Professional Documents
Culture Documents
Pvsyst Trial Pvsyst Trial Pvsyst Trial Pvsyst Trial
Pvsyst Trial Pvsyst Trial Pvsyst Trial Pvsyst Trial
PVsyst TRIAL
Project: romorque solaie
Variant: Nouvelle variante de simulation
Stand alone system with batteries
System power: 15.84 kWp
Hay El Quardi - Morocco
PVsyst TRIAL
PVsyst TRIAL
PVsyst V7.2.2
VC0, Simulation date:
21/05/21 21:55
with v7.2.2
Project summary
Geographical Site Situation Project settings
Hay El Quardi Latitude 32.24 °N Albedo 0.20
Morocco Longitude -7.96 °W
Altitude 463 m
PVsyst TRIAL
Time zone UTC
Meteo data
Hay El Quardi
Meteonorm 8.0 (1996-2015), Sat=100 % - Synthétique
System summary
Stand alone system Stand alone system with batteries
PVsyst TRIAL
Oct.-Nov.-Dec.-Jan.-Feb.-Mar.-
System information
PV Array Battery pack
Nb. of modules 44 units Technology Lead-acid, vented, tubular
Pnom total 15.84 kWp Nb. of units 51 units
Voltage 102 V
Capacity 3500 Ah
Results summary
Available Energy 29998 kWh/year Specific production 1894 kWh/kWp/year Perf. Ratio PR 70.79 %
Used Energy 26207 kWh/year Solar Fraction SF 100.00 %
PVsyst TRIAL
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Special graphs 7
PVsyst TRIAL
21/05/21 PVsyst Evaluation mode Page 2/7
Project: romorque solaie
Variant: Nouvelle variante de simulation
PVsyst V7.2.2
VC0, Simulation date:
21/05/21 21:55
with v7.2.2
General parameters
Stand alone system Stand alone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
PVsyst TRIAL
Seasonal tilt adjustment No 3D scene defined Transposition Perez
azimuth 0° Diffuse Perez, Meteonorm
Summer Tilt 19 ° Circumsolar separate
winter 45 °
Oct.-Nov.-Dec.-Jan.-Feb.-Mar.-
User's needs
Daily household consumers
Constant over the year
Average 72 kWh/Day
PV Array Characteristics
PV module Battery
Manufacturer Generic Manufacturer Generic
PVsyst TRIAL
Model JKM 360M-72 Model Adjustable Lead-acid
(Original PVsyst database) Technology Lead-acid, vented, tubular
Unit Nom. Power 360 Wp Nb. of units 51 in series
Number of PV modules 44 units Discharging min. SOC 20.0 %
Nominal (STC) 15.84 kWp Stored energy 285.6 kWh
Modules 22 Strings x 2 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 102 V
Pmpp 14.32 kWp Nominal Capacity 3500 Ah (C10)
U mpp 72 V Temperature Fixed 20 °C
I mpp 200 A
PVsyst TRIAL
Converter Discharging SOC = 0.20 / 0.45
Maxi and EURO efficiencies 97.0 / 95.0 % approx. 99.0 / 102.6 V
Total PV power
Nominal (STC) 16 kWp
Total 44 modules
Module area 85.4 m²
Cell area 75.2 m²
Array losses
Thermal Loss factor DC wiring losses Serie Diode Loss
Module temperature according to irradiance Global array res. 6.0 mΩ Voltage drop 0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 0.9 % at STC
PVsyst TRIAL
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.2.2
VC0, Simulation date:
21/05/21 21:55
with v7.2.2
PVsyst TRIAL
W Hour/day Wh/day
Frigo / Congélateur 1 24 71800
Total daily energy 71800Wh/day
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
21/05/21 PVsyst Evaluation mode Page 4/7
Project: romorque solaie
Variant: Nouvelle variante de simulation
PVsyst V7.2.2
VC0, Simulation date:
21/05/21 21:55
with v7.2.2
Main results
System Production
Available Energy 29998 kWh/year Specific production 1894 kWh/kWp/year
Used Energy 26207 kWh/year Performance Ratio PR 70.79 %
Excess (unused) 2765 kWh/year Solar Fraction SF 100.00 %
PVsyst TRIAL
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 97.9 %
Missing Energy 0 kWh/year Static SOW 90.0 %
PVsyst TRIAL
May 215.9 207.4 2707 394.7 0.000 2226 2226 1.000
June 229.6 215.4 2774 484.4 0.000 2154 2154 1.000
July 232.0 221.0 2792 444.1 0.000 2226 2226 1.000
August 211.2 213.4 2690 345.7 0.000 2226 2226 1.000
September 172.9 188.3 2420 174.8 0.000 2154 2154 1.000
October 142.1 186.1 2428 146.1 0.000 2226 2226 1.000
November 107.3 167.7 2236 0.0 0.000 2154 2154 1.000
December 93.7 160.6 2183 104.0 0.000 2226 2226 1.000
Year 1984.4 2286.4 29998 2764.8 0.000 26207 26207 1.000
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
PVsyst TRIAL
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst V7.2.2
VC0, Simulation date:
21/05/21 21:55
with v7.2.2
Loss diagram
1984 kWh/m² Global horizontal irradiation
+17.8% Global incident in coll. plane
PVsyst TRIAL
-2.17% IAM factor on global
-4.00%
-0.02%
Unused energy (battery full)
PVsyst TRIAL
energy -0.39% Battery Stored Energy balance
0.00% -2.76% Battery efficiency loss
0.0 kWh
-1.87% Charge/Disch. Current Efficiency Loss
-1.28% Gassing Current (electrolyte dissociation)
-0.02% Battery Self-discharge Current
26207 kWh Energy supplied to the user
PVsyst TRIAL
21/05/21 PVsyst Evaluation mode Page 6/7
Project: romorque solaie
Variant: Nouvelle variante de simulation
PVsyst V7.2.2
VC0, Simulation date:
21/05/21 21:55
with v7.2.2
Special graphs
Diagramme d'entrée/sortie journalier
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
21/05/21 PVsyst Evaluation mode Page 7/7