You are on page 1of 105

TRƯỜNG ĐẠI HỌC BÁCH KHOA

KHOA CƠ KHÍ
BỘ MÔN CƠ ĐIỆN TỬ

CẢM BIẾN
CÔNG NGHIỆP
(Dành cho sinh viên convenzione
Firma ngành Kỹ thuật Cơ điện tử)
Politecnico diNăm
Milano e Veneranda
học 2022 – 2023
Fabbrica
del Duomo di Milano
Aula Magna – Rettorato
TS.
Mercoledì 27 maggio Đặng Phước Vinh
2015

Email: dpvinh@dut.udn.vn
Chapter 2
Temperature
Sensor Firma convenzione
Politecnico di Milano e Veneranda Fabbrica
del Duomo di Milano
Aula Magna – Rettorato
Mercoledì 27 maggio 2015
3
Content
1. Introduction

2. Thermal Expansion Sensor (Nhiệt kế giãn nở)

3. Resistance Temperature Detectors (Nhiệt kế


điện trở)

4. Thermocouples (Cặp nhiệt ngẫu)

5. Pyrometer (Hỏa kế)

6. Semiconductor-based Temperature Sensors

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


4
Introduction
1. Temperature Scale

2. Measured Temperature

3. Measurement Methods
Temperature sensing is one of the most sensitive properties or parameters for
industries like petrochemical, automotive, aerospace and defense, consumer
electronics, and so on. These sensors are installed into devices with the purpose of
measuring the temperature of a medium accurately and efficiently in a given set of
requirements.

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


5
Introduction
▪ Nhiệt độ là đại lượng vật lý đặc trưng cho
trạng thái nhiệt của vật chất ảnh hưởng rất
lớn đến nhiều tính chất của vật chất đo nhiệt
độ đóng vai trò quan trọng trong công nghiệp
và nhiều lĩnh vực.

▪ Đo nhiệt độ: gián tiếp, dựa vào sự phụ thuộc


của tính chất vật liệu vào nhiệt độ

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


6
Temperature Scale
▪ Setup the suitable temperature scale

▪ Different temperature scales

▪ Three popular scales:


✓ Thermaldynamic temperature Scale (K)
✓ Celsius Scale (C)
✓ Fahrenheit Scale (F)

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


7
Thermaldynamic Scale
▪ Do Thomson Kelvin xây dựng
trên cơ sở định luật nhiệt động
học thứ hai: công trong chu trình
Cacnô tỷ lệ với độ chênh nhiệt độ
chứ không phụ thuộc chất đo
nhiệt độ.
▪ William Thomson, (1824 –
1907) là một nhà vật lý, toán
học, nhà phát minh vĩ đại
người Scotland, là một giáo
sư Đại học Glasgow, Scotland.
Ông được phong tước vị Hoàng
gia Anh là Huân tước KelvinFaculty of Mechanical Engineering
Dr. Dang Phuoc Vinh
8
Thermaldynamic Scale
▪ Điểm chuẩn: điểm tan của nước đá = 273,15 K.

▪ Một độ K bằng độ chênh nhiệt độ ứng với 1%


công trong chu trình Cacnô giữa điểm sôi của
nước và điểm tan của nước đá ở áp suất bình
thường.

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


9
Thermaldynamic Scale
▪ Quan hệ giữa nhiệt độ và công:
Q
T=  100 (K )
Q100 − Q0

▪ Thang đo nhiệt độ tuyệt đối có tính chất thuần


túy lý luận, không thể thể hiện được trên thực tế,
nhưng thống nhất được đơn vị đo nhiệt độ (do
không phụ thuộc chất đo).

PV
▪ Đối với chất khí lý tưởng: T=  100 (K )
P100V100 − PV
0 0

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


10
Celsius Scale
▪ Andreas Celsius (1742)
▪ Unit: ℃
▪ Value:
Melting Ice 0 ℃

Boiling Water 100 ℃
▪ T(℃) = T(K) – 273,15

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


11
Fahrenheit Scale
▪ Fahrenheit (1706)
▪ Unit: ℉
▪ Value:
Melting Ice 32 ℉

Boiling Water 212 ℉

T( F ) =  T ( 0C ) +32
0 9
5
Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering
Fahrenheit was born in 12
Thang đo Fahrenheit Danzig, in the Polish-
Lithuanian Commonwealth,
into a German merchant
family in 1686.

