You are on page 1of 1

TEST REPORT

Name of Applicant: M/s: KCM APPLIANCES PVT LTD


CM/L: 6200141888
Address of Applicant/Licensee: No 266-P & 267P, Sy No. 95 P, Karadubande, Hosahalli, Village, & 134, Achatanahalli Village,
Narasapura , Kolar, KOLAR, KARNATAKA, INDIA - 562105

IS: 2347:2017
Product: Domestic pressure cooker
Grade/Type/Variety/Class: Domestic Pressure Cookers, Outer Lid Type, Al. body & Lid, Nominal cooking steam Pressure
1.0 kgf/cm2.
Declared values, if any: 2.5ltr ,3.5ltr, 4.5ltr Non induction base

Any other information: Nil


Date of start of testing: 28.09.2023 Date of completion of testing: 30.09.2023

Sr. Tests Clause IS Specified Requirement 2.5ltr 3.5ltr 4.5ltr Remarks


No. Reference
1 Capacity test 4.1 2347:2017 No negative tolerances shall be 2.6ltr 3.52ltr 4.6ltr Pass
allowed on the nominal capacity.
2 Diameter of vent 6.1.1 2347:2017 Minimum inside diameter of vent 2.79mm 2.81mm 2.7mm Pass
pipe pipe shall be 2.5 mm.
3 Air pressure test 8.1 2347:2017 Cooker shall not show any sign of No leakage No leakage No leakage Pass
leakage or deformation at nominal found found found
cooking pressure
4 Proof pressure test 8.2 Annex 2347:2017 Cooker shall not show any sign of No leakage No leakage No leakage Pass
F leakage or other forms of failure found found found
either during or after the test at twice
the nominal cooking pressure
5 Operating pressure 8.3, Annex 2347:2017 The pressure regulating device shall 1.1 kgf/cm2 1.0kgf/cm2 1.05kgf/cm2 Pass
test pressure G operate within t 20 percent of the
regulating device nominal cooking steam pressure as
declared by the manufacturer. T
6 Test for Safety 8.4 2347:2017 Safety pressure relief device should Resettable: Resettable: Resettable: Pass
pressure relief Annex H operate between 1.5kgf/cm2 to 1.9kg/cm2 2.1kgf/cm2 2.1kg/cm2
device and G 3.0kgf/cm2 Destructible: Destructible: Destructible:
2.4kg/cm2 2.5kg/cm2 2.4kg/cm2
7 Bursting pressure 8.5 2347:2017 The bursting pressure of the cooker Withstood Withstood Withstood Pass
test Annex J shall not be less than 6 kgf/cm2.

8 Test for removal of 8.6.1 2347:2017 The cooker should not open until the Not opened Not opened Not opened Pass
lid under pressure Annex K pressure inside has fallen below 0. I
8 kgf/cm2.

The above-mentioned sample manufactured and tested at our premises is conforming/non-conforming


to the requirement(s) of IS 2347:2017

Signature

Name: Mallesh

Designation: Assistant manager QA

Seal of Firm Date:18.10.2023