PVsyst - Simulation report
Grid-Connected System

Project: Balachandran-3kW-RT300sqft-335wx9 POLY


Variant: 10 Panel two strings
Sheds on ground
System power: 3300 Wp

PVsyst TRIAL
Padivattam-Balachandran House - India

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: Balachandran-3kW-RT300sqft-335wx9 POLY
Variant: 10 Panel two strings

PVsyst V7.4.6
VC1, Simulation date:
23/03/24 10:58

PVsyst TRIAL
with V7.4.6

Project summary
Geographical Site Situation Project settings
Padivattam-Balachandran House Latitude 10.00 °N Albedo 0.20
India Longitude 76.32 °E
Altitude 7m
Time zone UTC+5.5

Weather data
Padivattam-Balachandran House
Meteonorm 8.1 (1991-2010), Sat=100% - Synthetic

System summary

PVsyst TRIAL
Grid-Connected System Sheds on ground

PV Field Orientation Near Shadings User's needs


Fixed plane Linear shadings : Fast (table) Unlimited load (grid)
Tilt/Azimuth 15 / 0 °

System information
PV Array Inverters
Nb. of modules 10 units Nb. of units 1 unit
Pnom total 3300 Wp Pnom total 3000 W
Pnom ratio 1.100

Results summary
Produced Energy 4778.11 kWh/year Specific production 1448 kWh/kWp/year Perf. Ratio PR 80.59 %

PVsyst TRIAL
Project and results summary

Near shading definition - Iso-shadings diagram


Main results
Loss diagram
Table of contents

General parameters, PV Array Characteristics, System losses


2
3
4
5
6
Predef. graphs 7
Single-line diagram 8

PVsyst TRIAL

PVsyst TRIAL
23/03/24 PVsyst Evaluation mode Page 2/8
Project: Balachandran-3kW-RT300sqft-335wx9 POLY
Variant: 10 Panel two strings

PVsyst V7.4.6
VC1, Simulation date:
23/03/24 10:58

PVsyst TRIAL
with V7.4.6

General parameters
Grid-Connected System Sheds on ground

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon Linear shadings : Fast (table) Unlimited load (grid)

PVsyst TRIAL
PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model Eldora VSP.72.330.05_U Model SUN2000-3KTL-L1
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 330 Wp Unit Nom. Power 3.00 kWac
Number of PV modules 10 units Number of inverters 2 * MPPT 50% 1 unit
Nominal (STC) 3300 Wp Total power 3.0 kWac
Modules 2 string x 5 In series Operating voltage 80-600 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.10
Pmpp 2991 Wp No power sharing between MPPTs
U mpp 171 V
I mpp 18 A

PVsyst TRIAL
Total PV power Total inverter power
Nominal (STC) 3.30 kWp Total power 3 kWac
Total 10 modules Number of inverters 1 unit
Module area 19.4 m² Pnom ratio 1.10

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 163 mΩ Loss Fraction -0.8 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses


Loss Fraction 2.0 % at MPP

IAM loss factor

PVsyst TRIAL
Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
23/03/24 PVsyst Evaluation mode Page 3/8
Project: Balachandran-3kW-RT300sqft-335wx9 POLY
Variant: 10 Panel two strings

PVsyst V7.4.6
VC1, Simulation date:
23/03/24 10:58

PVsyst TRIAL
with V7.4.6

Near shadings parameter


Perspective of the PV-field and surrounding shading scene

PVsyst TRIAL
Iso-shadings diagram
Orientation #1

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
23/03/24 PVsyst Evaluation mode Page 4/8
Project: Balachandran-3kW-RT300sqft-335wx9 POLY
Variant: 10 Panel two strings

PVsyst V7.4.6
VC1, Simulation date:
23/03/24 10:58

PVsyst TRIAL
with V7.4.6

Main results
System Production
Produced Energy 4778.11 kWh/year Specific production 1448 kWh/kWp/year
Perf. Ratio PR 80.59 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² kWh kWh ratio
January 163.7 60.30 27.33 185.7 180.2 508.3 491.3 0.802

PVsyst TRIAL
February 157.8 70.80 28.09 170.3 165.4 466.2 450.8 0.802
March 170.2 92.84 29.10 173.5 167.7 475.4 459.3 0.802
April 162.7 84.67 28.86 158.2 152.5 432.8 417.4 0.800
May 153.2 92.12 28.85 143.4 137.1 395.6 380.5 0.804
June 125.8 79.21 26.53 116.5 111.0 324.8 311.3 0.810
July 122.6 77.51 26.51 114.5 109.0 319.4 305.9 0.810
August 127.9 84.88 26.52 122.9 117.8 343.2 329.5 0.812
September 140.3 89.83 26.65 139.8 134.0 389.7 375.3 0.813
October 142.8 82.77 27.23 149.3 143.8 413.3 398.1 0.808
November 141.5 69.24 27.21 155.6 150.8 430.4 415.2 0.809
December 147.2 66.05 27.63 166.9 161.7 459.3 443.5 0.805
Year 1755.7 950.21 27.54 1796.7 1731.0 4958.6 4778.1 0.806

PVsyst TRIAL
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

PVsyst TRIAL
23/03/24 PVsyst Evaluation mode Page 5/8
Project: Balachandran-3kW-RT300sqft-335wx9 POLY
Variant: 10 Panel two strings

PVsyst V7.4.6
VC1, Simulation date:
23/03/24 10:58

PVsyst TRIAL
with V7.4.6

Loss diagram
1756 kWh/m² Global horizontal irradiation
+2.3% Global incident in coll. plane

-0.80% Near Shadings: irradiance loss

-2.88% IAM factor on global

1731 kWh/m² * 19 m² coll. Effective irradiation on collectors

efficiency at STC = 17.06% PV conversion

PVsyst TRIAL
5722 kWh Array nominal energy (at STC effic.)
-0.61% PV loss due to irradiance level

-10.78% PV loss due to temperature

+0.75% Module quality loss

-2.00% Module array mismatch loss

-1.03% Ohmic wiring loss


4959 kWh Array virtual energy at MPP

-3.43% Inverter Loss during operation (efficiency)

0.00% Inverter Loss over nominal inv. power


0.00% Inverter Loss due to max. input current

PVsyst TRIAL
0.00% Inverter Loss over nominal inv. voltage
-0.03% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
-0.19% Night consumption
4778 kWh Available Energy at Inverter Output
4778 kWh Energy injected into grid

PVsyst TRIAL

PVsyst TRIAL
23/03/24 PVsyst Evaluation mode Page 6/8
Project: Balachandran-3kW-RT300sqft-335wx9 POLY
Variant: 10 Panel two strings

PVsyst V7.4.6
VC1, Simulation date:
23/03/24 10:58

PVsyst TRIAL
with V7.4.6

Predef. graphs
Daily Input/Output diagram

PVsyst TRIAL

PVsyst TRIAL System Output Power Distribution

PVsyst TRIAL

PVsyst TRIAL
23/03/24 PVsyst Evaluation mode Page 7/8
PVsyst V7.4.6

PVsyst TRIAL
VC1, Simulation date:
23/03/24 10:58
with V7.4.6

PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL