
D. Pushkar
Rev. Description Date Prepared Checked Approved

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 1 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

INDEX

1. SCOPE ........................................................................................................................... 3
2. REFERENCE DOCUMENTS .......................................................................................... 3
3. PROJECT SPECIFICATION ANDSTANDARDS ............................................................ 3
4. SOFTWARE ................................................................................................................... 3
5. UNIT OF MESUREMENTREFERENCE DOCUMENTS .................................................. 3
6. SITE CONDITIONS ........................................................................................................ 4
7. FOUNDATION ................................................................................................................ 5
8. LOADS ON FOUNDATIONS .......................................................................................... 8
9. LOAD COMBINATIONS ................................................................................................. 9
10. FOUNDATION OF “EQPT. 17-V-020” ......................................................................... 10
11. ANNEXURE - I.............................................................................................................. 22

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 2 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

1. SCOPE
This calculation report contains the design of foundation for the LP condensate flash drum 17-V-
020. The design checks shown in this report is only for the concrete.

2. REFERENCE DOCUMENTS
Document Number Document Title
4124-AA-DX-200000001 General notes for Concrete Works
4124-AA-DX-200000002 Standard detail of anchor bolts
Technical specifications EQPT N°: 17-V-020 LP condensate
4124-CE-DX-21700E171
flash drum
Concrete drawing FW details of foundation LP condensate
4124-AA-DC-21710V020S01
flash drum 1710-EQ020V

3. PROJECT SPECIFICATION ANDSTANDARDS


Document Number Document Title
4124-AA-SG-200000001 General Specification for Concrete Works
4124-AX-SG-200000001 Structural Design Criteria for Steel & R.C. Structures

4. SOFTWARE
SAP 2000 (v21.0.2)
MAT3D (v6.5.0)
ARBAT (v21.1.9.9)
MS Excel

5. UNIT OF MESUREMENTREFERENCE DOCUMENTS


The SI unit will be used in design. In particular:

Length m, mm
Area m2
Mass Kg / ton
Concentrated force, weight N, kN
Linear distributed force kN/m
Moment of force kNm
Bearing Pressure / Surface distributed force kN/m2
Specific weight kN/m3
Pressure, stress N/mm2
Temperature / Change in temperature °C
Acceleration m/s2

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 3 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

6. SITE CONDITIONS

6.1 Water Table


Based on the observations mentioned in Geotechnical report, the Ground water level is
considered at BOF level which is referred to the level = +21.000m above average Baltic Sea
Level.

6.2 Frost Depth


As per Geotechnical & Environmental Interpretative Report (Doc. No. 4124-AX-SG-200000001),
frost depth considered is 1.50m below ground level.

6.3 Bearing Capacities


Bearing capacity, calculated in compliance with SP22.13330.2016 section 5.7, is provided in the
dedicated excel sheet for the three different level of the bottom of foundation and different
combinations of foundations size (BXL) and H/N values.

6.4 Settlement calculation


Net pressures corresponding to allowable settlements of 2.5 cm, 3 cm, 4 cm, 5 cm, calculated in
compliance with SP22.13330.2016 section 5.6, are provided in the dedicated excel sheet for three
different level of the bottom of foundation and different combinations of foundations sizes (BxL).

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 4 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

7. FOUNDATION

Foundation plan

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 5 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

Detail of foundation

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 6 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

Detail of Reinforcement

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 7 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

8. LOADS ON FOUNDATIONS
Below is the table of foundation loads for equipment 17-V-020, in accordance with doc. 4124-CD-
DX-21700V020:

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 8 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

9. LOAD COMBINATIONS

ULS COMBINATIONS

Long term
Permanent Short term temporaryloads. Special loads.
temporary loads.
Comb.

EQX1

EQY1
WX

WY
DO
DS

DE

BP
DT
ULS_01 0.9 0.9 0.9 1.4
ULS_02 0.9 0.9 0.9 1.4
ULS_03 1.05 1.05 1 1.4
ULS_04 1.05 1.05 1 1.4
ULS_05 0.9 0.9 0.8 1
ULS_06 0.9 0.9 0.8 1
ULS_07 0.9 0.9 0.8 1
ULS_08 0.9 0.9 0.8 1
ULS_09 0.9 0.9 1.12
ULS_10 0.9 0.9 1.12
ULS_11 1.05 1.05 1 0.98
ULS_12 1.05 1.05 1 0.98
ULS_13 0.9 0.9 1.2
ULS_14 1.05 1.05 1.2

