Operation and Daily


Service Manual

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 1


Recognize the Resistance Numerical

Normally Sign Arithmetic Reality Number

100 10*1 10Ω


201 20*10 200Ω
1000 100*1 100Ω
4701 470*10 4.7KΩ
5R1 5R1=5.1 5.1Ω
51R 51R=51 51Ω
R220 R220=0.22 0.22Ω
R150 R150=0.15 0.15Ω

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 2


Method of Testing the Dio

Mutimeter Dio Pipeline


正极 负极

Red Side Black Side Number

Anode + Cathode- 0.4~0.5

Anode +
Cathode- 0.6~0.9

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 3


Testing of 桥堆

Multimeter in Dio

Black bar
Red bar
testing Multimeter
testing
position Record
position

3 branch 0.4~0.5

4 branch
2 Branch 0.4~0.5

1Branch 0.4~0.5

2 branch 0.4~0.5
1Branch

3 branch 0.4~0.5

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 4


Testing of IGBT

To use the resister level of multimeter test the PCB

Red Bar Black Bar Multimeter Record

2 branch 0.4~0.5

1 branch

3 branch 0.6~0.7

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 5


Testing IRF530

The main PCB no power, the multimeter


record in dio

Red Bar Black Bar Multimeter


Position Position Record

2 branch 0.4~0.5

1 Branch

3 branch 0.6~0.9

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 6


芯片的测量( 2272 )

With poer, the multimeter in DC

Red bar Black bar Multimeter record

标记点

1 branch 1.25V or 1.65V

7 branch 4branch 1.25V or 1.65V

8 branch 3.3V or 5V

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 7


1000 PCB

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 8


Err-01 故障维修
To check the PCB Y Change the Y
Testi
weather have broken broken ng
parts parts
N
N

With electricity, to use


DC level 20V test C15 Change the
Y Y
the power is 15V or the Testi
broken
Voltage is lower ng
parts

N
N

TO USE THE Dio level


test the Y Change the Y
Testi
Q10Q13Q11Q14Q12Q1 broken ng
5 Q61 damage or not parts
N
N

To use resistor level test


R83 R84 R73 R74 R80 Y Change the Y
Testi
R82 damage or not broken
ng
parts
N
N

Change the CT1 CT2 Y Change the Y


Testi
U3 broken ng
parts
N

Back to PASS
Jack
factory
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 9
2136

电流传感器
IGBT

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 10


Err-03 、 04 、 05 故障维修
To check the PCB have Y Change the Y
obvious broken parts broken test
parts ing
N
N

To use the Dio level in


multimeter test Y Change the Y

D36D37D38D39D40D4 broken test


1D43D42 damage or parts ing
not

N
N

To use the resister level


of multimeter test
R252R233R253R272R2
34R235R236R237R238
R239R240R241R242R2 Y Change the Y

43R244R245R246R247 broken tes


R248R249R250R251R2 parts tin
54R255R256R257R256 g
R258R259R260R261R2
62R263R264R264R267
R268R269R270R271ok
or not

N
N

Y Change the Y
Exchange U23 broken test
parts ing

Send PASS
back to
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 11
factory
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 12
Err-06 故障维修
To check the PCB have Y Change the Y
test
obvious broken parts broken
ing
parts
N

To use the Dio level test


R88R93R99R91R100R Y Change the Y

102R98R89R92R94R95 broken test


R96R97R101R85R88R parts ing
87 damage or not

To use the resister level


D15D21Q19Q16Q17D1
0D12D14D17D18D8D9
D11D13D16Q18Q27TC Y
Change the Y

1Q29Q36Q35D19D20D broken test


21D22D24D23 damage parts ing
or not

Y
Change the Y
Change the U15 broken test
parts ing

Send PASS
back to
the
factory
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 13
IRF530

2272

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 14


Err-07 故障维修
To check the PCB have Y
Change the Y

obvious broken parts broken test


parts ing

N
N

To use the Voltage DC level to test


U21 the branch 1 and 4 to show the
Voltage near 1.65 , the branch 4 and
7 Voltage near 1.65v. branch 4 and 8
voltage near 3.3v. To test U11 the
branch 1 and 4 Voltage near 2.5V , the Y Change the Y
branch 4 and 8 near 5V. If all these ok. broken test
Again check the C59 and C60, the ing
parts
both side voltage near 2V, if not show
2v,means the CT1,CT2already broken.

N N

To use the resister level


of multimeter test
R179R187R173R180R1
Y
74R176R183R185R175 Y Change the
R177R184R186R175R1 broken test
77R184R186R42R48R5 parts ing
0R53R56R51R54damag
e or not
N

Send PASS
项目名称 | 日期
back to
PROJECT NAME | date CONFIDENTIAL 15
the
factory
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 16
Err-08 故障维修
To check the PCB have Y Change the Y
obvious broken parts broken test
parts ing
N
N

•To use the Voltage DC


level test C15 the both side Y Change the Y
is 15V. if not 15V, check test
broken
U28 the 2 branch and 3
parts ing
branch the voltage should
be 15V unless its broken.

N
N

•To use the Dio level in multimeter


test Q10 Q11Q12Q13Q14Q15, all
to check all the branch 1 and 2 has Y Change the Y

near 0.45 voltage drop branch 1 broken test


and 3 has 0.68 , if its straight or parts ing
drop voltage, it means broken.

N
N

To use the resister level Y Change the Y


of multimeter test broken test
R3R6R13R16R20R24d ing
parts
amage or not
N
N

Y Change the Y
test
change U3 broken
ing
U17 parts
N

Send PASS
back to
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 17
the
factory
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 18
Err-09 故障维修

To check the PCB Y Change the Y


weather have broken broken test
parts parts ing
N
N

To use the Dio level in Y Change the Y


multimeter test test
D35D47D210 broken
parts ing
Q48Q49U22 damage or
not
N
N

To use the resister level Change the Y


Y
of multimeter test test
broken
R231R232 R230 R234 ing
—R251 R2damage or parts
not
N
N

Change the
更换 U23 Y
test
Y
broken
parts ing
N

Send PASS
back to
the
factory

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 19


PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 20
Err-10 故障维修
Y
To check the PCB Change the Y
weather have broken broken test
parts parts ing
N
N

•To use the Voltage DC


20V level test C33 both
side 5V is ok or not, if
not normal, check C123
Y Change the Y

both side have 5V, C43 broken test


both side 3.3V is normal parts ing
or not. if not, change
U13.

To use the resister level Y Change the Y


of multimeter test L11 broken test
L12 R57 parts ing
R58R60damage or not

Y Change the Y
To use the Dio level in test
multimeter test broken
parts ing
D7damage or not
, change u18

Send PASS
back to
the
factory

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 21


PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 22
Err-11 故障维修
Y
To check the PCB Change the Y
weather have broken broken test
parts parts ing
N
N

To use the resister level


of multimeter test Y Change the Y
L28L29L30L31L25L26 broken test
R160R161R151R152R1 parts ing
44R145damage or not

To use the Dio level in Y Change the Y


multimeter test broken test
D28D27damage or not parts ing

N
N

Y Change the Y
Change u16 test
broken
parts ing

Send PASS
back to
the
factory

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 23


PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 24
Err-13 故障维修
Y
To check the PCB Change the Y
weather have broken broken test
parts parts ing
N

To use the resister level


of multimeter test
L20L22L24R153R154R Y Change the Y
155R142R143R144R14 broken test
5R146R147R148damag ing
parts
e or not

To use the Dio level in Y Change the Y


multimeter test broken test
D29D30D31damage or parts ing
not
N
N

Y Change the Y
Change U16 test
broken
parts ing

Send PASS
back to
the
factory

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 25


PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 26
无电源故障
Y
To check the PCB Change the Y

weather have broken broken test


parts parts ing
N
N

To use the Dio level in Y


Y Change the
multimeter test test
FUS1FUS2L33L34DB1
broken
parts ing
damage or not
N
N

Y
To use the resister level Y
of multimeter test Change the
broken test
R315R316R138R317R3
18R319R320damage or parts ing
not

To use the Dio level in Y


Change the Y
multimeter test U30 broken test
U31 damage or not ing
, change transformer
parts
N
N