He began training as a
merchant in Amsterdam
after his parents died on
August 14, 1701, when he
was just 15. He later moved
to the Dutch Republic

In 1717, Fahrenheit became


a glassblower, making
barometers, altimeters, and
thermometers.
From 1718 onwards, he
Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering
was a lecturer in chemistry
13
Fahrenheit Scale

One of the original thermometers


made by Daniel Gabriel Fahrenheit
has sold for more than £67,000.

The 300-year-old brass instrument


is one of only three known
examples of Fahrenheit’s work in
existence today.

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


14
Temperature Scale

Kelvin Celsius Fahrenheit


Temperature
(K) (℃) (℉)
Absolute Zero 0 -273 -492
Melting Ice 273 0 32
Boiling Water 373 100 212

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


15

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


16

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


17
Measured Temperature
▪ Nhiệt độ cần đo (𝑇𝑥 ): nhiệt độ
thực của môi trường.
▪ Nhiệt độ đo được (𝑇𝑐 ): nhiệt độ
thu được từ cảm biến.
▪ Xét cảm biến đo tiếp xúc → Sai
số: ∆𝑻 = 𝑻𝒙 − 𝑻𝒄 ≠ 𝟎

Sai số ∆𝑻 phụ thuộc:


- Trao đổi nhiệt giữa cảm biến và môi trường đo.
- Trao đổi nhiệt giữa bộ cảm biến và bên ngoài
Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering
18
Method - Contact
Khi đo, cảm biến tiếp xúc với môi trường đo, phép
đo dựa trên các hiện tượng:
▪ Giãn nở của vật liệu.

▪ Biến đổi trạng thái của vật liệu.

▪ Thay đổi điện trở của vật liệu.

▪ Hiệu ứng nhiệt điện.

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


19
Method – Non Contact
Khi đo cảm biến không tiếp xúc với môi trường
đo, phép đo dựa vào sự phụ thuộc của bức xạ
nhiệt của môi trường đo vào nhiệt độ:
▪ Đo bằng hỏa kế bức xạ.
▪ Đo bằng hỏa kế quang.
▪ Đo bằng hỏa kế hồng ngoại.

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


20
Popular Sensors

Thermal Expansion
Thermocouples
Sensor

Resistance Temperature
Pyrometer
Detectors (RTD)

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


21
Thermal Expansion Sensor

1. Principle

2. Thermal expansion types


a, Metal expansion

b, Fluid expansion

c, Bimetalic

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


22
Principle
Dựa vào sự giãn nở/co lại của vật liệu khi nhiệt
độ tăng/giảm

Hệ số giãn nở [1/độ]

Thể tích Chiều dài


𝑉 𝑡 = 𝑉0 1 + 𝛼𝑣 𝑡 𝑙 𝑡 = 𝑙 0 1 + 𝛼𝑙 𝑡

Giá trị ở 0 ℃

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


23
Metal Expansion

Ceramic – Metal

Metal – Metal

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


24
Ceramic – Metal
▪ Nguyên lý: 𝛼𝑣 𝑡 tăng → ∆𝑇

Thanh gốm giản nở: ∆𝑙𝑔


▪ ൝
Ống kim loại giản nở: ∆𝑙𝑘

▪ ∆𝑙𝑘 > ∆𝑙𝑔 → đầu A của thanh gốm dịch chuyển


sang phải:
∆𝒍 → ∆𝒍𝒌 − ∆𝒍𝒈 = 𝒇(∆𝒕)

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


25
Metal – Metal
Nguyên lý: Khi tăng 1 lượng ∆𝑇 → các thanh giãn nở
với ∆𝑙1 > ∆𝑙2

Do 2 thanh liên kết với nhau → uống cong


→ đầu A dịch chuyển ∆𝑙 = ∆𝑙1 − ∆𝑙2 = 𝑓(∆𝑡)
Đo ∆𝒍 → xác định 𝒕

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


26
Metal Expansion
▪ Feature:
✓ Simple construction
✓ Cheap
✓ Long life

▪ Application:
✓ Range < 700 ℃
✓ Thermal relay

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


27
Thermal Relay
▪ The basic working principle of thermal
relay is that, when a bimetallic strip is
heated up by a heating coil carrying over
current of the system, it bends and makes
normally open contacts.
▪ The bimetallic strips are made of the alloy
of nickel and steel.
▪ When the fault occurs on the system, the
bimetallic spring is heated and getting
bent.
▪ The contact of the relay energizes the trip
circuit because of which the contacts of the
circuit breaker close. Thus, the system
remains safe.
▪ This relay has low overloading
capability. It is designed to operate under
6 ~ 7 times more than the fullFaculty load of Mechanical Engineering
Dr. Dang Phuoc Vinh
current.
28
Thermal Relay

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


29
Thermal Relay

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


30
Applications

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


31
Bimetalic Thermometer
▪ Bimetallic devices take advantage of the
difference in rate of thermal expansion
between different metals.

