top frame.

As shown in Fig. 16, the discharge size will increase when turning the cap frame counter-clockwise, and the
discharge size will decrease when turning the cap frame clockwise. After adjustment, lock the hydraulic
cylinder and add oil pressure, tighten the top cell and the concave totally.

Hydraulic
Motor incl. Spherical Gear
Gear Reducer
Hydraulic Locking Cylinder

Figure No. 16 - Adjust the Discharge Setting

9 OPERATION

9.1 Drive Rotation Direction

When facing the V-Belt Sheave, always rotate the pulley clockwise. This rotation tends to fasten the
Mantle. Rotating the sheave counter-clockwise tends to loosen the Mantle.

23