SLS COMBINATIONS

Long term Short term temporary


Permanent
temporary loads loads
Comb.
W-X
WX
DO
DS

DE

SLS_01 1 1 1
SLS_02 1 1 1 1
SLS_03 1 1 1 1

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 9 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

10. FOUNDATION OF “EQPT. 17-V-020”

10.1 Geometry and input data

TITLE 2: 1710 - Subarea2 As per Equipment Layout Z

TOC EL = 100.250
Global Coordinate System

HPP EL = 100.000

NGL EL = 99.800 GW EL = 99.100 (Linked to "DATA FROM SGI ")

See NOTE

TOF EL = 98.600 (BOF EL + Thickness of Foundation)

Thickness of foundation = 0.600 m

Z BOF EL = 98.000
Vista longitudinale
See NOTE Longitudinal view
Y

BOF = Bottom of Foundation


EL = Elevation Size_Y2= 2.70 m Size_Y1= 3.50 m
GW = GroundWater
HPP = High Point of Pavement X X
NGL = Natural Ground Level
TOC = Top Of Concrete
TOF = Top Of Foundation

Size_X2= 2.70 m

Size_X1= 3.50 m
Y

2.4 Pedestal Dimensions

BCD(Bolt Circle Diamtere) of the eqpt = 2315 mm


Outer diameter of the anchor chair = 2375 mm
Dia of the anchor bolts = 24 mm ( 12 Nos.)
Width of pocket = 0 mm
Tension Capacity of Bolt = 45 kN

Face to face pedestal size should be maximum of following.


1) OD of the anchor chair + 2 x 50 = 2375 + 2x 50 = 2475 mm

2) BCD + 12 x dia of anchor bolts = 2315 + 12 x 24 = 2603 mm

3) BCD + Pocket width + (2 x 75) = 2315 + 0 + 2 x 75 = 2465 mm

Provide face to face of pedestal size, b as = 2603 mm say 2700 mm

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 10 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

GENERAL STRUCTURE INFORMATION

AREA AMMONIA
ITEM 1710 – Subarea2
DESCRIPTION -
LEVEL OF RESPONSIBILITY (I, II or III) II
SEISMICITY LEVEL ACCORDING TO
8
RICHTER SCALE
TYPE OF FOUNDATION Shallow foundation
REFERENCE CODE SP 22.13330.2011

GENERAL SOIL INFORMATION


FILL ABOVE FOUNDATION LEVEL -
18.00
SOIL UNT WEIGHT (kN/m3)
GROUNDWATER LEVEL (m below
0.90
HPP)

GEOTECHNICAL PARAMETERS FOR SLIDING VERIFICATIONS

Bottom Of Foundation (m HPP) 1.00 2.00 3.00


ID LAYER 1.1 1.1 1.1
Internal Friction Angle φI (°) 39 39 39 For static conditions
Δφ (°) FALSO
Internal Friction Angle φI-Δφ (°) 39.00 39.00 39.00 For seismic conditions

BASES ANALYSIS FOR BEARING CAPACITY AND SLIDING (ULS STATIC) – SP 22.13330.2011

FACTOR gC (-) 0.90

FACTOR gn (-) 1.15

Load on foundation

Case Vertical Seismic Wind


Load Shear Moment Shear "KN" Moment "KN-
"KN" "KN" "KN-m" m"
Equipment empty condition-EE 75 0 0 20 115

Weight equipment into operating 381 0 0 20 115


condition-EO

Equipment operating load - EO" 306 0 0 20 115

Equipment test condition-ET 397 0 0 7 37

Equipment Test load - ET" 322 0 0 7 37

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 11 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

10.2 Geotechnical checks

ULS - Bearing Capacity

REACTIONS FROM SAP2000 + FOUNDATION + BACKFILL


Hz (F3) Moment Moment Hx+Hy
Load Hx (F1) Hy (F2)
Limit State Vertical M1 M2 Horizonal ex ey
combinations Horizonal Horizonal
(ULS / SLS) load about X-dir about Y-dir load (m) (m)
Index (#) load (kN) load (kN)
(kN) (kN*m) (kN*m) (kN)
1 ULS 28.00 0.10 797.07 0.00 224.00 28.00 0.281 0.00
2 ULS 0.10 0.10 797.07 0.00 0.00 0.14 0.000 0.00
3 ULS 28.00 0.10 914.61 0.00 224.00 28.00 0.245 0.00
4 ULS 0.10 0.10 914.61 0.00 0.00 0.14 0.000 0.00
5 ULS - - - - - - - -
6 ULS - - - - - - - -
7 ULS - - - - - - - -
8 ULS - - - - - - - -
9 ULS 22.40 0.10 521.67 0.00 179.20 22.40 0.344 0.00
10 ULS 0.10 0.10 521.67 0.00 0.00 0.14 0.000 0.00
11 ULS 15.40 0.10 930.61 0.00 156.80 15.40 0.168 0.00
12 ULS 0.10 0.10 930.61 0.00 0.00 0.14 0.000 0.00
13 ULS 0.10 0.10 521.67 0.00 0.00 0.14 0.000 0.00
14 ULS 0.10 0.10 608.61 0.00 0.00 0.14 0.000 0.00
15 SLS - - - - - - - -
16 SLS - - - - - - - -
17 SLS - - - - - - - -