更换 U29 Y
Change the Y

broken test
parts ing
N

Send PASS
back to
the
factory
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 27
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 28
2000PCB

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 29


Err-01 故障维
修 To check the PCB Y Change the Y
weather have broken broken test
parts parts ing
N

•To test C89 has 15V, Y Change the N Y

weather the Voltage is too broken test


much lower. If lower please parts ing
change U21.
N

To use the Dio level in Y


multimeter test Change the Y

broken test
Q17Q18Q19Q21Q23Q2
4 to test the parts ing
6IGBTdamage or not N
N

To use the Resister level and


Dio level in multimeter test Y Change the Y
R211R121R213 broken test
D21D22D23damage or not parts ing

N
N

Change
TVS1R111R144R153R15 Y

6 test
ing

N
N

更换 U29
Y

test
ing
N

Send PASS
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 30
back to
the
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 31
Err-04 故障维修

Y
To check the PCB Change the Y
weather have broken broken test
parts parts ing
N
N

To use the resister level Y Change the Y


of multimeter test R11 、 broken test
R16damage or not parts ing
N

Send PASS
back to
the
factory

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 32


PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 33
Err-06 故障维修

Y
To check the PCB Change the Y
weather have broken broken test
parts parts ing
N

To use the Dio level in Y Change the Y


multimeter test
broken test
Q22Q10Q12Q16Q15Q9
damage or not parts ing
N

To use the Dio level in


multimeter test D11 Y Change the Y
D12D13D17D2D45dam broken test
age or not parts ing

Send PASS
back to
the
factory

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 34


To control To control pressure
To control To control back stitch foot lifting
To control the To control
wipe The wipe
electromagnet trimming
thread thread

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 35


Err-07 故障维修

Y
To check the PCB Change the Y
weather have broken broken test
parts parts ing
N
N

•To use the up Voltage DC


level 20V test U20 the
branch 4 and 8 weather Y Change the Y
near 3.3V. Branch 1 and broken test
4 , 4 and 7 has 1.65V. If ing
parts
not, please change (R150
R151 U20)

Send PASS
back to
the
factory

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 36


PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 37
Err-08 Breakdown maintenance
Inspect the electronic components on the
power panel by eye,finding whether there
is some damage obviously
Y
Repalce the Y
bad parts Test
N

Use DC Voltage 220V gear to measure Y Repalce the Y


the both ends of C89 to check whether bad parts Tes
there is 15 V.If not ,then check whether t
U21 is damaged or not
N

Use diode gear to measure Y Repalce the Y


Q17Q18Q19Q21, Q23Q24 whether bad parts Tes
they are damaged t

N
N

Use diode gear and resistance gear to Y Repalce the Y


measure TVS2 TVS3 R150 R151 whether bad parts Test
they are damaged

N
N

Y
Check the plug of CN10 whether it is Repalce the Y

damaged and replace U17 bad parts Test

Return to PASS
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL factory and 38
repair
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 39
Err-09 Breakdown maintenance

Inspect the electronic


components on the power panel
by eye,finding whether there is Y
Repalce the Y
some damage obviously bad parts Test

N
N

Y Repalce the Y
Test
Check Q4 whether it is bad parts
damaged

N
N

Use diode gear to measure Tes


Q1Q2Q3 D3 Z2 Z3 whether
t
they are damaged

Return to PASS
factory and
repair

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 40


PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 41
Err-10Breakdown maintenance
Y
Inspect the electronic components on Repalce the Y
the power panel by eye,finding whether bad parts Test
there is some damage obviously
N
N

Use voltage gear to measure the 1st and 3rd


food of U26,finding it whether has 5 Y Repalce the Y
voltage.If not,replace U27.If has,then
bad parts Test
measure the 1st and 2nd foot of U26,finding
it whether has 3.3 voltage,if not,repalce
U26. N

Use diode gear to measure U12 Y Repalce the Y


U13U14,finding it whether is bad parts Test
damaged

N
N

Use resistance gear to measure Repalce the


Y Y
R98R115R104RR103R107R105R1 Test
bad parts
06R113 whether they are damaged

N
N

Y Y
If still show Err-10,then Test
change R113 to 2KΩ

Return to PASS

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL


factory 42
and repair
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 43
Err-11Breakdown maintenance
Inspect the electronic components on
the power panel by eye,finding Y
whether there is some damage Repalce the Y
bad parts Test
obviously

N
N

Use DC Voltage gear to measure Y Repalce the Y


the both ends of the C80,finding it bad parts Test
whather has 5 voltage.If not,check
U27.
N
N

Use resistance gear to measure CN7 Y Repalce the Y


R78 R97 L14 R118 to find out whether bad parts Test
it is damaged

N
N

Use diode gear to measure U15 to Y Repalce the Y


find out whether it is damaged bad parts Test

Replace U6 Y Repalce the Y


bad parts Test

PASS
Return to
factory and
repair

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 44


PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 45
Err-13Breakdown maintenance

Inspect the electronic


components on the power
panel by eye,finding whether Y
there is some damage Repalce the Y

obviously bad parts Test

N
N

Use resistance gear to measure L7


R50R51R75R76R77R78 Y Repalce the Y
R94R95R96R97R79R80 to find out bad parts Test
whether they are damaged or not

Y Repalce the Y
Replace U6 bad parts Test

Return to PASS
factory and
repair

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 46


PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 47
AHE58

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 48


Power Panel

Electromagnet control

HMI 5V 输出

Presser foot Sweep line BackstitchThread wipeThread trimmer

Switching power supply

15V Output 5V Input

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 49


Control Panel

Rectifier filter

Driving control

Master chip

3.3V Output

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 50


AHE58 Circuit Board Distinguishing

Power Panel Control Panel

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 51


Err-01 Breakdown Maintenance
Use diode gear to measure C8 and C9 on the
Y
Replace the Y
power panel to find out whether they has bad parts Test
short circuit
N
N

On power-up state,measuer U10 to find out


whether it has 15 Voltage,if not or higher
Y Replace the Y
bad parts Test
or lower than 15V,then replace U10

N
N

Y Replace the Y
Use diode gear to measure Q17 Q18 Test
bad parts
Q19 Q21 Q23 Q24 on control panel to
find out whether some of them are
damaged

N
N

Use resistance gear and diode gear to


measure TVS3 R151 RTV2 R150 to Y
Replace the Y
fiind out whether they are damaged bad parts Test

N
N

Y
Replace U17
Test

Return to PASS
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 52
factory
Power Panel Control Panel

C9 IGBT

2136
U10

C8

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 53


Err-07 Breakdown Maintenance

Inspect the electronic


components on the power panel
by eye,finding whether there is Y
Replace the Y
some damage obviously bad parts Test

N
N

On power-up state,use DC voltage gear to


measure the 1st &4th foot ,and 4th &7th foot
of U20 to find out whether there is 1.65
voltage.If not,replace U20 Y Replace the Y
bad parts Test

Return to PASS
factory and
repair

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 54


2272

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 55


Err-08Breakdown Maintenance
Y
Use diode gear to measure C8,C9 to find out Replace the Y
whether they have short circuit bad parts Tes
t
N
N

Use DC voltage gear to


measure U10 to find oud
whether it has 15 voltage.If Y Replace the Y
not,check U10 whether it is bad parts Test
damaged

Use diode gear to measure


Q17Q18Q19Q21, Q23Q24 to find out Y Replace the Y
whether they are damaged bad parts Test

N
N

Use diode gear to measure D21 D22 D23 and Replace the
Y Y
resistance gear to measure R211 R212 R213 to find Test
bad parts
out whether they are damaged.

Return to PASS
factory and
repair

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 56


Power Panel Control Panel

IGBT

2136

U10

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 57


Err-09Breakdown Maintenance

Inspect the electronic


components on the power
Y
panel by eye,finding whether Replace the Y
there is some damage bad parts Test
obviously
N

Use diode gear to measure Q7D4 Y Replace the Y


Q9Q8Q11 D3 Z3Z4 to find out Test
whether they are damaged
bad parts

N
N

Use resistance gear to measure


R9R10RR14R16R 18R19 to find
Y Replace the Y

out whether they are damaged bad parts Test

Return to PASS
factory
and repair

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 58


IGBT

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 59


Err-10Breakdown Maintenance
Inspect the electronic
components on the power panel Y
Replace the Y
by eye,finding whether there is
bad parts Test
some damage obviously
N
N