▪ Strips of two metals are bonded together.


When heated, one side will expand more
than the other, and the resulting bending
is translated into a temperature reading
by mechanical linkage to a pointer.

▪ These devices are portable and they do


not require a power supply, but they are
usually not as accurate as thermocouples
or RTDs and they do not readily lend
themselves to temperature recording

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


32
Bimetalic Thermometer

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


33
Fluid Expansion
▪ Glass housing: ∝𝑡𝑡 = 2 × 10−5 /℃
▪ Liquid: ∝𝐻𝑔 = 18 × 10−5 /℃

▪ Temperature increases ∆𝑡 → liquid


expansion of ∆𝑉 → ∆ℎ
∆𝒉 = 𝒇 ∆𝑽 = 𝒇(∆𝒕)

→ Measure ∆𝒉 can identify 𝒕

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


34
Fluid Expansion
▪ Feature
✓ Simple construction
✓ Cheap
✓ Good accuracy
✓ Do not convert into electrical signal

▪ Application
✓ Range: -50 ÷ 600 ℃
✓ Health

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


35
Liquid-in-glass

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


36

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


37
RTD (Nhiệt kế điện trở)
1. Principle
2. RTD Types

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


38
Principle
▪ RTD: Resistance Temperature Detectors

▪ Resistance changes with temperature: The resistance


increases as the temperature of the sensor increases.

▪ External electronic devices are used to measure the


resistance of the sensor by passing a small electrical
current through the sensor to generate a voltage

𝑹(𝑻) = 𝑹𝟎 𝒇 𝑻 − 𝑻𝟎

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


39
RTD vs. Temperature

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


40
2 popular kinds of RTD

RTD with Head and Terminal RTD with Metal Wire


Đầu củ hành Dạng dây

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


41
Construction of RTD

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


42
RTD with Head

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


43
RTD with Head

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


44
RTD Application

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


45
RTD Application

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


46
Pt100
• RTD cũng được gọi là điện trở nhiệt bao gồm các loại
Pt100, Pt500, Pt1000, Ni100, Ni500.

• 2 loại chính thường dùng trong công nghiệp đo là


loại Pt100 và Ni100.

Pt100

Platinum
ở 0 °C → R = 100 Ohm
(bạch kim)

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


47
Pt100: R vs. T

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


48
Pt100: R vs. T

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


49
2, 3, 4 – Wire RTD

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


50
2 – wire RTD

R đo = R W1 + R W2 + R

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


51
3 – wire RTD

Rđo = Rw3 – Rw1 + R


Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering
52
4 – wire RTD

Rđo = R

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


53
4 – wire RTD

A constant current is passed through L1 and L4


L2 and L3 measure the voltage drop across the RTD

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


54
RTD measurement device

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


55
RTD measurement device

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


56
RTD measurement device

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


57
Self-Heating
▪ To measure resistance, it is necessary to pass a current through
the RTD.
▪ The resultant voltage drop across the resistor heats the device
in an effect known as the 𝐈 𝟐 𝐑, or Joule heating.
▪ The sensor's indicated temperature is therefore slightly higher
than the actual temperature.
▪ The amount of self-heating also depends heavily on the
medium in which the RTD is immersed.
▪ An RTD can self-heat up to 100x higher in still air than in
moving water, so self-heating specifications are just a
conservative guide.