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 12 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

MACRO WORKING SPACE 7.95 116 920


B'
L' Meyerhof Average Check
Load min(L- L' / Bottom Of
max(L- H/N Pgross,ULS Area (B' soil for Soil PGROSS /
combinations 2ex;B- B' Foundation - -
2ex;B-2ey) (-) (kPa) * L') pressure Bearing PAVERAGE
Index (#) 2ey) (-) (m HPP)
(m) m2 kN/m2 Capacity
(m)
1 3.45 2.94 1.18 0.035 2.00 906.28 7.65 104.14 SAFE 8.70 - -
2 3.50 3.50 1.00 0.000 2.00 1015.24 9.61 82.93 SAFE 12.24 - -
3 3.46 3.01 1.15 0.031 2.00 920.37 7.90 115.72 SAFE 7.95 116 920
4 3.50 3.50 1.00 0.000 2.00 1015.29 9.61 95.16 SAFE 10.67 - -
5 - - - - - - - - - - - -
6 - - - - - - - - - - - -
7 - - - - - - - - - - - -
8 - - - - - - - - - - - -
9 3.43 2.81 1.22 0.043 2.00 881.86 7.22 72.22 SAFE 12.21 - -
10 3.50 3.50 1.00 0.000 2.00 1015.06 9.61 54.28 SAFE 18.70 - -
11 3.48 3.16 1.10 0.017 2.00 958.53 8.43 110.34 SAFE 8.69 - -
12 3.50 3.50 1.00 0.000 2.00 1015.29 9.61 96.83 SAFE 10.49 - -
13 3.50 3.50 1.00 0.000 2.00 1015.06 9.61 54.28 SAFE 18.70 - -
14 3.50 3.50 1.00 0.000 2.00 1015.14 9.61 63.32 SAFE 16.03 - -
15 - - - - - - - - - - - -
16 - - - - - - - - - - - -
17 - - - - - - - - - - - -

GROSS SOIL BEARING PRESSURE AT STATIC ULTIMATE LIMIT STATES (PGROSS_ULS)


H / N (-)
PGROSS,ULS (kPa) 0.000 0.050 0.075 0.100 -
L' / B' B' BOF (m from HPP)
(-) (m) 1.000 2.000 3.000 1.000 2.000 3.000 1.000 2.000 3.000 1.000 2.000 3.000 1.000 2.000 3.000
0.5 837 946 1 055 760 860 960 734 831 928 681 772 863 - - -
1.0 849 958 1 066 770 870 970 744 841 938 689 780 871 - - -
2.0 872 981 1 089 790 890 990 763 860 957 706 797 888 - - -
3.0 895 1 004 1 113 810 910 1 010 781 878 975 723 814 905 - - -
1.000
4.0 919 1 027 1 136 830 930 1 030 800 897 994 739 830 921 - - -
- 942 1 050 1 159 850 950 1 049 819 916 1 013 756 847 938 - - -
- - - -
- - - - - - - - - - - - - - - -

Maximum soil gross pressure 115.72 kPa < 920.37 kPa Checked

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 13 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

Overturning check

REACTIONS FROM SAP2000 + FOUNDATION + BACKFILL


Limit Restoring Restoring
Load Hz (F3) Moment M1 Moment M2
State moment about moment about
combinations Vertical load about X-dir about Y-dir
(ULS / X-dir Y-dir
Index (#) (kN) (kN*m) (kN*m)
SLS) (kN*m) (kN*m)
1 ULS 797.07 0.00 224.00 1394.86 1394.86
2 ULS 797.07 0.00 0.00 1394.86 1394.86
3 ULS 914.61 0.00 224.00 1600.57 1600.57
4 ULS 914.61 0.00 0.00 1600.57 1600.57
5 ULS 766.47 0.00 0.00 1341.31 1341.31
6 ULS 766.47 0.00 0.00 1341.31 1341.31
7 ULS 766.47 0.00 0.00 1341.31 1341.31
8 ULS 766.47 0.00 0.00 1341.31 1341.31
9 ULS 521.67 0.00 179.20 912.91 912.91
10 ULS 521.67 0.00 0.00 912.91 912.91
11 ULS 930.61 0.00 156.80 1628.57 1628.57
12 ULS 930.61 0.00 0.00 1628.57 1628.57
13 ULS 521.67 0.00 0.00 912.91 912.91
14 ULS 608.61 0.00 0.00 1065.07 1065.07
15 SLS - - - - -
16 SLS - - - - -
17 SLS - - - - -

ULS STATIC CONDITIONS ULS STATIC CONDITIONS


0.00 0.00 0 5.09 179.20 913
Check against Check against
Load
Ratio about overturning Ratio about Y overturning
combinations - - - -
X direction about X direction about Y
Index (#)
direction direction
1 - SAFE - - 6.23 SAFE - -
2 - SAFE - - - SAFE - -
3 - SAFE - - 7.15 SAFE - -
4 - SAFE - - - SAFE - -
5 - - - - - - - -
6 - - - - - - - -
7 - - - - - - - -
8 - - - - - - - -
9 - SAFE - - 5.09 SAFE 179.2 913
10 - SAFE - - - SAFE - -
11 - SAFE - - 10.39 SAFE - -
12 - SAFE - - - SAFE - -
13 - SAFE - - - SAFE - -
14 - SAFE - - - SAFE - -
15 - - - - - - - -
16 - - - - - - - -
17 - - - - - - - -

Minimum safety factor for overturning: 5.09 > 1 Checked

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 14 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

Sliding check

ULS STATIC CONDITIONS


REACTIONS FROM SAP2000 + FOUNDATION +
14.76 22 331
BACKFILL
Limit Combined
Load Hx (F1) Hy (F2) Hz (F3) Resistance Resistance
State Sliding
combinations Horizonal load Horizonal load Vertical load to sliding to sliding / Check - -
(ULS / force
Index (#) (kN) (kN) (kN) (kN) Sliding force
SLS) (kN)
1 ULS 28.00 0.10 797.07 28.00 505.14 18.04 SAFE - -
2 ULS 0.10 0.10 797.07 0.14 505.14 3571.85 SAFE - -
3 ULS 28.00 0.10 914.61 28.00 579.63 20.70 SAFE - -
4 ULS 0.10 0.10 914.61 0.14 579.63 4098.59 SAFE - -
5 ULS 0.10 0.10 766.47 0.14 - - - - -
6 ULS 0.10 0.10 766.47 0.14 - - - - -
7 ULS 0.10 0.10 766.47 0.14 - - - - -
8 ULS 0.10 0.10 766.47 0.14 - - - - -
9 ULS 22.40 0.10 521.67 22.40 330.60 14.76 SAFE 22 331
10 ULS 0.10 0.10 521.67 0.14 330.60 2337.71 SAFE - -
11 ULS 15.40 0.10 930.61 15.40 589.77 38.30 SAFE - -
12 ULS 0.10 0.10 930.61 0.14 589.77 4170.29 SAFE - -
13 ULS 0.10 0.10 521.67 0.14 330.60 2337.71 SAFE - -
14 ULS 0.10 0.10 608.61 0.14 385.70 2727.33 SAFE - -
15 SLS - - - - - - - - -
16 SLS - - - - - - - - -
17 SLS - - - - - - - - -

Minimum safety factor for sliding along y direction: 330.6 > 1 Checked
Minimum safety factor for sliding along x direction: 14.76 > 1 Checked

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 15 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

Serviceability limit states

REACTIONS FROM SAP2000 + FOUNDATION + BACKFILL


Horizontal Loads Vertical Load Moments
MACRO WORKING SPACE
(kN) (kN) (kN*m)
MB ML
eL eB
HL HB Hz (F3) along along L 2.50 3.50 3.50
(m) (m)
B dir. dir.
Load
M1 M2 Allowable
combination Limit State ey L B
Hx (F1) Hy (F2) Hz (F3) about about Settlement ex (m)
s (ULS / SLS) (m) (m) (m)
X-dir Y-dir (cm)
Index (#)
1 ULS - - - - - - - - - -
2 ULS - - - - - - - - - -
3 ULS - - - - - - - - - -
4 ULS - - - - - - - - - -
5 ULS - - - - - - - - - -
6 ULS - - - - - - - - - -
7 ULS - - - - - - - - - -
8 ULS - - - - - - - - - -
9 ULS - - - - - - - - - -
10 ULS - - - - - - - - - -
11 ULS - - - - - - - - - -
12 ULS - - - - - - - - - -
13 ULS - - - - - - - - - -
14 ULS - - - - - - - - - -
15 SLS 0.10 0.10 885.63 0.00 0.0 2.50 0.00 0.00 3.50 3.50
16 SLS 20.00 0.10 885.63 0.00 160.00 2.50 0.18 0.00 3.50 3.50
17 SLS 0.10 0.10 885.63 0.00 0.00 2.50 0.00 0.00 3.50 3.50