Use voltage gear to measure


1st &3rd foot of U27 to find Replace the Y
Y
out whether it has 5 voltage bad parts Test
output.If not,replace U27

Use diode gear to measure U26


and D18 to find out whether Y Replace the Y
they are damaged. bad parts Test

N
N

Replace U2 and U6 Y
Test

Y
If still report Err-10,then replace the
panel pallet Tes
t

Return to PASS
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL
factory and 60
repair
Power panel Control panel

U2
U26
U11 U2

U27
U27

D18

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 61


Err-13Breakdown Maintenance

Inspect the electronic components on


Y
the power panel by eye,finding Replace the Y
whether there is some damage bad parts Test
obviously
N
N

Use resistance gear to measure R50


R51 R59 R79 to find out whether they Y Replace the Y
are damaged Test
bad parts

N
N

Replace U2 Y Y
Test

PASS PASS

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 62


Control panel

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 63


Breakdown maintenance for no trimming,no reverse
stitching,no presser foot movement
Inspect the electronic components
on the power panel by eye,finding Y
Replace the Y
whether there is some damage bad parts Test
obviously
N
N

Use diode gear to measure Q8 Q7 Q5 Q6


to find out whether they are damaged Y Replace the Y
Test
bad parts

N
N

Replace U7 U29 U3 accordingly Y Y


Test

PASS PASS

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 64


Presser foot lifter Backstitch Thread trimmer

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 65


A 4
Circuit Board Maintenance

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 66


Err- Inspect the electronic
components on the power
panel by eye,finding Y

01Breakdown
Replace the Y
whether there is some Tes
bad parts
damage obviously
t

Maintenance
N
N

On power-up state,use voltage


gear to measure C40 to find out
whether it has 15 voltage.If not
Y Replace the Y

or higher or lower than 15v ,then bad parts Test


replace U10

N
N

Use diode gear to measure


Q17Q18Q19Q21Q23Q24 to find Y Replace the Y

out whether they are damaged bad parts Test

N
N

Use resistance gear and diode


gear to measure TVS3 R151 Y
Replace the Y
RTV2 R150 to find out whether bad parts Test
they are damaged

N
N

Y
Replace U17
Test

Return to factory PASS


PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 67
and repair
Front side of circuit board Reverse side of circuit board

U10

IGBT

2136

R150 R151 TVS2 TVS3

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 68


Err-08Breakdown Maintenance
Inspect the electronic
components on the power
panel by eye,finding whether Y
Repalce the Y
there is some damage bad parts Test
obviously
N

Use DC voltage gear to measure


C40 to find out whether it has 15 Y Repalce the Y
voltage.If not,then check U10 bad parts Test
whether it is damaged

Use diode gear to measure


Q17Q18Q19Q21, Q23Q24 to find Y Repalce the Y
out whether they are damaged bad parts Test

N
N

Use diode gear to measure TVS2


TVS3 and use resistance gear to Y Repalce the Y
measure R150 and R151 to find out Tes
bad parts
whether they are damaged t

N
N

Y
Replace U17 Repalce the Y

bad parts Test

Return to PASS
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL factory and 69
repair
Front side of circuit board Reverse side of circuit board

U10

IGBT

2136

R150 R151 TVS2 TVS3

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 70


Err-10Breakdown Maintenance
Inspect the electronic
components on the power
Y
panel by eye,finding whether Replace the Y
there is some damage bad parts Test
obviously
N
N

Use voltage gear to measure the


1st&2nd foot of U24 to fiind out Replace the Y
Y
whether it has 5V output.If bad parts Tes
not,replace U24 t

Use diode gear to measure D16 to


find out whether it is damaged Y Replace the Y
bad parts Test

N
N

Measure R57 R82 to find out Y Replace the Y


whether their resistance value is bad parts Test
normal
N

Y
Replace U3 U11
Tes
t

Return to PASS
PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL
factory and 71
repair
Reverse side of circuit board Front side of circuit board

1 D16

U24

PROJECT NAME | date 项目名称 | 日期 CONFIDENTIAL 72