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


58
2, 3, & 4 - Wire RTD

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


59
2, 3, & 4 - Wire RTD

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


60
2, 3, & 4 - Wire RTD

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


61
2, 3, & 4 - Wire RTD

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


62
Notes from manufacturer
▪ When calibrating the resistance of an RTD, use a 4-wire connection, if
possible.
▪ When you calibrate an RTD temperature transmitter that is configured
for 3-wire measurement, you need to use 3 wires. Make sure you use 3
similar wires and that you make good contacts.
▪ When using a 3-wire RTD probe in process, connected to an RTD
transmitter, make sure you make good contacts to the transmitter
screws for all 3 wires.
▪ When using a RTD reference probe in calibration, make sure you
always use a 4-wire connection.
▪ Never use 2-wire resistance measurement for anything that you need
to be accurate. Sure, it can be used for troubleshooting and for rough
measurements. https://blog.beamex.com/resistance-
measurement-2-3-or-4-wire-connection

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


63
Long Distance

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


64
Seneca T120
▪ Loại 2 dây: 1 dây vào chân 1
hoặc 2, dây còn lại vào chân
3 hoặc 4.
▪ Loại 3 dây: 2 dây cùng màu
nối vào chân 3 và chân 4, dây
khác màu nối vào chân 1

▪ Loại 4 dây: 2 dây cùng màu vào


chân 1,2; 2 dây cùng màu còn
lại vào chân 3,4.
Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering
65
Seneca T120

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


66
Thermocouple (Cặp nhiệt ngẫu)

1. Thermoelectric Effect

2. Material

3. Construction

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


67
Thermoelectric Effect
Thermoelectric effect (Peltier effect;
Seebeck effect; Thomson effect)

The thermoelectric effect is the direct conversion


of temperature differences to electric voltage and
vice versa via a thermocouple

Sự chênh lệch nhiệt độ giữa hai vật dẫn điện khác


bản chất được kết nối với nhau sẽ tạo nên một
hiệu điện thế và ngược lại

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


68
Thermoelectric Effect
▪ Xét một mạch kín gồm 2 dây dẫn (A) và (B)
khác nhau về bản chất hóa học hàn nối với
nhau bằng các mối hàn

▪ Khi nhiệt độ hai mối hàn là (t) và (𝑡0 ) khác


nhau thì trong mạch xuất hiện một sức điện
động 𝐸𝐴𝐵 phụ thuộc độ chênh nhiệt độ giữa
hai mối hàn

→ Hiệu ứng nhiệt điện

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


69

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


70
Thermoelectric Effect

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


71
Thermoelectric Effect

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


72
Thermocouple

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


73
Thermocouple

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


74
Material
Yêu cầu vật liệu chế tạo:
▪ Sức điện động đủ lớn (để dễ dàng chế tạo dụng cụ
đo thứ cấp).
▪ Có đủ độ bền cơ học và hoá học ở nhiệt độ làm
việc.
▪ Dễ kéo sợi.
▪ Có khả năng thay lẫn.
▪ Giá thành rẽ.
Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering
75
Material

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


76
Construction

1. Vỏ bảo vệ 5. Bộ phận lắp đặt


2. Mối hàn 6. Vít nối dây
3. Dây cực 7. Dây nối
4. Sứ cách điện 8. Đầu nối dây
Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering
77
Thermocouple - K
▪ Là loại thermocouple được sử dụng phổ biến nhất trong các
ngành công nghiệp.
▪ Là một thiết bị cảm biến nhiệt điện mạch kín bao gồm hai dây
kim loại khác nhau được nối lại ở cả hai đầu.
▪ Một dòng điện được tạo ra khi nhiệt độ ở một đầu khác với nhiệt
độ ở đầu còn lại.
▪ Thang đo: -270 ℃ ~ 1372 ℃

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


78
Thermocouple - K

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


79
Thermocouple - K

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


80
Thermocouple - K

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


81
Thermocouple

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


82
Thermocouple - K

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


83
TC Application

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


84
RTD vs. TC

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


85
Pyrometer (Hỏa kế)
1. Radiation Pyrometer (Hỏa kế bức xạ)

2. Optical Pyrometer (Hỏa kế quang)

3. IR Pyrometer (Hỏa kế hồng ngoại)


• Các vật mang nhiệt sẽ có hiện tượng bức xạ năng lượng.
• Năng lượng bức xạ sẽ có một bước sóng nhất định.
• Hỏa kế sẽ thu nhận bước sóng này và phân tích để cho ra nhiệt độ của
vật cần đo.

