PROJECT : AFC BUKIT JALIL

EXISTING WCPU CONSTRUCTION


NOMINAL NOMINAL
CONDENSER WATER
CAPACITY AIRFLOW WATER CAPACITY AIRFLOW WATER FLOW
LEVEL TAG MODEL TYPE TAG TYPE TEMPERATURE REF. TYPE
(BTU/HR) (CFM) FLOW RATE (BTU/HR) (CFM) RATE
(INLET/ OUTLET)
(IGPM) (IGPM)
G-1 50PV125 WCPU 130000 4026 27.08 G-WCPU-1 WCPU - FLOOR MOUNTED 174012 4705 87°F/ 97°F 36.25
G-2 50PV125 WCPU 130000 4026 27.08
G-3 50PV125 WCPU 130000 4026 27.08 G-WCPU-2 WCPU - FLOOR MOUNTED 399204 11647 87°F/ 97°F 83.17
GROUND G-4 50PV090 WCPU 89750 3216 18.70
FLOOR G-5 50PV250 WCPU 253000 8095 52.71 G-WCPU-3 WCPU - FLOOR MOUNTED 247370 9800 87°F/ 97°F 51.54
G-6 50PV300 WCPU 300000 9472 62.50 G-WCPU-4 WCPU - FLOOR MOUNTED 324140 10000 87°F/ 97°F 67.53
G-FCU-1 50PH050 WCPU 46740 1354 9.74 G-WCPU-5 WCPU - HORIZONTAL 54592 1647 87°F/ 97°F 11.37
87°F/ 97°F R410A
G-FCU-2 50PH050 WCPU 46740 1354 9.74 G-WCPU-6 WCPU - HORIZONTAL 54592 1647 11.37
FIRST 1F-7 50PV200 WCPU 205000 6611 42.71 1F-WCPU-1 WCPU - FLOOR MOUNTED 247370 9800 87°F/ 97°F 51.54
FLOOR 1F-8 50PV250 WCPU 253000 8095 52.71 1F-WCPU-2 WCPU - FLOOR MOUNTED 247370 9800 87°F/ 97°F 51.54
2F-9 50PV250 WCPU 253000 8095 52.71
2F-WCPU-1 WCPU - FLOOR MOUNTED 528860 14471 87°F/ 97°F 110.18
SECOND 2F-10 50PV200 WCPU 205000 6611 42.71
FLOOR 2F-FCU-1 50PH060 WCPU 61720 1650 12.86 2F-WCPU-2 WCPU - HORIZONTAL 64828 2000 87°F/ 97°F 13.51
2F-FCU-2 50PH060 WCPU 61720 1650 12.86 2F-WCPU-3 WCPU - HORIZONTAL 64828 2000 87°F/ 97°F 13.51
TOTAL 451.18 igpm TOTAL 501.49 igpm

Note :
Existing Condenser Pump Capacity 534 IGPM @ 90 ft head