CHECK FOR MIN { Psettlement ; R }


1.00 2.00 10.14 333.92 6.08 55 334
Load Bottom Of
L/B A PNET,AVERAGE Pnet,SLS Check for Pnet /
combinations Foundation - -
(-) (m2) (kPa) (kPa) Settlements Paverage
Index (#) (m HPP)
1 - - - - - - - - -
2 - - - - - - - - -
3 - - - - - - - - -
4 - - - - - - - - -
5 - - - - - - - - -
6 - - - - - - - - -
7 - - - - - - - - -
8 - - - - - - - - -
9 - - - - - - - - -
10 - - - - - - - - -
11 - - - - - - - - -
12 - - - - - - - - -
13 - - - - - - - - -
14 - - - - - - - - -
15 1.00 2.00 10.14 54.96 333.92 SAFE 6.08 55 -
16 1.00 2.00 10.14 54.96 333.92 SAFE 6.08 55 -
17 1.00 2.00 10.14 54.96 333.92 SAFE 6.08 55 334

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 16 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

MACRO
WORKING CHECK FOR Pmax
4.21 =Z of
348.66 inscribed SPACE 3.34 125 523
circle
Checks
Load P_Max_edge P_Max_edge P_Max_  P_Max_ for
RGROSS Pcorner
combinations along Y along X corner (from corner Pedge - -
(kPa) / Pmax
Index (#) (kPa) (kPa) (kPa) table) (kPa) &
Pcorner
1 - - - - - - - - - -
2 - - - - - - - - - -
3 - - - - - - - - - -
4 - - - - - - - - - -
5 - - - - - - - - - -
6 - - - - - - - - - -
7 - - - - - - - - - -
8 - - - - - - - - - -
9 - - - - - - - - - -
10 - - - - - - - - - -
11 - - - - - - - - - -
12 - - - - - - - - - -
13 - - - - - - - - - -
14 - - - - - - - - - -
15 348.66 87.36 87.36 87.36 - 87.36 SAFE 4.79 - -
16 348.66 87.36 125.37 125.4 - 125.4 SAFE 3.34 125 523
17 348.66 87.36 87.36 87.36 - 87.36 SAFE 4.79 - -

Settlement check:

Maximum soil net pressure: 125.37 kPa < 348.66 kPa Checked

NET SOIL BEARING PRESSURE AT SERVICEABILITY LIMIT STATES (PNET_SLS)


SETTLEMENTS (cm)
PNET,SLS (kPa) 2.500 3.000 4.000 5.000 -
L/B B BOF (m from HPP)
(-) (m) 1.000 2.000 3.000 1.000 2.000 3.000 1.000 2.000 3.000 1.000 2.000 3.000 1.000 2.000 3.000
0.5 318 339 361 318 339 361 318 339 361 318 339 361 318 339 361
1.0 322 343 365 322 343 365 322 343 365 322 343 365 322 343 365
2.0 329 351 373 329 351 373 329 351 373 329 351 373 329 351 373
3.0 337 359 380 337 359 380 337 359 380 337 359 380 337 359 380
1.000
4.0 332 309 283 345 366 336 345 366 388 345 366 388 332 309 283
5.0 238 226 212 283 268 252 352 353 332 352 374 396 238 226 212
6.0 - - - - - - - - - - - - - -
7.0 - - - - - - - - - - - - - - -

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 17 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

10.3 Pedestal checks


The pedestal checks of equipment 17-V-020 are show below:

Section 3D Model

Summary

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 18 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

Flexure details

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 19 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

10.4 Anchor bolts checks

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 20 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 21 of 22
Document Title TCM Document No. Rev.
17-EQ-020V
4124-AA-CS-21710V020S01 01
CONCRETE STRUCTURE CALCULATION REPORT

11. ANNEXURE - I
Calculation backup files

This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used by any
party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality label, if any.

Page 22 of 22