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


86
Electromagnetic Spectrum

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


87
Radiation Pyrometer
Priciple: Năng lượng bức xạ toàn phần của vật đen
tuyệt đối tỉ lệ với luỹ thừa bậc 4 của nhiệt độ tuyệt
đối của vật:
𝑬 = 𝝈𝑻𝟒 (𝜎 là hệ số bức xạ)

1. Nguồn bức xạ 2. Thấu kính hội tụ 3. Gương phản xạ


Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering
4. Bộ phận thu năng lượng 5. Dụng cụ đo thứ cấp
88
Construction

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


89
Features
▪ Đo không tiếp xúc → giảm nhẹ điều kiện lao
động.
▪ Đo được nhiệt độ cao > 1000 ℃, sai số ±27 ℃.
✓ Loại hội tụ tổn thất năng lượng lớn (30 - 40%) nhưng
ít chịu ảnh hưởng của bụi và ẩm.
✓ Loại phản xạ tổn thất năng lượng bé (~10%) nhưng
chịu ảnh hưởng lớn của bụi và ẩm.

▪ Khoảng cách đo tốt nhất là 1 ± 0,2 m.

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


90
Application

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


91
Optical Pyrometer (Hỏa kế quang)
▪ Thiết bị này theo dõi và đo độ lớn thực tế của bức xạ
nhiệt tỏa ra từ đối tượng cần đo.
▪ Bức xạ nhiệt tỏa ra từ đối tượng sẽ đi qua 1 hệ thống
quang học bên trong pyrometer.
▪ Hệ thống quang học sẽ làm cho bức xạ nhiệt hội tụ tốt
hơn và đi qua đầu dò.
▪ Đầu ra của đầu dò sẽ tỉ lệ với bức xạ nhiệt đầu vào.
▪ Ưu điểm: không có sự tiếp xúc trực tiếp giữa pyrometer
và đối tượng phát ra nhiệt.

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


92
Principle
Principle: based on Plank’s law
C1 𝑰λ𝑻 : cường độ bức xạ đơn sắc ứng
I T = với bước sóng λ ở nhiệt độ T (K).
 C2

  e RT − 1 R: hằng số khí lý tưởng.
5

  C1, C2: Hằng số.

Hai vật có độ sáng ứng với


một bước sóng nhất định
bằng nhau thì có nhiệt độ
bằng nhau

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


93
Construction
5 4

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


94
Construction
1. Một mắt kính (quan sát) ở bên trái và một thấu kính
quang học ở bên phải.
2. Một bóng đèn tham chiếu (bóng đèn mẫu), được cấp
nguồn bởi pin.
3. Một biến trở để thay đổi dòng điện và từ đó thay đổi
cường độ sáng.
4. Để tăng dải nhiệt độ đo được, một màn ngăn được lắp
ráp giữa thấu kính quang học và bóng đèn tham chiếu.
5. Một tấm lọc màu đỏ đặt giữa kính mắt và sóng đèn tham
chiếu giúp thu hẹp dải của bước sóng ánh sáng.

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


95
Method
▪ Khi đo hướng ống kính về phía vật đo và đóng khóa (K) cấp
điện nung dây tóc bóng đèn mẫu.
▪ Điều chỉnh biến trở 𝑅𝑏 để điều chỉnh nhiệt độ dây tóc cho
đến khi độ sáng của dây tóc bóng đèn bằng độ sáng của vật.

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


96
Features
▪ Đo không tiếp xúc
▪ Kết quả đo phụ thuộc vào khả
năng nhận xét màu
▪ Ảnh hưởng của khoảng cách đo
nhỏ
▪ Phép đo dựa vào cường độ ánh
sáng nên thiết bị chỉ có thể đo
nhiệt độ thấp nhất là 700 ℃.
▪ Thiết bị không khả dụng để thu
các giá trị liên tục của nhiệt độ
tại khoảng nhỏ.
Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering
97
IR Pyrometer
▪ Cấu tạo: Làm từ mạch điện tử, quang học.
▪ Nguyên lý: Đo tính chất bức xạ năng lượng của môi trường
mang nhiệt.
▪ Ưu điểm: Dùng trong môi trường khắc nghiệt, không cần tiếp
xúc với môi trường đo.
▪ Khuyết điểm: Độ chính xác không cao, đắt tiền.
▪ Ứng dụng: Làm các thiết bị đo cho lò nung.
▪ Dải đo: -97 oC ~ 1800 oC

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


98

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


99

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


100
IR Pyrometer

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


101
IR Pyrometer

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


102
Hỏa kế hồng ngoại

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


103
IR Pyrometer

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


104
IR Pyrometer

Dr. Dang Phuoc Vinh Faculty of Mechanical Engineering


the END !
Firma convenzione
Politecnico di Milano e Veneranda Fabbrica
del Duomo di Milano
Aula Magna – Rettorato
Mercoledì 27 maggio 2015

You might also like